<strong>Chromatography</strong><strong>Chromatography</strong> columns/Flash columnsLLG CHROMATOGRAPHY CATALOGUE11CHROMABOND ® Flash cartridges for Biotage ® systemsProduct range designed for use in Flash systems of Biotage AB (Flash 12i and FlashMaster)without additional connectors or capillaries.on request all column types listed below can be packed with any CHROMABOND ® adsorbent(please note that other packings often result in differing adsorbent weights).CHROMABOND ® Flash RS columns for Teledyne Isco ® systems (RS) on request.MACHEREY-NAGELDescriptionFlash FM 15/2 SiOHFlash FM 25/5 SiOHFlash FM 25/10 SiOHFlash FM 70/10 SiOHFlash FM 70/20 SiOHFlash FM 70/25 SiOHFlash FM 150/25 SiOHFlash FM 150/50 SiOHFlash FM 150/70 SiOHFlash FM 15/2 C18 ecFlash FM 25/5 C18 ecFlash FM 70/10 C18 ecFlash FM 150/50 C18 ecFlash FM 70/10 NH2Flash FM 70/20 NH2Column Int. Capacity PK Cat. No.Length diam.cm mm g9.0 15.80 2.050 4.003 78510.0 20.50 5.050 4.003 79210.0 20.50 10.050 4.003 69315.4 26.80 10.030 4.003 78715.4 26.80 20.030 4.003 79915.4 26.80 25.030 4.003 79317.0 38.20 25.020 4.003 69417.0 38.20 50.020 4.003 78917.0 38.20 70.010 4.003 7849.0 15.80 2.050 4.003 79110.0 20.50 5.020 4.003 78615.4 26.80 10.020 4.003 78817.0 38.20 50.010 4.003 79015.4 26.80 10.01 4.003 73115.4 26.80 20.01 4.003 730Silica adsorbents for low pressure column chromatographystandard silica 60, pore size ~ 60 Å; pore volume ~ 0.75ml/g; spec. surface BET ~500m²/g. MACHEREY-NAGELhighly porous, amorphous silicic acid in the form of hard, opalescent particles, prepared byprecipitation of water glass with sulphuric acid. For higher demands on the performance of column packingswe recommend our high-purity irregular Polygoprep silicas. Silica FIA for the fluorescence indicator adsorptionprocedure for the determination of hydrocarbon groups in the testing of liquid fuels in accordance withDIN 51791 and ASTM D 1319-58T. The FIA method determines saturated hydrocarbons, olefins andaromatic hydrocarbons of a sample chromatographically by adsorption and desorption in a column filled withFIA silica, in the presence of a fluorescent dye mixture.Description Particle size Weight PK Cat. No.Silica 60, 0.015 - 0.04 mmSilica 60, 0.025 - 0.04 mmSilica 60, 0.04 - 0.063 mmSilica 60 M, 0.04 - 0.063 mmSilica 60, 0.05 - 0.1 mmSilica 60, 0.05 - 0.2 mmSilica 60, 0. 063 - 0.2 mmSilica 60, < 0.063 mmSilica 60, < 0.08 mmSilica 60, 0.1 - 0.2 mmSilica 60, 0.2 - 0.5 mmSilica 60, 0.5 - 1.0 mmSilica 60, 0.015 - 0.04 mmSilica 60, 0.025 - 0.04 mmSilica 60, 0.04 - 0.063 mmSilica 60 M, 0.04 - 0.063 mmSilica 60, 0.05 - 0.1 mmSilica 60, 0.05 - 0.2 mmSilica 60, 0. 063 - 0.2 mmSilica 60, < 0.063 mmSilica 60, < 0.08 mmSilica 60, 0.1 - 0.2 mmSilica 60, 0.2 - 0.5 mmSilica 60, 0.5 - 1.0 mmSilica 60, 0.015 - 0.04 mmSilica 60, 0.025 - 0.04 mmSilica 60, 0.04 - 0.063 mmSilica 60 M, 0.04 - 0.063 mmSilica 60, 0.05 - 0.1 mmSilica 60, 0.05 - 0.2 mmSilica 60, 0. 063 - 0.2 mmSilica 60, < 0.063 mmSilica 60, < 0.08 mmSilica 60, 0.2 - 0.5 mmSilica 60, 0.5 - 1.0 mmSilicia FIA fineSilicia FIA coarse230 - 400 mesh230 - 400 mesh130 -270 mesh70 -270 mesh70 - 230 mesh+ 230 mesh+ 190 mesh70 - 130 mesh35 - 70 mesh18 - 35 mesh230 - 400 mesh230 - 400 mesh130 - 270 mesh70 - 270 mesh70 - 230 mesh+ 230 mesh+ 190 mesh70 - 130 mesh35 - 70 mesh18 - 35 mesh230 - 400 mesh230 - 400 mesh130 - 270 mesh70 - 270 mesh70 - 230 mesh+ 230 mesh+ 190 mesh35 - 70 mesh18 - 35 mesh0,071 - 0,16 mesh0,071 - 0,63 meshkg11111111111155555555555525252525252525252525251111111111111111111111111111111111111114.004 9994.004 9484.004 9684.004 9714.004 9744.004 9544.004 9574.004 9774.004 9514.004 9604.004 9624.004 9654.005 0014.004 9504.004 9704.004 9734.004 9764.004 9564.004 9594.004 9794.004 9534.004 9614.004 9644.004 9674.005 0004.004 9494.004 9694.004 9724.004 9754.004 9554.004 9584.004 9784.004 9524.004 9634.004 9664.004 9804.004 98180E & OE.
LLG CHROMATOGRAPHY CATALOGUE<strong>Chromatography</strong><strong>Chromatography</strong> columns/Flash columnsFlorisil ® adsorbent for column chromatographyhard granular magnesia silica gel: MgO 15.5±0.5%, SiO2 84.0 ±0.5%, Na2SO4 ≤1.0%;MACHEREY-NAGEL60/100 meshtypical applications: sample preparation (SPE); clean-up of pesticide residues, separation of chlorinated pesticides,extraction of steroids, sex hormones, antibiotics, lipids etc.Description Particle size Weight PK Cat. No.Florisil standard 60 / 100 meshFlorisil standard 60 / 100 mesh0.15 / 0.25 mm0.15 / 0.25 mmkg15MN ready-to-use layers for TLCAdvantagescontinuous high qualityguaranteed by stringent production control includingstandardised lot tests, surface checks for roughnessor cracks as well as hardness and adherence checkscomprehensive range of phases for TLC / HPTLCthere is no universal TLC plate which meets all possibletypes of analyses. Our versatile range of TLCready-to-use layers covers many different types ofapplications.immediately ready for chromatographic separationcoatings or impregnations are not necessaryhomogeneous, smooth, well adhering layersan important criterium especially for reproduciblequantitative evaluation116.232 8734.005 002Electron microscopic photograph of a cross sectionthrough a glass plate with silica layer (magnification x500)1 2Chromatographic columns with Frit, PTFE- /or Valve Stopcock1 2LengthInt. Capacity Description PK Cat. No.diam.mm mm ml2004006002002001020301015151254301535without frit NS 14/23without frit NS 29/32without frit NS 29/32with frit (P=0) NS 14/23with frit (P=0) NS 14/23111114.008 3984.008 3994.008 4004.008 4014.008 4033 4 5Chromatographic columns, PTFE- or Valve Stopcock3 4DURAN ® tubing.<strong>Chromatography</strong> columns with sintered frit, porosity 0.Available in three versions:- with beaded rim and PTFE stopcock- with NS socket and PTFE stopcock- with NS socket and valve stopcock (bore 0 - 2.5mm)LenzLengthInt. Capacity Description Stopcock PK Cat. No.diam.mm mm ml2004006008001002003002004006002001520304010101015203015351254301000815233512543035beaded rimbeaded rimbeaded rimbeaded rimsocket NS 14/23socket NS 14/23socket NS 14/23socket NS 14/23socket NS 29/32socket NS 29/32socket NS 29/32PTFEPTFEPTFEPTFEPTFEPTFEPTFEPTFEPTFEPTFEValve111111111116.205 0176.202 4166.202 4176.202 4186.225 8599.025 9129.025 9139.025 9146.203 9616.303 2976.223 5745E & OE.81
- Page 2 and 3:
perfectly together!Product choice
- Page 4 and 5:
Alphabetical indexLLG CHROMATOGRAPH
- Page 6 and 7:
ChromatographyVials/Ampoules, Septa
- Page 8 and 9:
ChromatographyVials/Ampoules, Septa
- Page 10 and 11:
ChromatographyVials/Ampoules, Septa
- Page 12 and 13:
ChromatographyVials/Ampoules, Septa
- Page 14 and 15:
ChromatographyVials/Ampoules, Septa
- Page 16 and 17:
ChromatographyVials/Ampoules, Septa
- Page 18 and 19:
ChromatographyVials/Ampoules, Septa
- Page 20 and 21:
ChromatographyVials/Ampoules, Septa
- Page 22 and 23:
ChromatographyVials/Ampoules, Septa
- Page 24 and 25:
ChromatographyVials/Ampoules, Septa
- Page 26 and 27:
ChromatographyVials/Ampoules, Septa
- Page 28 and 29:
ChromatographyVials/Ampoules, Septa
- Page 30 and 31:
ChromatographyVials/Ampoules, Septa
- Page 32 and 33: ChromatographyVials/Ampoules, Septa
- Page 34 and 35: perfectly together!Product choice
- Page 36 and 37: ChromatographySyringes/Microlitre S
- Page 38 and 39: ChromatographySyringes/Microlitre S
- Page 40 and 41: ChromatographySyringes/Microlitre S
- Page 42 and 43: Microliter SyringesFor Chromatogra
- Page 44 and 45: ChromatographySample preparation/SP
- Page 46 and 47: ChromatographySample preparation/SP
- Page 48 and 49: ChromatographySample preparation/SP
- Page 50 and 51: ChromatographySample preparation/SP
- Page 52 and 53: ChromatographySample preparation/SP
- Page 54 and 55: ChromatographySample preparation/Sy
- Page 56 and 57: ChromatographySample preparation/Sy
- Page 58 and 59: ChromatographyChromatography column
- Page 60 and 61: ChromatographyChromatography column
- Page 62 and 63: ChromatographyChromatography column
- Page 64 and 65: ChromatographyChromatography column
- Page 66 and 67: ChromatographyChromatography column
- Page 68 and 69: ChromatographyChromatography column
- Page 70 and 71: ChromatographyChromatography column
- Page 72 and 73: ChromatographyChromatography column
- Page 74 and 75: ChromatographyChromatography column
- Page 76 and 77: ChromatographyChromatography column
- Page 78 and 79: ChromatographyChromatography column
- Page 80 and 81: ChromatographyChromatography column
- Page 84 and 85: ChromatographyChromatography column
- Page 86 and 87: ChromatographyChromatography column
- Page 89 and 90: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 91 and 92: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 93 and 94: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 95 and 96: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 97 and 98: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 99 and 100: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 101 and 102: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 103 and 104: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 105 and 106: LLG CHROMATOGRAPHY CATALOGUEReady-t
- Page 107 and 108: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 109 and 110: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 111 and 112: LLG CHROMATOGRAPHY CATALOGUEChromat
- Page 113 and 114: Notes111