11.07.2015 Views

7-9 Banbury Road - Central Administration - University of Oxford

7-9 Banbury Road - Central Administration - University of Oxford

7-9 Banbury Road - Central Administration - University of Oxford

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

13 th October 19877-13 <strong>Banbury</strong> <strong>Road</strong>:“Construction <strong>of</strong> two paths between Nos. 7 and 13 and one ramp with handrails for disabledpersons to No.9.” On computer, record no. 81 and 82. Covers the majority <strong>of</strong> the paths currently out front, including horizontal connectingpaths.30 th April 1996- 2 nd December 19977-19 <strong>Banbury</strong> <strong>Road</strong>:“Conversion <strong>of</strong> unused area to 3no. <strong>of</strong>fices, removal <strong>of</strong> internal partitions, insertion <strong>of</strong> newstair and improvement <strong>of</strong> means <strong>of</strong> escape.”Unclear where in the building this is, maybe in the basement <strong>of</strong> one <strong>of</strong> the buildings?19 th February 19977 and 9 <strong>Banbury</strong> <strong>Road</strong>:“Conversion <strong>of</strong> attic to <strong>of</strong>fice space.”Affects eastern half <strong>of</strong> ro<strong>of</strong> only (the rear “hip” <strong>of</strong> the ro<strong>of</strong>).2 “Velux” ro<strong>of</strong> windows inserted on attic level.Internal brick chimney stack and partitions removed on attic level.Timber staircase on south end removed, but retained on north.New staircase on southern end, curves upwards from W to N, rather than N to E likethe old one. Partition placed behind it (N) on 1 st floor.18 th July 19977 <strong>Banbury</strong> <strong>Road</strong>:“Insertion <strong>of</strong> glazed screen to stairwell.”Glazed door and surrounding screen at ground-floor level, just before main stairwell.“…separates occupied areas (staff) from public areas (fire risk) and securityimprovement.”26 th April 20107 <strong>Banbury</strong> <strong>Road</strong>:“Installation <strong>of</strong> data and electrical services, including emergency lighting installations.”Rationalises existing wiring routes and provision, replacing intrusive wiring (such aswires attached directly to joinery) with less intrusive trunking.7 and 9 <strong>Banbury</strong> <strong>Road</strong>, <strong>Oxford</strong>Conservation Plan, May 2012 34

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!