<strong>Chromatography</strong>Syringes/Microlitre SyringesLLG CHROMATOGRAPHY CATALOGUE11Syringe TerminationsSyringe terminations are offered in a number of different configurations designed toHamiltonaccommodate a broad range of applications. From cemented to removable needles, andluer taper /PTFE luer-lock to special syringe fittings, syringe barrel terminations serve a key function at the interfaceof a syringe and its mating connection.N, NR (Cemented Needle, Rheodyne)Needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark.NR stands for syringes with Rheodyne specified needles.LTN (Luer Tip Cemented Needle)Needles are cemented into the conical glass luer tip of the barrel at a point corresponding to the zero graduation mark.SN (Special Needle)Hamilton offers customized syringes with special needles. State the following details: needle length, gauge, point style,and whether electro-tapered. Example of a correct specification: 701 SN, 70mm, gauge 25, point style 3,not electrotapered. Without these details the corresponding standard syringe 701 N will be supplied.RN (Removable Needle)Removable needles seat precisely to the zero graduation mark of the syringe. Allows the use of different specificationneedles on the same syringe barrel.LT (Luer Tip)Ground glass syringe barrel with a male luer taper accepts most hypodermic needles. Use Kel-F hub needles andconnectors for a tight seal.KH (Knurled Hub)Removable needle, knurled hub is used on 7000 Series syringes, exclusively. The attachment of a spacer enablesrepeatable depth injections.C (Cheminert)1/4"-28 UNF, male fitting. Used in low volume applications where system dead volumes need to be minimized.TLL, TLLX (PTFE Luer-Lock)Male luer taper with nickel-plated brass hub accepts, and locks in place, luer hub needles and connectors.The X-style plunger stop incorporates a 6-32 UNC female thread on the end of the stop to allow attachment to drivearm mechanisms, such as on the Microlab 500 Series diluters/dispensers.AD (AccuDil ® )M8 x 0.75, male fitting. Used with Microlab 1000 PLUS diluter/dispenser.DAD (Diluter AccuDil ® )M8 x 0.75 male fitting with M6 x 1 side port. Used with Microlab 1000 Plus diluter/dispenser.SL (SampleLock)On/Off syringe valve with RN needle is cemented to a syringe barrel. Used for headspace, environmental samplecollection and storage, pre-pressurization of gaseous samples for GC analysis, and sample spiking.22Microlitre syringes, Needle TypesPoint Style 2 (pst2): 12° bevelled non-coring needle point recommended for septum penetration.Ideal for gas chromatographic applications.HamiltonPoint Style 3 (pst3): Blunt needle point (90°) for use with HPLC injection valves. Also recommended for applicationswhere exact dosing is required (e.g. thin layer chromatographs).Point Style 4 (pst4): 10-12° bevelled needle point recommended for life science applications; sharp point foranimal injection.Point Style 5 (pst5): Conical needle with side port for penetration of septa, thin-gauged vinyls and plastics withoutcoring; minimizes septum damagePoint Style AS (pstAS): Special conical style needle point (8° taper) designed to withstand the demands of multipleinjections; exclusively used on GC autosampler syringes34E & OE.
LLG CHROMATOGRAPHY CATALOGUE<strong>Chromatography</strong>Syringes/Microlitre Syringes1Microlitre syringes, 700 series, with fixed needleWith fixed needle (N, NR). NR stands for syringes with Rheodyne specified needles.Plungers are individually fitted, therefore cannot be interchanged and are not availableas replacement parts. Needles are electro-tapered.Hamilton1Needle length51mmType Capacity Gauge Point style PK Cat. No.µl75 N701 N701 N702 N705 N710 N725 N750 N75 N701 N702 NR705 NR710 NR725 NR750 N510102550100250500510255010025050026s26s26s22s22s22s22s22s26s26s22s22s22s22s22s2 (GC)2 (GC)2 (GC)2 (GC)2 (GC)2 (GC)2 (GC)2 (GC)3 (HPLC)3 (HPLC)3 (HPLC)3 (HPLC)3 (HPLC)3 (HPLC)3 (HPLC)1161111111111119.221 0019.221 0029.221 0109.221 0039.221 0049.221 0059.221 0069.221 0079.221 0119.221 0129.221 0139.221 0149.221 0159.221 0166.055 335Microlitre syringes, 700 series, for removable needles- 5µl - 500µl- For use with liquids- Removable needles (RN9, or luer tip (LT)- Plungers and Syringe barrels are not interchangeable or replaceable- Tight tolerances between the plunger and the barrelNeedle length51mmPoint style2 (GC)HamiltonType Capacity Gauge Point style PK Cat. No.µl75 RN701 RN701 RN702 RN705 RN710 RN725 RN750 RN701 LT*702 LT*705 LT*710 LT*725 LT*750 LT*51010255010025050010255010025050026s26s26s22s22s22s22s22s26s22s22s22s22s22s2 (GC)2 (GC)2 (GC)2 (GC)2 (GC)2 (GC)2 (GC)2 (GC)116111111111119.221 0809.221 0816.059 8999.221 0829.221 0839.221 0849.221 0859.221 0869.221 0219.221 0229.221 0239.221 0249.221 0259.221 026* Needle - please order separately.4Needles for RN syringesRemovable. Not for use in HPLC applications.Length51mmPoint style 223Hamilton2349.221 0819.221 021Type7758-027758-037779-017779-03Ext.diam.mm0.50.70.70.7Int.Diam.Gauge Volume PK Cat. No.mm0.13 26s2,5 µl - 100 µl6 9.221 6920.15 22s2,5 µl - 100 µl6 9.221 6930.41 22s250 µl - 10 ml6 9.221 6940.15 22s250 µl - 10 ml6 9.221 695E & OE.35
- Page 2 and 3: perfectly together!Product choice
- Page 4 and 5: Alphabetical indexLLG CHROMATOGRAPH
- Page 6 and 7: ChromatographyVials/Ampoules, Septa
- Page 8 and 9: ChromatographyVials/Ampoules, Septa
- Page 10 and 11: ChromatographyVials/Ampoules, Septa
- Page 12 and 13: ChromatographyVials/Ampoules, Septa
- Page 14 and 15: ChromatographyVials/Ampoules, Septa
- Page 16 and 17: ChromatographyVials/Ampoules, Septa
- Page 18 and 19: ChromatographyVials/Ampoules, Septa
- Page 20 and 21: ChromatographyVials/Ampoules, Septa
- Page 22 and 23: ChromatographyVials/Ampoules, Septa
- Page 24 and 25: ChromatographyVials/Ampoules, Septa
- Page 26 and 27: ChromatographyVials/Ampoules, Septa
- Page 28 and 29: ChromatographyVials/Ampoules, Septa
- Page 30 and 31: ChromatographyVials/Ampoules, Septa
- Page 32 and 33: ChromatographyVials/Ampoules, Septa
- Page 34 and 35: perfectly together!Product choice
- Page 38 and 39: ChromatographySyringes/Microlitre S
- Page 40 and 41: ChromatographySyringes/Microlitre S
- Page 42 and 43: Microliter SyringesFor Chromatogra
- Page 44 and 45: ChromatographySample preparation/SP
- Page 46 and 47: ChromatographySample preparation/SP
- Page 48 and 49: ChromatographySample preparation/SP
- Page 50 and 51: ChromatographySample preparation/SP
- Page 52 and 53: ChromatographySample preparation/SP
- Page 54 and 55: ChromatographySample preparation/Sy
- Page 56 and 57: ChromatographySample preparation/Sy
- Page 58 and 59: ChromatographyChromatography column
- Page 60 and 61: ChromatographyChromatography column
- Page 62 and 63: ChromatographyChromatography column
- Page 64 and 65: ChromatographyChromatography column
- Page 66 and 67: ChromatographyChromatography column
- Page 68 and 69: ChromatographyChromatography column
- Page 70 and 71: ChromatographyChromatography column
- Page 72 and 73: ChromatographyChromatography column
- Page 74 and 75: ChromatographyChromatography column
- Page 76 and 77: ChromatographyChromatography column
- Page 78 and 79: ChromatographyChromatography column
- Page 80 and 81: ChromatographyChromatography column
- Page 82 and 83: ChromatographyChromatography column
- Page 84 and 85: ChromatographyChromatography column
- Page 86 and 87:
ChromatographyChromatography column
- Page 89 and 90:
LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 91 and 92:
LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 93 and 94:
LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 95 and 96:
LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 97 and 98:
LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 99 and 100:
LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 101 and 102:
LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 103 and 104:
LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 105 and 106:
LLG CHROMATOGRAPHY CATALOGUEReady-t
- Page 107 and 108:
LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 109 and 110:
LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 111 and 112:
LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 113 and 114:
Notes111