Unit Operation Instruction<strong>KilnLoq</strong> <strong>probe</strong> & EXDthe cooling jacket. The hot water returns by the centre “chamber” <strong>and</strong> exits the wateroutlet.6.3.3 HEATED SAMPLE PIPEThe purpose with the heated pipe is to transport the sample gas from the cement process tothe filter house. The heated sample pipe consists of a stainless inner pipe, heating cable,insulation material <strong>and</strong> an outer pipe assembled with two flanges. The power supply for theheating cables enters between the two flanges. To avoid mechanical tensions the inner pipeis “fixed” in only one end. To avoid condensation, the temperature of the gas path throughthe heated pipe is controlled by the <strong>Gas</strong> Monitoring Unit. The temperature set point isadjusted on the temperature controller for heated sample pipe. The controller is located inthe <strong>Gas</strong> Monitoring Unit <strong>and</strong> the default temperature setting is found in data sheets.6.3.4 FILTER HOUSEThe purpose with the filter house is to clean the sample gas from dust before it enters theheated sample hose to the <strong>Gas</strong> Monitoring Unit. The filter house consists of a stainlesshouse, lid <strong>and</strong> filter. The house is bolted directly to the heated sample pipe <strong>and</strong> sealed withan O-ring. The house is heated with four heating elements <strong>and</strong> it contains connectors forblow back air <strong>and</strong> sample hose. The stainless sintered filter is fixed only in the removablelid. This gives easy maintenance <strong>and</strong> allows the filter to extend when the house is heated.To avoid condensation, the temperature of the filter house is controlled by the <strong>Gas</strong>Monitoring Unit. The temperature set point is adjusted on the temperature controller forfilter house. The controller is located in the <strong>Gas</strong> Monitoring Unit <strong>and</strong> the default temperaturesetting is found in data sheets.6.3.5 FUNCTIONIn normal operation the gas flows through the heated pipe to the filter house, through thefilter <strong>and</strong> out to the heated sample hose. The dust is then collected at the inside of thesintered filter. After a pre-adjusted duration the sample stops <strong>and</strong> the filter is cleaned bycompressed air connected to the filter house <strong>and</strong> lid. To avoid condensation, thetemperature of the entire gas path through the <strong>KilnLoq</strong> <strong>probe</strong> is controlled by the <strong>Gas</strong>Monitoring Unit.6.3.6 COOLING JACKET TIP CLEANING SYSTEMIn order to keep the cooling jacket tip clean from build up the system can be equipped witha cooling jacket cleaner.The cooling jacket cleaner consists of valve that controls airflow. Cooling jacket cleaning isperformed during <strong>probe</strong> cleaning sequence. Air is lead between the inner of cooling jacket<strong>and</strong> Heated pipe approximately 1-8 seconds during first part of cleaning sequence.Page 12 of 27

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!