Troubleshooting9 TroubleshootingCAUTIONPersonal injury or property damage resultingfrom troubleshooting.• Problems with no reference to a qualifiedspecialist may be rectified independently.• Other problems are only to be dealt with bya qualified specialist.Problem Possible causes RemedyMotor is not operating. Motor is malfunctioning.Motor change (specialist only) On-site motor connection is incorrect. Motor thermal protection switch hastriggered There is no current In the upward direction, the motorswitches off when the allowable torquelimit is exceeded (only with comfortswitch-off for icing)Reconnect as per wiring diagram(electricians only)Wait <strong>10</strong> to 15 minutes, then try againCheck the power fuse (electriciansonly)Issue a short downward command;When the unit moves down: stop theunit and check whether its path isblocked.If so: clear the blockage and issue adownward commandIf the motor stops again: teach-in themotor again for this product(specialists only)Bottom rail does not move to limitpositions A higher-level control command ispresent Motor switch-off positions are incorrect Guide rails are soiledAwait switch on/off delayReadjust the motor (specialists only)Remove soiling[B866866_0] - EN / 01.04.08 Page 11 of 12 Subject to change without notice.