11.07.2015 Views

6000/SSR Electronic Sounder - Protec Fire Detection

6000/SSR Electronic Sounder - Protec Fire Detection

6000/SSR Electronic Sounder - Protec Fire Detection

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

• <strong>Protec</strong> AlgoTec <strong>6000</strong> Protocol• Loop Powered<strong>6000</strong>/<strong>SSR</strong> <strong>Electronic</strong> <strong>Sounder</strong><strong>Fire</strong> <strong>Detection</strong> - Addressable• High Output <strong>Electronic</strong> <strong>Sounder</strong>• Low Current Consumption• Integral Short Circuit Isolator• Weatherproof to IP65• Choice of ColoursThe <strong>6000</strong>/<strong>SSR</strong> addressable loop poweredhigh output electronic sounder designedby <strong>Protec</strong> in house developers, utilises aPiezo driver unit to enable high soundoutput and very low current consumption.With two base options and improvedaesthetic appearance the <strong>6000</strong>/<strong>SSR</strong>simplifies the installation of the device.The <strong>6000</strong>/<strong>SSR</strong> is a low current looppowered addressable device utilising the<strong>Protec</strong> Algo-Tec <strong>6000</strong> protocol. Withtypical sound output of 100dB(A) at 1m thesounder has 3 different tones (warble,continuous and pulse) selectable at thecontrol panel. Volume can be adjustedbetween 100, 95 and 75 dB(A), again at thecontrol panel. The <strong>6000</strong>/<strong>SSR</strong> incorporatesa loop short circuit isolator to enhance thesystem integrity and is designed to complyto all relevant CE and LVD standards.Available in either Red or White bodycolours, the <strong>6000</strong>/<strong>SSR</strong> has an IP65 ratingmaking the product suitable for mountinginternally or externally. An optional deepbase allows surface mounted cable to beterminated directly into the sounder.The <strong>6000</strong>/<strong>SSR</strong> is an ideal addition to anyfire alarm system providing a clear audibleindication of a fire alarm.As <strong>Protec</strong> are specialists in the safetysystems market, our main objective is toproduce high quality and reliableproducts. Manufacturing at our UK basedfacilities, our in-house design teamdevelop innovative products which areproduced using the latest manufacturingtechniques with in-line automatic testequipment to ensure consistent highquality and reliability.<strong>6000</strong>/<strong>SSR</strong><strong>6000</strong>/<strong>SSR</strong> + 28-982-75<strong>6000</strong>/SSW<strong>6000</strong>/SSW + 28-983-76A D D R E S S I N G S A F E T Y S Y S T E M S W I T H I N T E L L I G E N C E


<strong>Fire</strong> <strong>Detection</strong> - AddressableDimensions (mm)54.2mm<strong>6000</strong>/<strong>SSR</strong> Technical Specification11.2mm114.4mmLoop WiringPCB Connection Details Rear View (Gland Box Removed)RVAV LEDLOOP+LOOP-REMOVABLESERIAL No.LABELSTechnical Specification:Loop PoweredYesLoop Standby Load 700µALoop Alarm LoadNumber of Addresses 1Loop IsolatorOutput DetailsWeightTemperature RangeHumidityIP RatingConstruction5mAYesPiezo sounder. <strong>Sounder</strong> tone andvolume selectable at the controlpanel244g-10 o C to 55 o C0 to 85% RH non condensingIP65ABS Base & BodyApplicable Standards Designed to EN54 Part 3 & 17Compliant to CE and LVD standardsApprovalsDevice Protocol Algo-Tec <strong>6000</strong>LPCB to EN54 Part 3 : 2001 Cert No 201nFAST AddressingFAST (Firmware Addressed SecureTechnology). Each Algo-Tec <strong>6000</strong> deviceis manufactured with a unique serialnumber factory programmed (firmwareembedded) and device label. The labelincludes the serial number on 2 bar-codedsegments, 2 of which are removable by theinstaller (one is a spare). The label isattached to an address location booklet,which is handed to the engineer prior tocommissioning. During commissioning theengineer scans the address locationbooklet to download the loop, address andserial number details. The downloadeddata is then checked and stored within thesecure non-volatile memory of the controlpanel and the addressing is complete.FAST and easy, eliminating troublesomeand time consuming setting of addresscards and DIL switches. FAST addressingis more secure than ‘SOFT ADDRESSING’and easier to extend or amend, allowinggreater flexibility and reduced costs.Model ReferencesProduct Code<strong>6000</strong>/<strong>SSR</strong> Addressable Red <strong>Sounder</strong> & Base<strong>6000</strong>/SSW Addressable White <strong>Sounder</strong> & BaseNOTE: All the Model References above are looppowered addressable devices, supplied with a low profilebase.An optional deep base (below) can be purchasedseparately to allow surface wiring to be terminateddirectly into the base.29-982-7529-983-76No123Red Deep BaseWhite Deep BaseColour OptionsTone OptionsWarble 990Hz 250ms 665Hz 250msContinuous Tone at 990HzPulse Tone 990Hz 500ms Silence 500msNOTE: The tone and volume are selectable at thecontrol panel. Volume options - High-100, Mid-95, Low-75dB(A)5Deep Base Dimensions (mm)55.517114.4mmCompany Policy is one of continuous improvement, we reserve the right to change specification without prior notice<strong>Protec</strong> <strong>Fire</strong> <strong>Detection</strong> Plc, <strong>Protec</strong> House, Churchill Way, Nelson, Lancashire, BB9 6RTTel: 01282 717171 Fax: 01282 717273 Web: www.protec.co.uk Email: sales@protec.co.ukN 92-162-70 MED1059

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!