11.07.2015 Views

Columns for HPLC - Western Analytical

Columns for HPLC - Western Analytical

Columns for HPLC - Western Analytical

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Columns</strong> <strong>for</strong> <strong>HPLC</strong><strong>Columns</strong> <strong>for</strong> <strong>HPLC</strong><strong>Analytical</strong> columns packed with NUCLEOSIL ®Ordering in<strong>for</strong>mation · <strong>Analytical</strong> columns with NUCLEOSIL ® C 4Length → 70 mm 100 mm 125 mm 150 mm 250 mm Guard columnsNUCLEOSIL ® 300-5 C 4Particle size 5 µm, pore size 300 Å; butyl phase, endcapped, ~2% C; eluent in column acetonitrile / waterChromCart ® columns2 mm ID 721784.20 721627.20 721667.20 721607.303 mm ID 721627.30 721667.30 721607.304 mm ID 721627.40 721667.40 721607.404.6 mm ID 721627.46 721647.46 721667.46 721607.40Microbore columns 1)1 mm ID 717044.10 717047.10 717055.10 717058.10EC columns 2)4 mm ID 720059.40 721607.404.6 mm ID 720059.46 721607.40NUCLEOSIL ® 300-7 C 4Particle size 7 µm, pore size 300 Å; butyl phase, endcapped, ~2% C; eluent in column acetonitrile / waterEC columns 2)4 mm ID 720060.404.6 mm ID 720060.46ChromCart ® guard column cartridges (8 mm) in packs of 3, all other columns in packs of 1.1) On request, Microbore columns are also available in lengths of 40, 60, 200 and 300 mm and with 0.15, 0.3, 0.4, 0.5, 0.75 and 1.5 mm ID.Guard columns <strong>for</strong> Microbore columns on request.2) As guard columns <strong>for</strong> EC columns use ChromCart ® guard column cartridges with guard column adaptor EC (Cat. No. 721359).Dimethyl phases -(CH 3 ) 2Dimethyl phases are suited <strong>for</strong> reversed phase chromatographyand ion-pairing chromatography. Retention times on thedimethyl phase are much shorter than <strong>for</strong> the other RP phases.Ordering in<strong>for</strong>mation · <strong>Analytical</strong> columns with NUCLEOSIL ® C 2Length → 125 mm 250 mm Guard columnsNUCLEOSIL ® 100-7 C 2Particle size 7 µm, pore size 100 Å; dimethyl phase, not endcapped, 3.5 % C; eluent in column acetonitrile / waterChromCart ® columns4 mm ID 721873.40 721874.40 721069.40EC columns 1)4 mm ID 720089.40 721069.404.6 mm ID 720089.46 721069.40ChromCart ® guard column cartridges (8 mm) in packs of 3, all other columns in packs of 1.1) As guard columns <strong>for</strong> EC columns use ChromCart ® guard column cartridges with guard column adaptor EC (Cat. No. 721359).6.7.05Each column is individually tested and supplied with test chromatogram and test conditions48www.mn-net.comMN

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!