11.07.2015 Views

INPUT / OUTPUT / POWER SUPPLY / COMMUNICATION modules

INPUT / OUTPUT / POWER SUPPLY / COMMUNICATION modules

INPUT / OUTPUT / POWER SUPPLY / COMMUNICATION modules

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MultiCon CMC I/O <strong>modules</strong>Output <strong>modules</strong> - SSRS8: 8 x SSR outputsS16: 16 x SSR outputsS24: 24 x SSR outputsThese <strong>modules</strong> are equipped with 8, 16 or 24 SSR outputs. May be used tocontrol executive device state in a simple on/off or PWM mode.MODULE PIN ASSIGNMENTS8Built-in outputs parameters in the PWM mode are:- Name - read-only output name given by the device,- Mode - this parameter allows the user to select method of the output operation,- Source - it contains the Logical channels list, the chosen one will be data sourcefor the relay,- Alarm level - allows the user to enter value at the output in times of alarm state,- Level - defines the source signal level at which the output switches the state(from low to high state or vice versa from high to low state), occurs for themode,- Lower level and Upper level - defines constant values on which depends relaystate switch (for Level mode: value), or allows to choose a logical channels fromthe list, which actual value will be data for relay state switch (for Level mode:channel),- Hysteresis - shifts relay levels with constant value, in the Relay operation mode,- On delay - time which elapses from the moment when source data meets therequirements for relay switch, to actual relay's switch to active state,- OFF delay - time which elapses from the moment when source data meets therequirement for relay switch, to actual relay's switch to passive state,- Min.ON time - minimal time when the relay is in the active state,- Min.OFF time - minimal time when the relay is in the passive state.TECHNICAL DATAS16S88 SSR outputsn01n02n03n04n05n06n07n08n09n10+10..24V DCGNDOUT1OUT2OUT3OUT4OUT5OUT6OUT7OUT8S1616 SSR outputsn01n02n03n04n05n06n07n08n09n10n11n12n13n14n15n16n17n18n19n20+10..24V DCGNDOUT1OUT2OUT3OUT4OUT5OUT6OUT7OUT8+10..24V DCGNDOUT9OUT10OUT11OUT12OUT13OUT14OUT15OUT16Pin description:1, 11, 21 : supply inputs for outputs1-8, 9-16 and 17-24 respectively (10-24V, max. 500 mA).10, 20, 30 : GND for outputs 1-8, 9-16and 17-24 (internally connected)2-9, 12-19, 21, 29 : SSR driver outputsS2424 SSR outputsn01n02n03n04n05n06n07n08n09n10n11n12n13n14n15n16n17n18n19n20n21n22n23n24n25n26n27n28n29n30+10..24V DCGNDOUT1OUT2OUT3OUT4OUT5OUT6OUT7OUT8+10..24V DCGNDOUT9OUT10OUT11OUT12OUT13OUT14OUT15OUT16+10..24V DCGNDOUT9OUT10OUT11OUT12OUT13OUT14OUT15OUT16S8 S16 S24Number of outputs 8 16 (in 2 groups with separate supply) 24 (in 3 groups with separate supply)Max. current sourceper outputpowered internally: 10 mA, sum limited to50 mA, powered externally: 100 mA, sumlimited to 500 mApowered internally: 10 mA, sum limited to powered internally: 10 mA, sum limited to50 mA for a group, powered externally: 50 mA for a group, powered externally:100 mA, sum limited to 500 mA for a group 100 mA, sum limited to 500 mA for a groupOutput method relay modes or PWM mode * relay modes or PWM mode * relay modes or PWM mode *Output High Levelvoltagepowered internally: ≥8Vpowered externally: ≥(Vext. - 0.5V)powered internally: ≥8Vpowered externally: ≥(Vext. - 0.5V)powered internally: ≥8Vpowered externally: ≥(Vext. - 0.5V)Overload protectionpowered internally: internal fuse 50 mA,powered externally: internal fuse 500 mApowered internally: internal fuse 50 mA(per group), powered externally: internalfuse 500 mA (per group)powered internally: internal fuse 50 mA(per group), powered externally: internalfuse 500 mA (per group)External output supply 30 V max. 30 V max. 30 VInsulation strength 1 min @ 500V AC 1 min @ 500V AC 1 min @ 500V ACWeight 32 g 42 g 69 gPart number M99-S8-001 M99-S16-001 M141-S24-00118* CMC updates output state every 100 mswww.multicon24.eu

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!