SPECIFICATIONSFunctional SpecificationsAdjustments/SettingsOvercurrentUnderload (dry-well)OvervoltageUndervoltageNumber of restarts allowed in 60second period (rapid-cycling)Trip Delay TimesOvercurrentDry-wellRestart Delay TimesOver/undervoltageAll other faultsInput CharacteristicsSupply VoltageLoad RangeFrequencyOutput CharacteristicsOutput Contact Rating-SPSTGeneral CharacteristicsAmbient Operating TemperatureMaximum Input PowerWire GaugeTerminal TorqueStandards PassedElectrostatic Discharge (ESD)Surge Immunity125% of calibration pointAdjustable (70-90% of calibrated run power)265VAC190VAC45 seconds4 seconds2 secondsManual, 2-225 minutes230VAC5 to 15hp (external current transformer required)50/60 Hz (note: 50Hz will increase all delay timers by20%)720VA @ 240VAC-40° to 55°C (-40° to 131°F)5 WSolid or stranded 10 - 22AWG13 in.-lbs.IEC 61000-4-2, Level 2, 4kV contact, 6kV airIEC 61000-4-5, Level 4, 4kV line-to-line and line-togroundSafety MarksULC Listed UL508, C22.2 No. 14Dimensions2.90” H x 5.26” W x 2.93” DWeight14 oz.Mounting Methods#8 screws© 2009 <strong>SymCom</strong>, Inc. All Rights Reserved 10