University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue19. Urinals - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Areas noted in compliance:A clear floor space that is a minimum 30” wide by 48” deep is provided in front of the urinal to allow forward approach.5 lb max. pressure to operate valve.Walls within 24” of front and sides of urinals are smooth, hard and non-absorbent to 48” height, and are not adverselyaffected by moisture.Areas not meeting new construction standards:17” maximum urinal rim height above the finished floor. (24-3/4”.)14” minimum projection and 17” maximum projection from the wall. (12-1/2”.)44” maximum height to flush valve above finished floor. (52-1/2”.)Recommendation:Replace/Install urinal.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-19-1 (originally 0059)34