11.07.2015 Views

conduit systems for electrical wires and cables - drive-electric.hu

conduit systems for electrical wires and cables - drive-electric.hu

conduit systems for electrical wires and cables - drive-electric.hu

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ANACONDA stainless steel fittings, the UNIVERSAL solutionAnaconda stainless steel fittings: Universal & extra corrosion resistantFor the development of the Anaconda stainless steel fi ttings a solution was sought to match all types of <strong>conduit</strong> in our program.For this reason we have decided to develop a 4 piece fi tting. The construction is fully adapted to the Anaconda Sealtite<strong>conduit</strong> <strong>and</strong> guarantees an IP 67 watertight connection. In case of the cable hose fi tting even an IP 68 can be obtained. Therobust construction meets all the high UL / CSA dem<strong>and</strong>s. The usage of stainless steel guarantees a superior corrosionresistance. The Anaconda stainless steel fi ttings are available in a complete program; ISO metric Pg <strong>and</strong> NPT in straight, 45°<strong>and</strong> 90° male execution. In order to have a unifi ed usage of the Anaconda fi ttings small adjustments through connection setsare neccessary . Below an overview of the various <strong>conduit</strong>s <strong>and</strong> their solution.ANACONDA FITTINGS: stainless steel (AISI-303 <strong>and</strong> AISI-316)The counter nut <strong>and</strong> body are stainless steel (AISI-303 or AISI 316), other parts are listed below.Conduit Partnumber Method of delivery Material ApprovalsProtectionType Last digit clamping ring Ferrule ClassMultiflex SLI.9St<strong>and</strong>ard fi tting (.9)Connection set must beordered additionally.Nickel platedbrassNickel platedbrassIP 40Multiflex SLB.9St<strong>and</strong>ard fi tting (.9)Clamping ring must beordered additionally.GalvanisedsteelNickel platedbrassIP 40Multiflex UI.8St<strong>and</strong>ard fi tting (.9)including connection set(separately packed).Nickel platedbrassNickel platedbrassIP 40STAINLESSSTEELFITTINGINFORMATIONMultitite FCD-EF / -PUSEALTITE all (except CNP).9.9St<strong>and</strong>ard fi tting (.9)Connection set must beordered additionally.St<strong>and</strong>ard fi tting (.9)NBR rubberPA6Nickel platedbrassNickel platedbrassIP 68 *IP 67 *SEALTITE NMUA.9St<strong>and</strong>ard fi tting (.9)PA6Nickel platedbrassIP 67 *Hiprojacket.9St<strong>and</strong>ard fi tting (.9)Clamping ring must beordered additionally.Zinc platedbrassNickel platedbrassIP 54Thermojacket “S”.9St<strong>and</strong>ard fi tting (.9)Clamping ring must beordered additionally.Nickel platedbrassNickel platedbrassIP 40Note:All Anaconda fi ttings are IP 67 on the Sealtite <strong>conduit</strong>. They are also IP 67 on the switchbox, with exception of the cable-hosefittings (IP 68).Special remark:Above outlined is not applicable <strong>for</strong> ATEX fi ttings. In case of ATEX fi ttings the connection always must be ordered additionally.11-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!