Over heat of compressor[Gas shortage, defective dischargepipe sensor]Is discharge pipe sensorresistance value good?(page 43)NOConnector connection check, resistancevalue check, replacement of discharge pipesensorYESIs sufficient quantity of refrigerantcirculated?NODoes trouble persist aftercharging gas?NOCheck if there are anyplaces where gas is leaking.YESYESDefective outdoor unit PCBClogged capillary tube orstrainer, defective EEV, etc.Error of signal transmission[Wiring error including power cable, defective indoor/outdoor unit PCB]Does error persist after powerreset?NOTrouble by transient cause, not unit trouble.YESAre the lines connecting the indoorand outdoor units connectednormally?YESNOCorrect improper wire connection on indoor/outdoor unit.Is DC 0~Approx. 12V detectedbetween 2~3 terminals onindoor unit terminal block?NODefective indoor unit PCBYESIs DC 0~Approx. 12V detectedbetween2~3 terminals onoutdoor unit terminal block?NOCheck crossover wires.YESIs AC 220/230/240V appliedbetween 1~2 on the outdoor sideterminal block?NODefective indoor unit PCB. Check crossover wires.YESDefective outdoor unit PCB- 45 -