(3) Loosely install the union nut (2) that attaches the breather tube(79-11-01, 03-170) to the oil tank emergency fill adapter (79-11-01,03-180).(4) Loosely install the union nut (1) that attaches the breather tube(79-11-01, 03-170) to the ROFV (79-11-01, 03-100).(5) Torque the two union nuts (1) and (2) of the breather tube (79-11-01,03-170) to 19 Nm (170 lbf in.).(6) Safety the two union nuts (1) and (2) of the breather tube (79-11-01,03-170) with safety cable (OMat 2/142) or with lockwire (OMat 238).NOTE:Safety cable (OMat 2/142) is the preferred locking material.Printed in Great BritainI. Replenish the oil tank with engine oil (Refer to the Aircraft MaintenanceManual, Chapter 12-14-79, PB301).J. Make sure that the remote oil fill system on aircraft side is activated.K. Make sure that the work area is clean and clear of tools, equipment and otherunwanted materials.L. Do an engine run leak check (Test 2) (Refer to the Aircraft Maintenance Manual,Chapter 71-00-00, PB501).M. Close the access to the ROFV(1) Close the cowl doors (Refer to the Aircraft Maintenance Manual, Chapter71-10-00, PB201).N. A record of accomplishment is required. <strong>Rolls</strong>-<strong>Royce</strong> Deutschland suggests to putan entry into the engine log book.Jul.14/06Jul.14/06TAY−79−1698Page 10