<strong>Protec</strong><strong>Protec</strong> Fire Detection plcFire Detection - Addressable<strong>Protec</strong> <strong>Algo</strong>-Tec TM <strong>6100</strong>Interactive Digital Addressable Fire Control SystemA D D R E S S I N G S A F E T Y S Y S T E M S W I T H I N T E L L I G E N C E


Fire Detection - Addressable<strong>Protec</strong><strong>Protec</strong> Fire Detection plc<strong>Protec</strong> <strong>Algo</strong>-Tec TM <strong>6100</strong>INTERACTIVE DIGITAL ADDRESSABLEFIRE CONTROL SYSTEM• Cost Effective Single Loop Panel• High Capacity Loop - 192 Addresses• <strong>Algo</strong>-Tec TM 6000PLUS Protocol• Surface and Recessed Mounting• Easy to Install• Reduced False Alarms• Enhanced Performance• On Site Flexibility• Designed to EN 54-2 & 4• Open ProtocolSystem FeaturesThe <strong>Protec</strong> <strong>Algo</strong>-Tec TM <strong>6100</strong> is an interactive digitaladdressable fire detection and alarm system ideally suitedfor small and medium sized buildings such as shops,hotels and offices. The control panel is designed andmanufactured by <strong>Protec</strong> to comply with EN 54-2 & 4. Thecontrol panel is suitable for surface or recessed mountingwith a moulded polycarbonate enclosure finished in stormgrey.LoopThe <strong>6100</strong> control panel is equipped with a high capacity<strong>Algo</strong>-Tec TM digital addressable data loop, with up to 192addresses. In addition to the <strong>Algo</strong>-Tec TM 6000PLUSsensors, interfaces and manual call points the loop canalso support loop powered SOUNDERS, BEACONS andOPTICAL BEAM DETECTORS. Additionally a 6300 LoopPowered Repeat Display can be connected directly to thisloop, resulting in reduced cabling requirements, simplifiedinstallation and associated cost savings.AlarmsIn addition to loop powered sounders and beacons, 2 fullymonitored alarm outputs are provided at the panel foralternative wiring arrangements.Auxiliary ContactsOne set of global fire, and one set of fault changeovercontacts.Controls and DisplayAll the functions of the modern styled Control Panel areaccessed by entering the user access code. The controlsare SILENCE, SOUND ALARMS, RESET and ACCEPT plusnavigation push buttons to enable access to the usermenu facilities. The control panel display consists of a4x20 character liquid crystal display, twin common fireLED indicators, 16 separate zonal fire LED’s, power on,pre-alarm, system fault, common fault, test anddisablement LEDs.Liquid Crystal DisplayThe 80 character liquid crystal display will under normal quiescent conditions displaythe current date and time with the option to also display a 40-character user’smessage such as site name.In an alarm or fault condition the LCD will display the device, address and zonenumber and up to 20 characters of user definable location text, programmable on siteusing <strong>Protec</strong> <strong>6100</strong> windows based software.Device Location TextWindows based text software is supplied free of charge to our clients to enable youto enter the location text on to the disk supplied and hand to our commissioningengineer for loading into the panel during commissioning. This simple process allowsyou more flexibility enabling you to make any last minute changes and speed up theentire process.Power SupplyThe <strong>6100</strong> control panel is supplied with an integral 1A dc switch mode charger andaccommodates two 12V 3.3 Ah sealed lead acid battery.On Site ProgrammingThe <strong>Protec</strong> <strong>Algo</strong>-Tec <strong>6100</strong> system is on site programmable. All of thecommissioning configuration data can be entered and/or backed up using the <strong>Protec</strong><strong>6100</strong> windows based programming software via a PC. This feature enables thesystem to be re-configured and checked prior to attending site simplifyingcommissioning works on site, enabling text amendments to be carried out whilst onsite and providing an invaluable remote backup should the need arise.


Loop DevicesThe <strong>Protec</strong> <strong>Algo</strong>-Tec 6000PLUS protocol utilises FAST addressing (Firmware Addressed Secure Technology).Every FAST device is manufactured with a unique serialnumber.FAST addressing ELIMINATES troublesome and timeconsuming address cards and DIL switching whilst beingfar more secure than “soft addressing”.The <strong>Protec</strong> <strong>Algo</strong>-Tec 6000PLUS sensor range has beendeveloped to incorporate advanced fire sensingtechnology, electronic sounders, high intensity LEDwarning beacons and speech enhanced talking soundercapability, all integrated within the sensor head andpowered from the loop.Plant shutdowninterface 6000/MICCOHeavy duty plant shutdownsignal (Rated at 240V 5A)EOLEOL6300 Loop repeaterLOOP 1EOLEOLSprinkler delayinterface6000/MICCOPlant shutdownoutput (Ratedat 240V 5A)Typical Sensor Variants6000PLUS/OPHT/S = c/w Sounder6000PLUS/OPHT/L = c/w LED Beacon6000PLUS/OPHT/SL = c/w Sounder and LED Beacon6000PLUS/OPHT/TS = c/w Talking Sounder6000PLUS/OPHT/TSL = c/wTalkingSounderandLEDBeaconAlarm circuitAlarm circuitZone circuitZone circuit6000PLUS/HT FAST TM Interactive Heat Sensor - Interactiveaddressable heat sensor with low thermal massthermistor, giving fast response to temperatureincreases. Other Heat Sensor variants include:6000PLUS/HT/S, 6000PLUS/HT/SL6000PLUS/HT/TSL6000/LPZALoop poweredzone alarminterface6000/ZAIZone alarminterface6000PLUS/OP FAST TM Interactive Optical Smoke Sensor -Interactive addressable high performance opticalsmoke sensor provide efficient reliable detectionusing the light scatter sensing principle with rapidresponse to a fire signal. Other Optical Sensorvariants include: 6000PLUS/OP/SSingle 2 wire loop cableBCI/2.8230V24V supply (4C)Power supply unit6000PLUS/OPHT FAST TM Interactive Optical Heat Sensor -Interactive addressable high performance opticalsmoke and heat multi-sensor. Other Optical HeatSensor variants include:6000PLUS/OPHT/S, 6000PLUS/OPHT/L,6000PLUS/OPHT/SL, 6000PLUS/OPHT/TS,6000PLUS/OPHT/TSL6000PLUS/OPHTCO FAST TM Interactive Optical Heat CO Sensor -Interactive addressable high performance opticalsmoke heat and carbon monoxide multi-sensor.Other Optical Heat CO Sensor variants include:6000PLUS/OPHTCO/S, 6000PLUS/OPHTCO/L,6000PLUS/OPHTCO/SL, 6000PLUS/OPHTCO/TSL6000PLUS/BASELow Profile Common Mounting Base - Compatiblewith the above range of <strong>Algo</strong>-Tec TM 6000PLUSSensors.} 2 monitored alarm outputsMonitored fire station output1 Auxiliary fire c/o contact1 Auxiliary fault c/o contacts24V Aux. outputBomb alert/class change inputRemote alarm inputMains ac supply6000PLUS/FFBASE Fast Fixed Base - Fast fixed recessed base isdesigned to recess the sensor into a false ceilingto give a lower profile view of the sensor.KEY:Heat SensorZone Alarm Interface6300/LOOP/LCD Repeater - Connected directly to the local data loopand takes up just one address. The 1 x 40character LCD Display provides clear text locationof fire and fault events.Optical Smoke and Heat SensorOptical Smoke, Heat and CO SensorDuct Probe Unit c/w Smoke SensorMonitored Input CC Output InterfaceElectronic SounderFlashing Beacon6000/MCPFAST TM Addressable Manual Call Point - Keyoperated test facility, a loop short circuit isolator isincorporated.Manual Call PointBeam DetectorTalking Sounder with LED Beacon6300 Loop LCD DisplayLoop Powered Zone Alarm Interface


TotalLoopLoadinAlarm(mA)Guide to loop cable conductor sizing for the <strong>Protec</strong> <strong>6100</strong> system.Loop Length (Metres)500 550 600 650 700 750 800 850 900 950 1000501001502002503003504004505005506006000PLUS/UG4DP Ventilation Duct Smoke Sensor Assembly - Singlepipe air sampling unit for air speeds from 0.5 to20m per sec. supplied with 6000PLUS/BASEsuitable for use with 6000PLUS/OP FAST TMinteractive optical smoke sensor.6000/FIREBEAM FAST TM Addressable Loop Powered BeamDetector - Combined transmitter/receiver unit andseparate low level controller. With a beam rangeof 5-100 metres.6000/LEDFAST TM Addressable Loop Powered High IntensityFlashing Beacon - The 6000/LED has 18 highintensity LEDs, and due to the low current design,is addressable and loop powered, utilising the<strong>Protec</strong> <strong>Algo</strong>-Tec TM 6000 Protocol.Fire Detection - AddressableTotalLoopLoadinAlarm(mA)50100150200250300350400450500550600Loop Length (Metres)1000 1050 1100 1150 1200 1250 1300 1350 1400 1450 1500TThe conductor size required as follows1.0mm 2 Conductor required1.5mm 2 Conductor required2.5mm 2 Conductor requiredMAXIMUM LOOP RESISTANCE 16 OHMS PER CONDUCTORProductTable detailing the loop standby and alarm load for typical<strong>Algo</strong>-tec 6000PLUS devices.DescriptionNumber ofAddressesn/aLoopStandbyLoad mAn/an/an/an/aLoop AlarmLoad mA6000/MCP Manual Call Point 1 0.5 3.46000/SSR6000/SSR/LED6000/FIUFAST TM Addressable Loop Powered High OutputElectronic Sounder - utilises a Piezo driver unit toenable high sound output and very low currentconsumption.FAST TM Addressable Loop Powered High OutputElectronic Sounder with LED Beacon - a lowcurrent loop powered addressable device. Withtypical sound output of 100dB(A) at 1m, the toneand volume options are selectable by the controlpanel.6000PLUS/TSR2 FAST TM Addressable Loop Powered TalkingSounder - The 6000PLUS/TSR2 voice enhancedtalking sounder is available with seven voicemessages plus ‘bell’ sound in addition to the threefire alarm tones compatible with the <strong>Protec</strong> rangeof electronic sounders.6000PLUS/TSR2/LED FAST TM Addressable Loop Powered TalkingSounder with LED Beacon - the <strong>Protec</strong> <strong>Algo</strong>-Tec6000PLUS/TSR2/LED is equipped with anintegrated voice enhanced sounder and highintensity flashing beacon array.Flush Mounted Short Circuit Isolator Unit - Toisolate a short circuit fault on either the incomingor outgoing loop cables. Suitable for a 30mm deepelectrical mounting box.6000/FIREBEAM Loop Beam 1 3.65 76000PLUS/HT Heat Sensor 1 0.2 0.26000PLUS/HT/S Heat Sensor c/w Sounder 1 0.4 5.46000PLUS/OPHT Optical Smoke and Heat Sensor 1 0.2 0.26000PLUS/OPHT/S6000PLUS/OPHT/SL6000PLUS/OPHT/TSLOptical Smoke and Heat Sensor c/wSounderOptical Smoke and Heat Sensor c/wSounder and BeaconOptical Smoke and Heat Sensor c/wTalking Sounder and Beacon1 0.4 5.41 0.4 10.41 0.4 13.46000PLUS/OPHTCO Optical Smoke, Heat, and CO Sensor 1 0.45 0.456000PLUS/OPHTCO/SOptical Smoke, Heat, and CO Sensorc/w Sounder1 0.45 5.456000/LED Loop Beacon 1 0.5 5.56000/SSR Loop Sounder 1 0.7 5.76000/SSR/LED Loop Sounder Beacon 1 0.7 10.76000/ZAI* Zone Alarm Interface 1 2 46000/MICCO Monitored Input CC Output 1 0.55 5Note: The following Loop Parameters should be observed1) The total number of addressable devices should not exceed 192 per loop.2) Add 20mA to total loop alarm load to allow for fire indicator LED’s on devices3) The total loop alarm load should not exceed 600mA per loop.* Auxiliary 24V dc supply required.6000/LPZA FAST TM Addressable Flush Mounted LoopPowered Zone Alarm Interface Unit - With amonitored detection circuit suitable for use with<strong>Protec</strong> 3000 series detection devices. Linecontinuity maintained. Monitored alarm outputcircuit rated at 24V dc 50mA max. Suitable for a45mm deep electrical mounting box. A loop short circuit isolator isincluded.6000/ZAI FAST TM Addressable Flush Mounted Zone AlarmInterface Unit - With a monitored detection circuitsuitable for use with <strong>Protec</strong> 3000 series detectiondevices. Line continuity maintained. Monitoredalarm output circuit rated at 24V dc 1A max.Suitable for a 45mm deep electrical mounting box.A loop short circuit isolator is included.6000/MICCO FAST TM Addressable Flush Mounted LoopPowered Monitored Input, Clean Contact OutputInterface Unit - With a monitored input circuitsuitable for use with simple switch devices and theoutput is a clean changeover contact 5A rated at240V ac. A link can be cut to provide a 7-seconddelay to the input. Suitable for a 45mm deep electrical mounting box.A loop short circuit isolator is incorporated.Multi-way Input/Output Interfaces - A range of 16 way input/outputinterfaces are available with monitored alarmoutputs or clean changeover contacts. Allinterfaces are FAST TM addressable.


CAUTION<strong>Algo</strong>-Tec 6000PLUS Interactive Decision Making <strong>Algo</strong>rithms - Typical ApplicationsOffice Mode (High Performance)ALARMComputer FireDay/Night ModeOfficesDISCRIMINATINGALGORITHMCigarette SmokeALARMBin FireFactory Loading BayClean Mode (Extra High Performance)ALARMPrinter Paper FireBedroom ModeALARMComputer Room FireALARMChemical FireDISCRIMINATINGALGORITHMSteam From BathroomThe <strong>Protec</strong> <strong>Algo</strong>-Tec <strong>6100</strong> Interactive DigitalAddressable System unwrapped:The <strong>Protec</strong> <strong>Algo</strong>-Tec TM 6000PLUS protocol developed by<strong>Protec</strong>’s in-house Research and Development team isutilised by the <strong>Protec</strong> <strong>Algo</strong>-Tec TM <strong>6100</strong> interactive digitaladdressable fire control systems. Immunity to falsealarms, more responsive fire detection, and ease of usehas all been achieved to develop one of the most reliablesystems available.<strong>Protec</strong> <strong>Algo</strong>-Tec 6000PLUSThe name <strong>Algo</strong>-Tec TM is a derivative of <strong>Protec</strong> algorithms.<strong>Algo</strong>rithms are logical mathematical procedures forsolving problems. <strong>Protec</strong> have developed fire detectionalgorithms coupled with fuzzy logic specifically designedto reduce unwanted fire alarms and to enhance thesensitivity of the system to true fire phenomenon. The<strong>Algo</strong>-Tec TM algorithms are exclusively utilised by the<strong>Protec</strong> <strong>Algo</strong>-Tec TM 6400, 6300 and <strong>6100</strong> Interactive DigitalAddressable Fire Control Systems.Fire Detection - AddressableDay Mode:Office mode (high performance)OfficesNight Mode:Clean mode (Extra high performance)Day Mode:Heat detection only (6000PLUS/OPHT)Factory Loading BayNight Mode:Smoke & Heat detectionDISCRIMINATINGALGORITHMAerosols in BedroomSmoldering FireALARMNOTE: The above examples give an indication of system reaction to intermittent contaminants andtypical fire sources in a correctly designed BS5839 system . They by no means detail the full complexityof the systems decision making algorithms. Examples are for 6000PLUS/OPHT.Interactive<strong>Algo</strong>-Tec TM evaluates the data of each fire sensor and isable to learn from the information received. This maysimply be to recognise that a sensor is becomingcontaminated or in a dirty environment and toautomatically increase the alarm threshold tocompensate for the background levels (ThresholdCompensation).More complex <strong>Algo</strong>-Tec TM functions include the ability todiscriminate between certain fire and non-fire conditions,filtering out certain environmental stimuli, and increasingthe sensitivity of a sensor when an increase intemperature is detected.The net effect of the interaction between the sensors andthe <strong>Algo</strong>-Tec TM decision making is enhancedperformance, through immunity to false alarms and moreresponsive fire detection.6300 Loop LCD DisplayThe 6300/LOOP/LCD can be connected directly to the local <strong>Algo</strong>-Tec TM digital addressabledata loop and takes up just one address. The facia displays power, fire, fault, disablementand more alarms.Fire and fault events are displayed on the 2 x 40 character LCD display and automaticallyscroll. A backlight ensures that the events can be read in all lighting situations. Fireevents have highest priority and inhibit the display of fault events. A new event initiatesthe internal buzzer and a mute button allows the internal buzzer to be muted.Loop standby/Alarm load 60mA.Dimensions (mm): 360(W) x 215(H) x 47(D)Digital AddressableThe data communication between the sensors and thecontrol equipment is Digital.The <strong>Algo</strong>-Tec TM protocol utilised by the 6000PLUS systemenables high levels of data to be transferred, providingfar more detailed information than was previouslyachievable with analogue addressable systems. It shouldhowever be noted that many analogue addressablesystems use digital communication but do not transfer thehigh levels of data associated with the <strong>Algo</strong>-Tec TMprotocol. Speed, stability, excellent EMC and security allserve to enhance the <strong>Algo</strong>-Tec TM Digital signalling. Whygo analogue addressable when you can now choose<strong>Algo</strong>-Tec TM Digital Addressable.


Fire Detection - AddressableTechnical Specification<strong>6100</strong> Control Panel Complies with EN54-2 & 4Model:-Specification:-Power SupplyWorking VoltageTemperature RangeMaximum HumidityStandby Load (Mains Fail Condition)Alarm Load (Mains Fail Condition)<strong>6100</strong> - Single Loop.Mains 85 - 264V ac (50-60Hz).21.5 - 30V dc.0 - 40°C.85% Non-condensing.22mA.56mA (plus 7mA if fire link module used).DisplayBacklit liquid crystal display 4 lines of 20 characters.Digital Addressable Loops1 loop, with 192 address capacity. <strong>Algo</strong>-Tec 6000PLUS Protocol.Total Loop Load600mA including all loop connected devices.Zones31 Zones, 16 with LED indication, plus general fire indicator.Integral Charger1A dc switch mode, temperature compensated.Integral Battery2 x 12V 3.3Ah Sealed Lead Acid.Programmable Alarm Outputs2 monitored conventional sounder circuits (100mA per output maximum).1 set of non-monitored changeover contacts (1A @ 24V dc)Up to 192 alarm outputs with additional loop output devices.Alarm Load600mA loop, 100mA per conventional alarm output.Fault Monitoring Fully fault monitored to EN 54-2 & 4.Fault OutputSingle pole changeover contacts (1A rated @ 24V dc).Auxiliary Output Supply24V dc fused at 150mA.Common Fire Output (fire station)24V dc fully monitored output (requires end of line module SF4165759).Communications InterfaceUSB (Type A male to Type B male connection lead required).Dimensions (mm)228(W) x 345(H) x 111(D).Weight1.5kg (excluding batteries).Applicable Standards EN 54-2 : 1997 + A1 : 2006.EN 54-4 : 1998 + A1 + A2.EN 54-13:2005.Programmability32 Input Groups First 31 groups are available for detection zones, group 32 is reserved for Sound Alarms push button.32 Output Groups Each output group can have a delay programmed (5 seconds to 10 minutes).Each output group can be set as Alarm or Control output.Non-LatchingUp to 32 loop addresses may be programmed to be non-latching.CoincidenceTo EN 54-2 Type C dependency.Detection SensitivitiesEach detector may have one of two sensitivities programmed.Sounder VolumeEach loop sounder may be programmed to be low, medium or high volume.Day/Night TimeThe panel may be programmed into two time zones to run different sensitivities for each detector.Sounder Pulsing TimeThe sounder on and off times may be programmed from 0.5 sec to 128 sec in 0.5 second increments.Talking Sounder Synchronisation Time1 sec to 120 sec in 1 second increments.Fire Link Delay Time5 seconds to 10 minutes in 5 second increments.Walk Test Time1 sec to 255 sec in 1 second increments.Windows Software Suite Proprietary software suite designed specifically for the <strong>6100</strong>.Allows text editing, matrix configuration, setup of all panel parameters.TextPanel TextDevice Address TextZone TextLanguage Support2 lines of 20 character panel text. Displayed when the system is ‘normal’.20 characters of device address text.20 characters of zone text.The <strong>6100</strong> will support multiple languages.<strong>Protec</strong><strong>Protec</strong> Fire Detection plc<strong>Protec</strong>: ScotlandTel: 0845 456 5390Fax: 0845 456 5391<strong>Protec</strong>: North EastTel: 0845 456 5396Fax: 0845 456 5397<strong>Protec</strong>: YorkshireTel: 0845 456 5388Fax: 0845 456 5389<strong>Protec</strong>: MidlandsTel: 0845 456 5398Fax: 0845 456 5399<strong>Protec</strong>: South EastTel: 0845 456 5394Fax: 0845 456 5395<strong>Protec</strong>: South WestTel: 0845 456 5392Fax: 0845 456 5393Company Policy is one of continuous improvement, we reserve the right to change specification without prior notice<strong>Protec</strong> Fire Detection Plc, <strong>Protec</strong> House, Churchill Way, Nelson, Lancashire, BB9 6RTTel: 01282 717171 Fax: 01282 717273 Web: www.protec.co.uk Email: sales@protec.co.ukMED1573 Issue 1 N 92-168-76