<strong>Chromatography</strong><strong>Chromatography</strong> columns/GC columnsLLG CHROMATOGRAPHY CATALOGUE11Optima ® 1701 capillary columns for GC14 % Cyanopropyl-phenyl - 86 % DimethylpolysiloxaneMACHEREY-NAGELUSP G46medium polar phasespecial selectivity due to high cyanopropyl contentreference column for structure identification, e.g. in combination with Optima 5film thickness 1 µm for solvent analysessimilar phases: OV-1701, DB-1701, CP?Sil 19 CB, HP-1701, Rtx-1701, SPB-1701, 007-1701, BP10, ZB-1701max. temperature for isothermal operation: 300°C, max. temperature for short isotherms in a temperature programme:320°C for 0.53mm ID columns the max. temperatures are 280 and 300°C, resp.Int.Ext. Film Length PK Cat. No.diam.diam. thicknessmm mm µm m0.250.250.250.250.250.250.250.320.320.320.320.320.320.320.320.320.320.320.320.320.320.320.320.530.530.530.530.530.40.40.40.40.40.40.40.50.50.50.50.50.50.50.50.50.50.50.50.50.50.50.50.80.80.80.80.80.250.250.501.000.250.250.500.250.350.501.000.250.350.501.000.250.351.001.000.250.350.501.001.002.001.002.002.002530303050606025252525303030305050505060606060252530305011111111111111111111111111114.003 0354.003 0364.003 0394.003 2724.003 0374.003 0384.003 0404.003 1034.003 2224.003 1074.003 2684.003 1044.003 2234.003 1084.003 2694.003 1054.003 2244.003 1094.003 2704.003 1064.003 2257.088 3274.003 2714.003 1724.003 1784.003 1734.003 1794.003 180Custom-made columns to your specifications on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa, and thus protected from Additionally, we supply the corresponding test mixture with each column.Analysis of aromatic hydrocarbonsColumn: OPTIMA ® 1701, 0.25 μm film, 25 m x 0.32 mm ID, max. temp. 300/320 °CInj. volume: 1 μlCarrier gas: 0.6 bar N 2Split: 1:40Temperature: 60 °C → 120 °C, 4 °C/minDetector: FID 260 °CPeaks:1. Benzene7. 2-Methylphenol2. Toluene8. 2,6-Dimethylphenol3. Ethylbenzene9. 4-Methylphenol4. p-Xylene10. 2,4-Dimethylphenol5. o-Xylene11. 2,4,6-Trimethylphenol6. PhenolMN Appl. No. 200400214350 56 789101110 15 min92E & OE.
LLG CHROMATOGRAPHY CATALOGUE<strong>Chromatography</strong><strong>Chromatography</strong> columns/GC columns1Optima ® 624 capillary columns for GC6% cyanopropyl-phenyl - 94% dimethylpolysiloxaneMACHEREY-NAGEL1USP G43medium polar phaserecommended for environmental analysessimilar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOLmax. temperature for isothermal operation: 280°C,max. temperature for short isotherms in a temperature programme: 300°CInt.Ext. Film Length PK Cat. No.diam.diam. thicknessmm mm µm m0.250.250.250.250.320.320.530.530.40.40.40.50.50.50.80.81.401.401.401.801.801.803.003.003050603050602530111111114.003 2114.003 2124.003 2134.003 2174.003 2184.003 2194.003 2204.003 221Custom-made columns to your specifications avaialble on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa. Additionally, we supply the corresponding test mixture with each column.2Optima ® 624 LB capillary columns for GC6% cyanopropyl-phenyl - 94% dimethylpolysiloxaneMACHEREY-NAGEL2USP G 43medium polar phaselow bleed columns for halogenated hydrocarbons, volatiles, aromatic compounds, solvents etc.similar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOLmax. temperature for isothermal operation: 280°C,max. temperature for short isotherms in a temperature programme: 300°CInt.Ext. Film Length PK Cat. No.diam.diam. thicknessmm mm µm m0.320.320.50.51.801.803050114.003 2144.003 215Custom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa. Additionally, we supply the corresponding test mixture with each column.Solvents and semi-volatilesColumn: OPTIMA ® 624 LB, 1.8 μm film, 30 m x 0.32 mm ID; Retention Gap Phe-Sil 0.5 m x 0.53 mmCarrier gas: 1.1 bar He1Temperature: 45 °C (3 min) → 150 °C (6 °C/min) →14 15 17300 °C (18 °C/min), 20 min 300 °CInjection: 1 μl (10 ppm per substance in acetone),cold on-column8Detection: FID 280 °C13 16Peaks:1. Acetone11. Decane72. Ethyl acetate 12. Octanol-111 123. Tetrahydrofuran 13. Acetophenone4. Cyclohexane 14. Butyrophenone4 565. Methyl-2-butanol-2 15. Heptanophenone6. Butanol-116. Methoxy-5-indole2 37. Pyridine17. Dibenzylamine9 108. Toluene18. Methyl eicosanoate9. Dimethylformamide 19. Methyl cis-13-docosenoate10. Dimethylsulphoxide 20. Methyl docosanoate181920MN Appl. No. 212520 0 10 20 30 40 minE & OE.93
- Page 2 and 3:
perfectly together!Product choice
- Page 4 and 5:
Alphabetical indexLLG CHROMATOGRAPH
- Page 6 and 7:
ChromatographyVials/Ampoules, Septa
- Page 8 and 9:
ChromatographyVials/Ampoules, Septa
- Page 10 and 11:
ChromatographyVials/Ampoules, Septa
- Page 12 and 13:
ChromatographyVials/Ampoules, Septa
- Page 14 and 15:
ChromatographyVials/Ampoules, Septa
- Page 16 and 17:
ChromatographyVials/Ampoules, Septa
- Page 18 and 19:
ChromatographyVials/Ampoules, Septa
- Page 20 and 21:
ChromatographyVials/Ampoules, Septa
- Page 22 and 23:
ChromatographyVials/Ampoules, Septa
- Page 24 and 25:
ChromatographyVials/Ampoules, Septa
- Page 26 and 27:
ChromatographyVials/Ampoules, Septa
- Page 28 and 29:
ChromatographyVials/Ampoules, Septa
- Page 30 and 31:
ChromatographyVials/Ampoules, Septa
- Page 32 and 33:
ChromatographyVials/Ampoules, Septa
- Page 34 and 35:
perfectly together!Product choice
- Page 36 and 37:
ChromatographySyringes/Microlitre S
- Page 38 and 39:
ChromatographySyringes/Microlitre S
- Page 40 and 41:
ChromatographySyringes/Microlitre S
- Page 42 and 43:
Microliter SyringesFor Chromatogra
- Page 44 and 45: ChromatographySample preparation/SP
- Page 46 and 47: ChromatographySample preparation/SP
- Page 48 and 49: ChromatographySample preparation/SP
- Page 50 and 51: ChromatographySample preparation/SP
- Page 52 and 53: ChromatographySample preparation/SP
- Page 54 and 55: ChromatographySample preparation/Sy
- Page 56 and 57: ChromatographySample preparation/Sy
- Page 58 and 59: ChromatographyChromatography column
- Page 60 and 61: ChromatographyChromatography column
- Page 62 and 63: ChromatographyChromatography column
- Page 64 and 65: ChromatographyChromatography column
- Page 66 and 67: ChromatographyChromatography column
- Page 68 and 69: ChromatographyChromatography column
- Page 70 and 71: ChromatographyChromatography column
- Page 72 and 73: ChromatographyChromatography column
- Page 74 and 75: ChromatographyChromatography column
- Page 76 and 77: ChromatographyChromatography column
- Page 78 and 79: ChromatographyChromatography column
- Page 80 and 81: ChromatographyChromatography column
- Page 82 and 83: ChromatographyChromatography column
- Page 84 and 85: ChromatographyChromatography column
- Page 86 and 87: ChromatographyChromatography column
- Page 89 and 90: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 91 and 92: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 93: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 97 and 98: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 99 and 100: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 101 and 102: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 103 and 104: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 105 and 106: LLG CHROMATOGRAPHY CATALOGUEReady-t
- Page 107 and 108: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 109 and 110: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 111 and 112: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 113 and 114: Notes111