Control or indicatorReset switchAlarm LEDTrouble LEDPower LEDDescriptionSensor controls and indicatorsMagnetictest/resetswitchResets the sensor when it is in thealarm or trouble state. Activates ortests the sensor when it is in thenormal state.Indicates one or both sensors are inthe alarm stateIndicates one or both sensors are inthe trouble state (flashing = dirty fault,steady = internal or wiring fault)Indicates the controller is energizedAlarmTroubleFigure 5: Sensor controls and indicatorsPowerDirtyThe controls and indicators on the four-wire smoke sensor (seeFigure 5) are described in the table below.Control or indicatorMagnetic test/resetswitchAlarm LEDTrouble LEDDirty LEDPower LEDNormal stateDescriptionResets the sensor when it is in thealarm or trouble state. Activates ortests the sensor when it is in thenormal state.Indicates the sensor is in the alarmstateIndicates the sensor is in the troublestateIndicates the amount of environmentalcompensation used by the sensor(flashing continuously = 100%)Indicates the sensor is energizedThe <strong>Super<strong>Duct</strong></strong> duct smoke detector operates in the normalstate in the absence of any trouble conditions and when itssensing chamber is free of smoke. In the normal state, thePower LED on both the sensor and the controller are on andall other LEDs are off.Alarm stateThe <strong>Super<strong>Duct</strong></strong> duct smoke detector enters the alarm statewhen the amount of smoke in the sensor’s sensing chamberexceeds the alarm threshold value. Upon entering the alarmstate:• The sensor’s Alarm LED and the controller’s Alarm LEDturn on• The contacts on the controller’s two auxiliary relayschange over• The controller’s alarm initiation relay closes• The controller’s remote alarm LED output is activated(turned on)• The controller’s high impedance multiple fan shutdowncontrol line is pulled to groundTrouble stateThe <strong>Super<strong>Duct</strong></strong> duct smoke detector enters the trouble stateunder the following conditions:• A sensor’s cover is removed and 20 minutes pass before itis properly secured• A sensor’s environmental compensation limit is reached(100% dirty)• A wiring fault between a sensor and the controller isdetected• An internal sensor fault is detectedUpon entering the trouble state:• The contacts on the controller’s supervisory relay changeover• If a sensor trouble, the sensor’s Trouble LED and thecontroller’s Trouble LED turn on• If 100% dirty, the sensor’s Dirty LED turns on and thecontroller’s Trouble LED flashes continuously• If a wiring fault between a sensor and the controller, thecontroller’s Trouble LED turns on but not the sensor’sNote: All troubles are latched by the duct smoke detector. Youmust clear the trouble condition then reset the duct smokedetector in order to restore it to the normal state.Multiple duct detector operationThe interconnect feature of the <strong>Super<strong>Duct</strong></strong> duct smoke detectorlets you connect up to 15 <strong>Super<strong>Duct</strong></strong> duct smoke detectors toeach other, typically for multiple fan shutdown applications.Technical Bulletin6 <strong>Super<strong>Duct</strong></strong> <strong>Four</strong>-<strong>Wire</strong> <strong>Duct</strong> <strong>Smoke</strong> <strong>Detector</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!