ModelSRK25ZG-S (Indoor unit)SRC25ZG-S (Outdoor unit)(220/230/240V)ItemModelSRK25ZG-SCooling capacity (1) W 2500 (500~3000)Heating capacity (1) W 3400 (500~4800)Power source1 Phase, 220-240V, 50HzCooling input kW 0.62 (0.1~0.97)<strong>Ru</strong>nning current (Cooling) A 3.1/3.0/2.9Heating input kW 0.93 (0.09~1.30)<strong>Ru</strong>nning current (Heating) A 4.5/4.3/4.1Inrush current A 4.5/4.3/4.1Operation data (1)COP Cooling: 4.03 Heating: 3.66SRC25ZG-SSound level Hi 36, Me 30, Lo 22 44CoolingPower level52 58Noise leveldBSound level Hi 36, Me 33, Lo 26 47HeatingPower level 54 62Exterior dimensionsHeight × Width × Depthmm 268 × 790 × 199 540 × 780 × 290Color Fine snow Stucco whiteNet weight kg 8.5 35Refrigerant equipmentCompressor type & Q’ty– RM-B5077MD1 (Rotary type) × 1Motor kW – 0.75Starting method – Line startingHeat exchanger Louver fins & inner grooved tubing Straight fins & inner grooved tubingRefrigerant controlCapillary tubes + Electronic expansion valveRefrigerant (3) kg R410A 0.9 (Pre-Charged up to the piping length of 15m)Refrigerant oil R 0.35 (MA68)Deice controlMicrocomputer controlAir handling equipmentFan type & Q’tyTangential fan × 1 Propeller fan × 1Motor W 38 24Air flow (at High)(Cooling) 7.6 30CMM(Heating)8.7 23Air filter, Q’ty Polypropylene net (washable) × 2 –Shock & vibration absorber – Cushion rubber (for compressor)Electric heater – –Operation controlOperation switchWireless-Remote control –Room temperature control Microcomputer thermostat –Pilot lampRUN (Green), TIMER (Yellow), HI POWER (Green), 3D AUTO (Green)Safety equipmentCompressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protectionRefrigerantpipingO.D mm (in) Liquid line: φ6.35 (1/4″) Gas line: φ9.52 (3/8″)Connecting methodFlare connectingAttached length of pipingLiquid line: 0.4 mGas line : 0.33 m–InsulationNecessary (Both sides)Connectable2 m (3 cores with Earth)Size × Core number1.5 mm 2 × 4 cores (Including earth cable)Connecting methodTerminal block (Screw fixing type)Drain hosePower source cordConnection wiringAccessories (included) Mounting kit, Clean filter (Allergen clear filter x1, Photocatalytic washable deodorizing filter x1)Optional partsInterface kitNotes (1) The data are measured at the following conditions.Item Indoor air temperature Outdoor air temperatureOperation DB WB DB WBStandardsCooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612Heating 20ºC – 7ºC 6ºC ISO-T1, JIS C9612The piping length is 7.5m.(2) The operation data are applied to the 220/230/240V districts respectively.(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.(Purging is not required even for the short piping.)(4) If the interface kit (SC-BIK-E) (sold separately) is connected to the terminals on the indoor unit’s circuit board, a wired remote control (sold separately)can be connected, a Super Link can be connected, and the unit can be turned on and off from a CNT terminal.- 3 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!