3300 Conventional Fire Alarm Control Panel - Protec Fire Detection

3300 Conventional Fire Alarm Control Panel - Protec Fire Detection

3300 Conventional Fire Alarm Control Panel - Protec Fire Detection

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

• Fully Compliant with EN54 Parts 2 & 4• Choice of 4 or 8 Zones• Manual or Automatic Device Indication• Zone Delays• Coincidence <strong>Detection</strong>• <strong>Fire</strong> Link Delay• Non-latching Zones• Zone Disablements• <strong>Alarm</strong> Disablements• <strong>Fire</strong> Link Disablement• User Walk Test<strong>3300</strong> <strong>Conventional</strong> <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panel</strong><strong>Fire</strong> <strong>Detection</strong> - Non AddressableThe <strong>3300</strong> series of conventionalcontrol panels has been designed toprovide a simple, user-friendlysolution, with inbuilt flexibilitypreviously only found in morecomplex addressable systems. With achoice of 4 or 8 detection zones the<strong>3300</strong> panel is ideal for small tomedium sized buildings such asIndustrial Units, Retail Units, Shops,Schools, ...All <strong>3300</strong> panels can be either surfaceor recessed mounted, with thecontrols and indications protectedfrom unauthorised access byentering a user access code. Thefunctions include clearly labelledsilence, reset, buzzer mute and soundalarms push buttons along withadditional facilities such as zone test,zone disablement, alarm disablement,delay disablement and fire linkdisablement.A particular feature of the <strong>3300</strong> <strong>Panel</strong>,is the ability to identify if a ‘FIRE’signal has been generated manuallyby a person activating a manual callpoint (MCP) or automatically from adetector. This knowledge enables anappropriate cause and effectsequence to be implemented such astime delays to allow for alarmverification for automatic detectors,but immediate alarms from MCPs.Cause and effect functions includecoincidence detection, zone delaysand/or fire link delay.Interconnection with other systems issimplified as zones can be configuredas ‘non-latching’, and there arededicated ‘remote alarm input’ and‘class change input’ terminals.Up to 8 repeater panels can beconnected to the <strong>3300</strong> panel on aserial communication link.The <strong>3300</strong> fire alarm control panelcomplies with EN54 parts 2 and 4.A D D R E S S I N G S A F E T Y S Y S T E M S W I T H I N T E L L I G E N C E


<strong>Fire</strong> <strong>Detection</strong> - Non Addressable<strong>3300</strong> Technical SpecificationPower Supply Mains 230V AC. Nominal ( + /_ 10%).Integral ChargerAuxiliary 24V outputMaximum Battery SizeMains FuseBattery FuseWorking VoltageCurrent ConsumptionNumber of Detector Zones1A switch mode, temperaturecompensated.24V DC, 100mA max.2 x 12V 3.3Ah.1A HRC ceramic 20mm.1.6A F 20mm.20V to 30V DC.15mA (24V DC) + Zone Load.4 or 8 depending on themodel purchased.Maximum Quiescent Zone LoadMaximum Number of DetectorsMaximum Number of Devices1.5mA per zone.MCP Series Resistor Value 180Ω + /_ 5%.Number of <strong>Alarm</strong> Circuits 4.20 per zone (smoke or heat).32 (MCP and Dets) per zone.+<strong>Alarm</strong> Circuit End Of Line Value 10kΩ 1/4W /_ 5%.Maximum <strong>Alarm</strong> LoadClass Change InputRemote <strong>Alarm</strong> Input150mA per circuit.Activates alarm outputs.Activates alarm outputs,internal buzzer and generalfire indicator.Maximum Zone Cable Length500 metres.Global Fault Contacts24V DC 1 A rating.Maximum Zone Cable Capacitance0.27µF.Global <strong>Fire</strong> Contacts24V DC 1 A rating.Maximum Zone Cable Resistance15Ω per conductor.Expansion Port Communications2 wire Data + 2 wire Power.Detector Circuit EOL ValuesResistive (8.2kΩ) orcapacitive (100µF/22Ω).Temperature RangeHumidity Limit0 to 40 Degrees Centigrade.85% Non-Condensing.3304, 3308 <strong>Fire</strong> <strong>Alarm</strong> <strong>Panel</strong>, <strong>3300</strong> <strong>Fire</strong> <strong>Alarm</strong> Repeat <strong>Panel</strong>3879538.5155.5154.52372348242163Dimensions in mmModel References3304 4 Zone <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panel</strong>3308 8 Zone <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panel</strong><strong>3300</strong>/RP <strong>Fire</strong> <strong>Alarm</strong> Repeat <strong>Panel</strong>Company policy is one of continuous improvement, we reserve the right to change specification without prior notice<strong>Protec</strong> <strong>Fire</strong> <strong>Detection</strong> Plc, <strong>Protec</strong> House, Churchill Way, Nelson Lancashire BB9 6RTTel: 01282 717171 Fax: 01282 717273 Web: www.protec.co.uk Email: sales@protec.co.ukN 92-167-75 MED1056


<strong>3300</strong> Optional EquipmentKEY3000/OPHT3000/OP3000/ION3000/TEMP643000/MCP3000/SSR2B6D024<strong>3300</strong>/RP Repeat panelThe <strong>3300</strong>/RP Repeat <strong>Panel</strong> mimics all theindications and user functionality of themain panel as detailed previously. Amaximum of 8 repeat panels can beconnected to the <strong>3300</strong> panel using theexternal expansion port communicationsusing 4 core screened cable +24V DC, 0V,Data+ and Data-.3100CCI Zonal Clean Contact InterfaceThe 3100CCI provides a clean contactoutput per zone and can be configured(using on board DIL switches) tooperate the relevant contacts onautomatic zone activations, manualzone activations, any zone activationsor any zone faults. To allowdifferentiation between manual orautomatic zone activations, <strong>Protec</strong>3000/MCP manual call points must befitted.3100FLI <strong>Fire</strong> Link InterfaceThe 3100FLI provides an open and shortcircuit monitored fire link, when used inconjunction with a 3100 <strong>Fire</strong> Link EOLPCB (WEFA348). The EOL device has asingle pole clean changeover contact,rated at 1A 24V DC.<strong>Fire</strong> Link delay time can be enabled onthe main panel and set-up locally onthe 3100/FL, between 0 and 10 minutes.Technical Specification: <strong>3300</strong>/RP 3100CCI 3100FLISupply Voltage20V to 30V DC20V to 30V DC20V to 30V DCQuiescent Current11mA8.5mA6mAMaximum Current25mA75mA30mAMaximum Clean Contact RatingN/A1A @ 24V DC1A @ 24V DCMaximum No Per <strong>Panel</strong> 811Serial Communications2 wire (plus power) 3100V1 Protocol

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!