INPUT / OUTPUT / POWER SUPPLY / COMMUNICATION modules
INPUT / OUTPUT / POWER SUPPLY / COMMUNICATION modules
INPUT / OUTPUT / POWER SUPPLY / COMMUNICATION modules
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
MultiCon CMC I/O <strong>modules</strong>Output <strong>modules</strong> - SSRS8: 8 x SSR outputsS16: 16 x SSR outputsS24: 24 x SSR outputsThese <strong>modules</strong> are equipped with 8, 16 or 24 SSR outputs. May be used tocontrol executive device state in a simple on/off or PWM mode.MODULE PIN ASSIGNMENTS8Built-in outputs parameters in the PWM mode are:- Name - read-only output name given by the device,- Mode - this parameter allows the user to select method of the output operation,- Source - it contains the Logical channels list, the chosen one will be data sourcefor the relay,- Alarm level - allows the user to enter value at the output in times of alarm state,- Level - defines the source signal level at which the output switches the state(from low to high state or vice versa from high to low state), occurs for themode,- Lower level and Upper level - defines constant values on which depends relaystate switch (for Level mode: value), or allows to choose a logical channels fromthe list, which actual value will be data for relay state switch (for Level mode:channel),- Hysteresis - shifts relay levels with constant value, in the Relay operation mode,- On delay - time which elapses from the moment when source data meets therequirements for relay switch, to actual relay's switch to active state,- OFF delay - time which elapses from the moment when source data meets therequirement for relay switch, to actual relay's switch to passive state,- Min.ON time - minimal time when the relay is in the active state,- Min.OFF time - minimal time when the relay is in the passive state.TECHNICAL DATAS16S88 SSR outputsn01n02n03n04n05n06n07n08n09n10+10..24V DCGNDOUT1OUT2OUT3OUT4OUT5OUT6OUT7OUT8S1616 SSR outputsn01n02n03n04n05n06n07n08n09n10n11n12n13n14n15n16n17n18n19n20+10..24V DCGNDOUT1OUT2OUT3OUT4OUT5OUT6OUT7OUT8+10..24V DCGNDOUT9OUT10OUT11OUT12OUT13OUT14OUT15OUT16Pin description:1, 11, 21 : supply inputs for outputs1-8, 9-16 and 17-24 respectively (10-24V, max. 500 mA).10, 20, 30 : GND for outputs 1-8, 9-16and 17-24 (internally connected)2-9, 12-19, 21, 29 : SSR driver outputsS2424 SSR outputsn01n02n03n04n05n06n07n08n09n10n11n12n13n14n15n16n17n18n19n20n21n22n23n24n25n26n27n28n29n30+10..24V DCGNDOUT1OUT2OUT3OUT4OUT5OUT6OUT7OUT8+10..24V DCGNDOUT9OUT10OUT11OUT12OUT13OUT14OUT15OUT16+10..24V DCGNDOUT9OUT10OUT11OUT12OUT13OUT14OUT15OUT16S8 S16 S24Number of outputs 8 16 (in 2 groups with separate supply) 24 (in 3 groups with separate supply)Max. current sourceper outputpowered internally: 10 mA, sum limited to50 mA, powered externally: 100 mA, sumlimited to 500 mApowered internally: 10 mA, sum limited to powered internally: 10 mA, sum limited to50 mA for a group, powered externally: 50 mA for a group, powered externally:100 mA, sum limited to 500 mA for a group 100 mA, sum limited to 500 mA for a groupOutput method relay modes or PWM mode * relay modes or PWM mode * relay modes or PWM mode *Output High Levelvoltagepowered internally: ≥8Vpowered externally: ≥(Vext. - 0.5V)powered internally: ≥8Vpowered externally: ≥(Vext. - 0.5V)powered internally: ≥8Vpowered externally: ≥(Vext. - 0.5V)Overload protectionpowered internally: internal fuse 50 mA,powered externally: internal fuse 500 mApowered internally: internal fuse 50 mA(per group), powered externally: internalfuse 500 mA (per group)powered internally: internal fuse 50 mA(per group), powered externally: internalfuse 500 mA (per group)External output supply 30 V max. 30 V max. 30 VInsulation strength 1 min @ 500V AC 1 min @ 500V AC 1 min @ 500V ACWeight 32 g 42 g 69 gPart number M99-S8-001 M99-S16-001 M141-S24-00118* CMC updates output state every 100 mswww.multicon24.eu