11.07.2015 Views

INSTALLATION OPERATION MAINTENANCE - Coastal Winair

INSTALLATION OPERATION MAINTENANCE - Coastal Winair

INSTALLATION OPERATION MAINTENANCE - Coastal Winair

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

General InformationProgrammable Zone Sensor - (BAYSENS019B)This 7 day programmable sensor features 2, 3 or 4 periodsfor Occupied or Unoccupied programming per day. If thepower is interrupted, the program is retained in permanentmemory. If power is off for an extended period of time, onlythe clock and day may have to be reset.The Zone Sensor allows selection of 2, 3 or 4 system modes(Heat, Cool, Auto, and Off), two fan modes (On and Auto). Ithas dual temperature selection with programmable start timecapability.The occupied cooling set point ranges between 45 and 98degrees Fahrenheit. The heating set point ranges between43 and 96 degrees Fahrenheit.A liquid crystal display (LCD) displays zone temperature,temperature set points, day of the week, time, and operationalmode symbols.The Option Menu is used to enable or disable applicablefunctions, i.e.; Morning Warm-up, Economizer minimum positionoverride during unoccupied status, Fahrenheit or Centigrade,Supply air tempering, Remote zone temperature sensor,12/24 hour time display, Smart fan, and Computed recovery.During an occupied period, an auxiliary relay rated for 1.25amps @ 30 volts AC with one set of single pole double throwcontacts is activated.Status Inputs (4 Wires Optional)The ZSM can be wired to receive four (4) operating statussignals from the RTRM (HEAT, COOL, SYSTEM “ON”, SER-VICE).Four (4) wires from the RTRM should be connected tothe appropriate terminals (7, 8, 9 & 10) on the ZSM.Remote Zone Sensor (BAYSENS013B)This electronic sensor features remote zone sensing andtimed override with override cancellation. It is used with aTrane Integrated Comfort TM building management system.Remote Zone Sensor (BAYSENS014B)This electronic sensor features single setpoint capability andtimed override with override cancellation. It is used with aTrane Integrated Comfort TM building management system.Remote Zone Sensor (BAYSENS016A)This bullet type temperature sensor can be used for; outsideair (ambient) sensing, return air temperature sensing, supplyair temperature sensing, remote temperature sensing (uncovered.Wiring procedures vary according to the particularapplication and equipment involved. Refer to the unit’s wiringdiagrams for proper connections.BAYSTAT036ASingle Stage - 1 Heat/1 CoolBAYSTAT037AMulti Stage - 2 Heat/2 Cool - Can be Used for EconomizerOperationBAYSENS025ARemote sensor for BAYSTAT036A and BAYSTAT037AHigh Temperature Sensor (BAYFRST001A)This sensor connects to the RTRM Emergency Stop Inputon the LTB and provides high limit “shutdown” of the unit.The sensor is used to detect high temperatures due to firein the air conditioning or ventilation ducts. The sensor isdesigned to mount directly to the sheet metal duct. Each kitcontains two sensors. The return air duct sensor(X1310004001) is set to open at 135 F. The supply air ductsensor (X1310004002) is set to open at 240 F. The controlcan be reset after the temperature has been lowered approximately25 F below the cutout setpoint.Evaporator Frost Control(ReliaTel Option)This input incorporates the Frostat control (FOS)mounted in the indoor coil circuit and can be activated byclosing a field supplied contact installed in parallel withthe FOS.If this circuit is open before the compressor is started, thecompressor will not be allowed to operate. Anytime thiscircuit is opened for 1 continuous second during compressoroperation, the compressor for that circuit is immediatelyturned “Off”. The compressor will not be allowed torestart for a minimum of 3 minutes should the FOS close.(Electro Mechanical Option)This input incorporates the Frostat control (FOS)mounted in the indoor coil circuit and can be activated byopening a field supplied contact installed in series with theFOS.If this circuit is open before the compressor is started, thecompressor will not be allowed to operate. Anytime thiscircuit is opened during compressor operation, the compressorfor that circuit is immediately turned “Off”. Thecompressor will restart when the FOS closes.Remote Zone Sensor (BAYSENS017B)This electronic sensor can be used with BAYSENS006B,008B, 010B, 019B Remote Panels. When this sensor is wiredto a BAYSENS019B Remote Panel, wiring must be 18 AWGShielded Twisted Pair (Belden 8760 or equivalent). Refer toThe specific Remote Panel for wiring details.Electro Mechanical ControlThe unit must have a Thermostat to operate.7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!