10.07.2015 Views

High-Performance Micro-D Connectors and Cables - Pan Pacific ...

High-Performance Micro-D Connectors and Cables - Pan Pacific ...

High-Performance Micro-D Connectors and Cables - Pan Pacific ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Micro</strong>-DHarnessMWDM <strong>Micro</strong>-DShielded Cable AssembliesBSingle-Ended or Double-Ended–These easy-to-order cableassemblies eliminate the need for expensive assembly labor.100% tested <strong>and</strong> ready for use.Now With Twisted Pairs–No need to create a procurementspecification for <strong>Micro</strong>-D cables with twisted pairs. Glenair177-740 cables are furnished with a full complement of white/blue twisted pair wires.Integral Shield Termination–The connector shell has aplatform to accept B<strong>and</strong>-It shield termination b<strong>and</strong>s. Thecable shield braid is attached directly to the connector.Save Labor, Reduce Weight <strong>and</strong> Improve EMI Shielding with Glenair’s<strong>Micro</strong>-D Shielded Cable AssembliesAerospace electronics systems require higher <strong>and</strong> higher levels of protection from radiated emissions. Glenair’sfully shielded <strong>Micro</strong>-D cable assemblies meet this need. The cable shield is attached directly onto the one-piececonnector shell <strong>and</strong> secured with a stainless steel BAND-IT® clamp. These pre-wired, 100% tested assembliesmeet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low shell-toshellresistance. Available with a variety of wire types <strong>and</strong> shields, <strong>Micro</strong>-D shielded assemblies can be ordered inany length, either single-ended or “back-to-back”.Ground Spring <strong>and</strong> EMI Shielding Effectiveness – A gold-platedstainless steel ground spring on the pin connector mating face offerssubstantial improvement in EMI protection. The graphs compareidentical connectors tested with <strong>and</strong> without ground springs.EMI <strong>Performance</strong> with Ground SpringEMI <strong>Performance</strong> without Ground SpringSHIELDING EFFECTIVENESS (Db)10090807060504030201001.00E+03 1.00E+04 1.00E+05 1.00E+06 1.00E+07 1.00E+08 1.00E+09SHIELDING EFFECTIVENESS (Db)10090807060504030201001.00E+03 1.00E+04 1.00E+05 1.00E+06 1.00E+07 1.00E+08 1.00E+09frequency (Hz)frequency (Hz)© 2011 Glenair, Inc. U.S. CAGE Code 06324Printed in U.S.A.GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912www.glenair.comB-8E-Mail: sales@glenair.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!