University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue14. Clear Space at Doors - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Areas noted in compliance:Floor or landing is level and clear (2% max. slope).60” min. clear space in direction of door swing.44” min. clear space opposite direction of door swing (48” with latch and closer).Minimum strike side clearance on PULL side of door: 24” exterior doors.Areas not meeting new construction standards:Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer. (11” to the paper toweldispenser.)Recommendation:Relocate the paper towel dispenser / hand dryer.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-14-1 (originally 0052)24