KilnLoq probe and Extraction device - Webshop, Gas Analysis ...
KilnLoq probe and Extraction device - Webshop, Gas Analysis ...
KilnLoq probe and Extraction device - Webshop, Gas Analysis ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Unit Operation Instruction<strong>KilnLoq</strong> <strong>probe</strong> & EXD2 PREFACEThis operating instruction is called a unit manual. The operating instruction covers only thisparticnular unit with respect to technical data, installation, use etc. This specific unit is apart of a complete system. Control <strong>and</strong> interaction in the specific system may varyaccording to system dem<strong>and</strong>s.The <strong>KilnLoq</strong> Probe is to be used with FLSmidth analysis system. The Probe comprises aProbe, piping, Filter, connections among others.Further more this instruction covers the <strong>Extraction</strong> <strong>device</strong> version 2 (EXD2) that is dedicatedto support <strong>and</strong> protect the <strong>KilnLoq</strong> <strong>probe</strong>.The system interaction with the <strong>KilnLoq</strong>-Probe is described in the system manual. Thedocument overview is to be found in section 2.1.The whole analysis system is to be operated <strong>and</strong> maintained as described in the systemmanual. If not, the efficiency <strong>and</strong> lifetime of the system will be reduced. An alarm mustalways be corrected at once. Qualified <strong>and</strong> trained personnel must perform themaintenance.2.1 DOCUMENT MAPThis manual is to be considered as part of the complete system documentation. A completeset of system documentation for an FLSmidth gas analysis system may comprise:User manuals (Binder) (all project specific drawings, list etc.) includingSystem data sheet covers project specific data.System operation instructionsUnit operating instructions (this document among others)Drawings, lists etc.Data sheets (Binder)Sub supplier’s manuals <strong>and</strong> datasheets2.2 DEFINITIONS AND TERMS2.2.1 GENERALSystem (analysis system)The complete analysis system which includes this unit amongothersSystem manualThe manual covering system function <strong>and</strong> interaction with this unitSystem datasheetOverall system data where all technical data <strong>and</strong> units are identifiedUnit manualAn operating instruction for a specific unit (Part of complete system. E.g. for aProbe)GMU <strong>Gas</strong> Monitoring Unit: Cabinet or housing comprising analysis parts, power distribution<strong>and</strong> control.CUBE FLSmidth analysis housing insulated, heated, cooled <strong>and</strong> with GMU installed.Trained/qualified PersonnelIndicates personnel that is not only certified to work on the plantaccording to all local <strong>and</strong> national regulations, but personnel who also has specific trainingfrom FLSmidth in use <strong>and</strong> maintenance of gas analysis systems.2.2.2 UNITS AND CONVERSION FACTORSAll units in FLSmidth <strong>Gas</strong> <strong>Analysis</strong> Technology documentation are SI-units except from:Pressure:BarTemperature:°C (degrees Celsius)Page 4 of 27