LRL/TRL <strong>Calibration</strong> KitOrderingInformationThe LRL / TRL CALIBRATION KITS can be divided into two groups: The Standard<strong>Calibration</strong> Kit and The Professional <strong>Calibration</strong> Kit.The Instrument Cases for both of these <strong>Calibration</strong> <strong>Kits</strong> are identical. You may start with theStandard <strong>Calibration</strong> Kit and fill the empty spots at a later stage, to end up with the Professional<strong>Calibration</strong> Kit.The STANDARD CALIBRATION KIT: It contains all the components needed for acalibration in the subject connector series, and the software configuration medium. For all theadapters sets of center contacts are supplied, as necessary to build ideal airlines. The differentlengths of center contacts are needed to build those ideal airlines, including the matingconnectors of the ANA or its cable assemblies. Although these are instrument grade connectors,the center contact may be recessed, as allowed in the applicable connector specification.Using now the correct overlength of the airline center conductor, the recess-gaps at the matingcenter conductors are filled. With the Standard <strong>Calibration</strong> Kit, for which connector gaugesare not supplied, the overlength center contacts should not be used. It is only proper to usethem when the actual recession of the mating connectors has been measured, otherwise themating connectors can be damaged.The PROFESSIONAL CALIBRATION KIT: Besides the components supplied with theStandard <strong>Calibration</strong> Kit, sets of interface gauges for the center conductor location dimensions,calibration block, wrenches, and a torque wrench are added. Four empty spaces can be filledwith optional adapters, individually specified.GB - C D E F - H I K LB: to be replaced withone of the followingletters for theoption required.S = Standard KitP = Professional Kit40CD: to be replacedwith one of thefollowing numbers/lettersfor theoption required.ANA Output Conn.or Cable Conn.respectively.24 = 2.4mm female29 = 2.9mm female35 = 3.5mm female70 = 7mmN0 = N femaleSM = <strong>SMP</strong>F: Resolution of theInterface Gauges.Please replace Fwith one of thefollowing letters forthe option required.Resolutionmm inchesH = 0.005J = 0.0001K = 0.01 L = 0.001E: to be replaced with one of the T = 0.001following letters for the optionrequired.Digital GaugeD =0.01mm/ 0.0005"<strong>Calibration</strong> Kit suggested for:T = Hewlett Packard ANA For the StandardL = Wiltron ANA<strong>Calibration</strong> Kit F = 0.HI: to be replacedwith one of thefollowing numbers/lettersfor theoption required.Additional Adaptersfrom ANA OutputConnector Series toone on the followingSeries: (1 pce. each:f/f, f/m, m/f and m/m).24 = 2.4mm29 = 2.9mm35 = 3.5mm70 = 7.0mmN0 = NKL: Upper Fre-----quency Limit ofthis Kit. Pleasereplace KL withone of the....following numbersfor the optionrequired.18 = 18.0 GHz26 = 26.5 GHz35 = 35.0 GHz40 = 40.0 GHz50 = 50.0 GHzIf Adapters, other than to <strong>Calibration</strong>Connector Series are required, a specialCode will be submitted.<strong>Spectrum</strong> <strong>Elektrotechnik</strong> <strong>GmbH</strong> P.O. Box 45 05 33, 80905 Munich, Germany Tel. (89) 354 804-0, Fax (89) 354 804-90 (Country Code: 49)trefli.pm6
Section 1.3<strong>Calibration</strong> <strong>Kits</strong><strong>Calibration</strong> <strong>Kits</strong>9 f.f.1.OPEN-SHORT-LOAD -THROUGHLINE KITSa) INFORMATION ON ALL KITS 13b) <strong>SMP</strong> CALIBRATION KIT 23Line Reflective Line2. LRL/TRL KITS 35Through Reflective Line3. VERIFICATION KITS 41trefli.pm6<strong>Spectrum</strong> <strong>Elektrotechnik</strong> <strong>GmbH</strong> P.O. Box 45 05 33, 80905 Munich, Germany Tel. (89) 354 804-0, Fax (89) 354 804-90 (Country Code: 49)41