4.2.2.3. Electricity supplyThis specification applies to all <strong>tunnels</strong> of more than 1 km length.(a) The electricity power distribution system <strong>in</strong> the tunnel shall be suitable for emergency responseservices equipment <strong>in</strong> accordance with the emergency plan for the tunnel. (Some national emergencyresponse services groups may be self-sufficient <strong>in</strong> relation to power supply. In this case, the option ofnot provid<strong>in</strong>g power supply facilities for the use of such groups may be appropriate. Such a decision,however, must be described <strong>in</strong> the emergency plan.)4.2.2.4. Requirements for electrical cables <strong>in</strong> <strong>tunnels</strong>This specification applies to all <strong>tunnels</strong> of more than 1 km length.(a) In case of fire, exposed cables shall have the characteristics of low flammability, low fire spread, lowtoxicity and low smoke density. These requirements are fulfilled when the cables fulfil as a m<strong>in</strong>imum therequirements of classification B2 CA , s1a, a1, as per Commission Decision 2006/751/EC 8 .4.2.2.5. Reliability of electrical <strong>in</strong>stallationsThis specification applies to all <strong>tunnels</strong> of more than 1 km length.(a) Electrical <strong>in</strong>stallations relevant for <strong>safety</strong> (Fire detection, emergency light<strong>in</strong>g, emergencycommunication and any other system identified by the Infrastructure Manager or contract<strong>in</strong>g entity asvital to the <strong>safety</strong> of passengers <strong>in</strong> the tunnel) shall be protected aga<strong>in</strong>st damage aris<strong>in</strong>g frommechanical impact, heat or fire.(b) The distribution system shall be designed to enable the system to tolerate unavoidable damage by(for example) energiz<strong>in</strong>g alternative l<strong>in</strong>ks.(c) Autonomy and reliability: an alternative power supply shall be available for an appropriate period oftime after failure of the ma<strong>in</strong> power supply. The time required shall be consistent with the evacuationscenarios and reported <strong>in</strong> the Emergency Plan.4.2.3. Subsystem roll<strong>in</strong>g stock(a) In the context of this TSI the subsystem roll<strong>in</strong>g stock is subdivided <strong>in</strong>to the follow<strong>in</strong>g categories.(1) Category A passenger roll<strong>in</strong>g stock (<strong>in</strong>clud<strong>in</strong>g passenger locomotives) for operation on l<strong>in</strong>eswith<strong>in</strong> the scope of this TSI, where the distance between fire fight<strong>in</strong>g po<strong>in</strong>ts or the length of<strong>tunnels</strong> does not exceed 5km.(2) Category B passenger roll<strong>in</strong>g stock (<strong>in</strong>clud<strong>in</strong>g passenger locomotives) for operation <strong>in</strong> all<strong>tunnels</strong> on the l<strong>in</strong>es with<strong>in</strong> the scope of this TSI, irrespective of the length of the <strong>tunnels</strong>.8 Commission Decision 2006/751/EC of 27 October 2006 amend<strong>in</strong>g Decision 2000/147/EC implement<strong>in</strong>g CouncilDirective 89/106/EEC as regards the classification of the reaction-to-fire performance of construction products (OJL 305, 4.11.2006, p. 8–12).22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!