11.07.2015 Views

safety in railway tunnels - ERA

safety in railway tunnels - ERA

safety in railway tunnels - ERA

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

(b) This consistency has been checked <strong>in</strong> relation to the development of the specifications with<strong>in</strong> thisTSI, its <strong>in</strong>terfaces with respect to the systems <strong>in</strong> which it is <strong>in</strong>tegrated and also the operat<strong>in</strong>g rules forthe <strong>railway</strong>.(c) Tak<strong>in</strong>g account of all the applicable essential requirements, the basic parameters related to <strong>safety</strong> <strong>in</strong><strong>railway</strong> <strong>tunnels</strong> are set out for the subsystems <strong>in</strong>frastructure, energy and roll<strong>in</strong>g stock <strong>in</strong> section 4.2 ofthis TSI. The operational requirements and responsibilities are set out <strong>in</strong> the OPE TSI and <strong>in</strong> section 4.4of this TSI.4.2. Functional and technical specifications of the subsystems(a) In the light of the essential requirements <strong>in</strong> Chapter 3, the functional and technical specifications ofthose aspects specific to tunnel <strong>safety</strong> <strong>in</strong> the above-mentioned subsystems are as follows:4.2.1. Subsystem Infrastructure4.2.1.1. Prevent unauthorised access to emergency exits and technical roomsThis specification applies to all <strong>tunnels</strong>.(a) Unauthorised access to technical rooms shall be prevented.(b) Where emergency exits are locked for security purposes, it shall always be possible to open themfrom <strong>in</strong>side.4.2.1.2. Fire resistance of tunnel structuresThis specification applies to all <strong>tunnels</strong>.(a) In the event of fire, the <strong>in</strong>tegrity of the tunnel l<strong>in</strong><strong>in</strong>g shall be ma<strong>in</strong>ta<strong>in</strong>ed for a period of timesufficiently long to permit self-rescue, evacuation of passengers and staff and <strong>in</strong>tervention of emergencyresponse services. That period of time shall be <strong>in</strong> accordance with the evacuation scenario and reported<strong>in</strong> the Emergency Plan.(b) In the cases of immersed <strong>tunnels</strong> and <strong>tunnels</strong> which can cause the collapse of importantneighbour<strong>in</strong>g structures, the tunnel ma<strong>in</strong> structure shall withstand the temperature of the fire for aperiod of time allow<strong>in</strong>g evacuation of the endangered tunnel zones and neighbour<strong>in</strong>g structures. Thisperiod of time shall be reported <strong>in</strong> the emergency plan.4.2.1.3. Fire reaction of build<strong>in</strong>g materialThis specification applies to all <strong>tunnels</strong>.(a) This specification applies to construction products and build<strong>in</strong>g elements <strong>in</strong>side <strong>tunnels</strong>.15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!