<strong>Issue</strong> 2 Page 9<strong>8051</strong> 5.1 Compressor <strong>User</strong> GuideEXT ControlThe EXT buttons provide an insert point in the control voltage signal, after the bias control but beforerouting back to the channels.During normal operation the control voltages generated by the sidechain are internally connectedto the CV Link switched for routing back to the channels. In EXT mode the control voltage is takenfrom the rear connector instead of the sidechain outputs, allowing the unit to be slaved from asecond <strong>8051</strong> or 33609.There is no EXT Control with 88R(S) console mounted compressors (AM5052 & AM5265).PinFunction1 0V Reference9 CV send, sidechain A12 Remote power-on5 CV send, sidechain B13 CV return, sidechain B14 CV return, sidechain A15 24V ReferenceShort to pin 12 to pin 1 to take the unit out of standby mode remotely.CONTROLVOLTAGE I/OKEY INPUTPUSHINPUT 6PUSHINPUT 5PUSHINPUT 4PUSHINPUT 3PUSHINPUT 2PUSHINPUT 1PUSHWARNINGDISCONNECT MAINS LEADTO ISOLATE UNIT.NO USER SERVICEABLEPARTS INSIDEHAZARDOUS VOLTAGES INSIDEREFER TO MANUALSCHASSIS INTERNAL0VPLEASE SEEMANUALOUTPUT 6OUTPUT 5OUTPUT 4OUTPUT 3OUTPUT 2OUTPUT 1FUSE 1.6A A/S CERAMICINPUT VOLTAGE 100-250V ACINPUT FREQUENCY 47-63Hz