© Siemens AG 2011Selection of the <strong>gear</strong> <strong>units</strong>Guidelines for selectionService factors■ Overview (continued)Factor for prime mover f 2 Peak torque factor f 3Machine Factor for prime mover f 2Electric motors, hydraulic motors,turbinesPiston engines 4 – 6 cylinders,cyclic variation 1 : 100 to 1 : 200Piston engines 1 – 3 cylinderscyclic variation 1 : 1001.01.251.5Direction of load Peak torque factor f 3Load peaks per hour1 – 5 6 – 30 31 – 100 > 100Steady direction of load 0.67 0.86 0.93 1.13Alternating direction of load 0.93 1.26 1.46 1.66Thermal factor f 4(Gear <strong>units</strong> without auxiliary cooling or with fan)Ambient temperature t U Operating cycle per hour (E D )in °C in %100 80 60 40 2010 1.14 1.20 1.32 1.54 2.0420 1.00 1.06 1.16 1.35 1.7930 0.87 0.93 1.00 1.18 1.5640 0.71 0.75 0.82 0.96 1.2750 0.55 0.58 0.64 0.74 0.983(450) 655-7447info@pt-dstech.comwww.dstech.ca1275 Newton, local 15Boucherville, Qc,Canada, J4B 5H2Siemens MD 31.1 · 20113/7