11.07.2015 Views

SMP Calibration Kits - Spectrum Elektrotechnik GmbH

SMP Calibration Kits - Spectrum Elektrotechnik GmbH

SMP Calibration Kits - Spectrum Elektrotechnik GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

kits.pm6<strong>Calibration</strong> <strong>Kits</strong>adjusting the adjacent in-specification connector interfaces that is usually recessed, as allowed,to perfect 50 Ohms lines. So length adjustments of 0.0004 inches (0.01mm) can be achieved,when all center contacts have been purchased. A Center Contact Insertion Tool helps to alignand connect the center contact.The <strong>Calibration</strong> <strong>Kits</strong> are delivered with a disc supplying data on the properties of the <strong>Kits</strong>'components. <strong>Kits</strong> are available for the Network Analyzers of Hewlett Packard and Wiltronand can be divided into two groups: The Standard LRL <strong>Calibration</strong> Kit, and the ProfessionalLRL <strong>Calibration</strong> Kit. The Instrument Cases for both of these <strong>Calibration</strong> <strong>Kits</strong> are identical.The customer may start with the Standard <strong>Calibration</strong> Kit and fill the empty spots at a laterstage, to end up with the Professional <strong>Calibration</strong> Kit.STANDARD LRL CALIBRATION KIT: A <strong>Calibration</strong> Kit contains as a minimum twoShorts (male and female), two Throughlines each (female/female, male/female, male/male) indifferent lengths and a Disk for the <strong>Calibration</strong> Characteristics. The Disc is supplied either forthe Scalar Network Analyzers of Hewlett Packard, or Wiltron, and is ready to be used.PROFESSIONAL LRL CALIBRATION KIT: Besides the components, as supplied withthe Standard Kit, it also contains Interface Gauges for measuring the center condutor location,<strong>Calibration</strong> Blocks for those Interface Gauges, and a Torque Wrench.VERIFICATION KITS: To verify that the network analyzer system is working properly,the measuring of known devices, other than the calibration standards, is a straightforwardmethod. <strong>Spectrum</strong> <strong>Elektrotechnik</strong> <strong>GmbH</strong> is offering Verification <strong>Kits</strong> that consist ofprecision airlines and mismatch airlines. Traceable measurement data are shipped with each kit.TEST CABLES: Vector network analizers require electrically stable cable assemblies formeasurement in very critical areas, such as Phase, Amplitude and VSWR. Cables have tomaintain calibration data, even when subjected to bending and twisting which can introducedistorting parameters. The cable assembly needs to be flexible without being flaccid. TheCables of Types 16, 18 and 22, as described in the Phase Stable Cable Assemblies’ Sectionare ideal for this application. One end of the Assembly will usually be terminated with anNMD 2.4mm, 2.9mm, or 3.5mm, 7mm or N connector, as needed for connecting directlywith the RF output of the network analyzer. These NMD Connectors are designed with alarger than standard coupling nut for greater stability. The other end of the ANA - Assemblycan be terminated with the proper Test Connector, as needed in the setup.ADAPTERS: <strong>Spectrum</strong> <strong>Elektrotechnik</strong> <strong>GmbH</strong> manufactures a large variety of adapters. Whereexisting test cables are to be used, between series instrument-grade adapters to those 2.4mm,2.9mm, 3.5mm, 7mm, or N-type test port or ANA cable connectors are offered. NMDInstrument-Grade Adapters are supplied when the network analizer test port needs to bechanged to another connector series. The NMD Adapters are designed with this larger thanstandard coupling nut for greater stability.<strong>Spectrum</strong> <strong>Elektrotechnik</strong> <strong>GmbH</strong> P.O. Box 45 05 33, 80905 Munich, Germany Tel. (89) 354 804-0, Fax (89) 354 804-90 (Country Code: 49)11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!