27.11.2012 Views

www.calibration -online.com

www.calibration -online.com

www.calibration -online.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>www</strong>.<strong>calibration</strong>-<strong>online</strong>.<strong>com</strong><br />

Solutions pour la Calibration<br />

Avionique, Pression, Température<br />

Applications<br />

Calibrations of thermometers<br />

Temperature measurements within the scope of quality<br />

assurance<br />

Measurements in the service and maintenance sector<br />

Long-term monitoring and <strong>online</strong> documentation<br />

Special Features<br />

High accuracy of 0.03 °C with Pt 100<br />

One- and two- channel version available<br />

Connection of various types of probes possible<br />

Optionally with Ex-approval<br />

Description<br />

The universal hand-held thermometer model CTH 6500,<br />

which has been designed for demanding mobile tempera-<br />

ture measurements, features outstanding precision and<br />

flexibility and is extremely easy to use.<br />

Besides Pt 100 resistance thermometers it also processes<br />

the signals of typical thermocouples. Thus it is possible to<br />

measure temperatures ranging from -200 °C to 1760 °C.<br />

Due to its high accuracy of 0.03 °C in the range of -100 °C to<br />

150 °C this thermometer can be used as a reference<br />

measuring instrument in the biotechnological, pharmaceuti-<br />

cal and food industries and is therefore ideally suited for all<br />

maintenance and service tasks.<br />

Low-drift measuring amplifiers ensure that errors of meas-<br />

urement are minimised, and convenient, user-friendly<br />

adjustment functions considerably simplify adjustments and<br />

<strong>calibration</strong>s:<br />

Calibration by code for a fast adaptation of standard<br />

probes via characteristic hex numbers<br />

10/05/2010<br />

Testing and<br />

Calibration Technology<br />

Hand-Held Thermometer<br />

Model CTH 6500<br />

Model CTH 6500-Ex<br />

Hand-Held Thermometer CTH 6500<br />

WIKA Data Sheet CT 55<br />

Physical <strong>calibration</strong> of probe and display at one, two or<br />

three test temperatures<br />

This way it is possible to reduce measuring errors to a<br />

minimum and to ensure a high display accuracy.<br />

Further characteristic features:<br />

Easy to use<br />

Large display with double temperature indication and bar<br />

graph<br />

Min/Max value for the monitoring of the temperature<br />

limits<br />

Mean value function for statistical evaluations<br />

"Fast mode" enabling faster measurements within 4/s<br />

Optional channel can be turned off to give a clearer view<br />

of the displayed data<br />

Recording and display of temperature cycles with the<br />

help of the SmartGraph software<br />

Excellent price/performance ratio


Characteristic features of the Hand-Held Thermometers<br />

CTH 6500<br />

Operating functions<br />

In the setup menu a menu point can be selected and<br />

changed using the up and down (1) keys. Enter (3) and<br />

ESC (2) can be used for confirmation and termination.<br />

Large LCD display<br />

Membrane<br />

keypad<br />

1. Connection port<br />

for 1 st probe<br />

RS 232 connection port<br />

for PC<br />

2. Connection port<br />

for 2 nd probe<br />

10/05/2010<br />

Moveable clip for stand-up<br />

and hanging position of the<br />

instrument<br />

Probe retainer<br />

The intuitive menu is divided into two levels:<br />

Main menu for the selection of the basic functions and<br />

parameter menu for the setting of the parameters.<br />

Main menu of the CTH 6500<br />

Typical temperature probes<br />

Penetration probe<br />

CTP 9895<br />

Immersion probe<br />

CTP 9830<br />

Parameter menu of the CTH 6500<br />

Surface probe<br />

CTP 9865


Specifications CTH 6500 CTH 6500-Ex EEX ib II B T4<br />

Probe types<br />

Inputs<br />

Measuring ranges<br />

Pt 100<br />

Thermocouples<br />

Humidity<br />

Flow<br />

Measurement uncertainties 1)<br />

Pt 100<br />

TC K, J, L, N and T<br />

TC R and S<br />

Humidity<br />

Flow<br />

Resolution<br />

Display Interface<br />

2) Power supply<br />

Operating time<br />

Ambient temperature<br />

Dimensions<br />

Weight<br />

10/05/2010<br />

Pt 100, thermocouples<br />

Humidity, flow<br />

1 or 2<br />

-200 °C to 850 °C<br />

-200 °C to 1760 °C<br />

0 % to 100 %<br />

0 to 40 m/s<br />

0.03 °C from -100 °C to 150 °C<br />

0.05 °C from -200 °C to 200 °C<br />

0.1 % of reading above 200 °C<br />

0.2 °C from 0 °C to 200 °C<br />

0.5 °C from 200 °C to 1000 °C<br />

1 °C above 1000 °C<br />

1 °C + 0.1 % of reading<br />

1.5 % relative humidity<br />

0.5 % FS<br />

0.01 °C up to 200 °C, then 0.1 °C<br />

Two-line LCD display<br />

RS 232<br />

9 V battery or rechargeable battery<br />

approx. 20 h with battery<br />

0 °C to 40 °C<br />

200 mm x 85 mm x 40 mm<br />

300 g<br />

1) The measurement uncertainty is stated for the whole measuring chain after adjustment and <strong>calibration</strong>.<br />

2) The Ex instrument also has an RS 232 interface, which, however, must not be used in potentially explosive atmospheres.<br />

Pt 100<br />

1 or 2<br />

-200 °C to 850 °C<br />

-<br />

-<br />

-<br />

0.03 °C from -100 °C to 150 °C<br />

0.05 °C from -200 °C to 200 °C<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

0.01 °C up to 200 °C then 0.1°C<br />

Two-line LCD display<br />

(RS 232)<br />

9 V battery or rechargeable battery<br />

approx. 20 h with battery<br />

0 °C to 40 °C<br />

200 mm x 85 mm x 40 mm<br />

Accessories/Options CTH 6500 CTH 6500-Ex EEX ib II B T4<br />

Second input<br />

Pt 100 immersion probe CTP 9825<br />

-200 °C to 500 °C, 3 x 300 mm<br />

Pt 100 immersion probe CTP 9830 4)<br />

-200 °C to 500 °C, 3 x 300 mm<br />

Pt 100 penetration probe CTP 9895<br />

-200 °C to 500 °C, 4 x 300 mm<br />

Pt 100 surface probe CTP 9865<br />

-30 °C to 300 °C, 6 x 150 mm<br />

TC K immersion probe CTP 9125<br />

-200 °C to 1100 °C, 3 x 500 mm<br />

Combined temperature/humidity probe CTP 9025<br />

-30 °C to 80 °C / 0 % rel. humidity to 100 % rel. humidity,<br />

20 x 120 mm<br />

Set of cases with accessories 3)<br />

DKD <strong>calibration</strong> certificate, instrument + 1 probe<br />

5 temp., u = 0.05 °C up to 200 °C, then 0.1 % of reading<br />

DKD <strong>calibration</strong> certificate, instrument + 2 probes<br />

5 temp., u = 0.05 °C up to 200 °C, then 0.1 % of reading<br />

DKD <strong>calibration</strong> certificate acc. to customer wishes<br />

Option A<br />

Option B<br />

Option C<br />

Option D<br />

Option E<br />

Option F<br />

Option G<br />

Option H<br />

Option I<br />

Option J on<br />

request<br />

300 g<br />

Option A<br />

Option B<br />

Option C<br />

Option D<br />

Option E<br />

(not possible with the Ex version)<br />

(not possible with the Ex version)<br />

Option H<br />

Option I<br />

Option J<br />

on request<br />

3) The set of cases includes a rugged transport case, 9 V battery and rechargeable battery, battery charger, power supply unit, PC adapter cable and SmartGraph software.<br />

4) High-precision version with increased long-term stability due to ceramic wire wound RTD.


Options and Accessories<br />

Immersion probes<br />

Penetration probes<br />

Surface probes<br />

Customer-specified probes on request<br />

ATEX approval EEX iB II B T4 (optional)<br />

Power supply unit<br />

9 V rechargeable battery and battery charger<br />

9 V battery<br />

Rugged transport case<br />

SmartGraph software<br />

PC adapter cable<br />

Other fields of application<br />

This instrument has been primarily designed for tempera-<br />

ture measurement, however, fitted with corresponding<br />

probes, it may also be used for:<br />

humidity measurement using a <strong>com</strong>bined temperature/<br />

humidity probe and for<br />

flow measurement from 0.1 m/s to 40 m/s using a vane<br />

sensor.<br />

The <strong>calibration</strong> and adjustment possibilities described<br />

above also apply to these measurement parameters. In<br />

addition a printer can be directly connected to the<br />

instrument.<br />

10/05/2010<br />

SmartGraph software<br />

This visualisation and administration software has the<br />

following features:<br />

Graphical and tabulated representation of the measured<br />

values<br />

Graphical representation scalable <strong>online</strong>, zoom/unzoom<br />

function<br />

Graphical/tabulated representation of the measured<br />

values in several windows<br />

Data storage on the PC and printing<br />

Administration of probes and their characteristics in a<br />

database<br />

Transfer rate between probe and instrument<br />

Export to other Windows applications<br />

Windows <strong>online</strong> help<br />

Products and Services within our Testing and Calibration Technology Program<br />

DKD <strong>calibration</strong> services for pressure<br />

Repair of <strong>calibration</strong> units of all makes<br />

Portable pressure measuring devices for testing and<br />

<strong>calibration</strong> tasks<br />

Precision pressure measuring units and pressure<br />

controllers<br />

Primary standards for pressure<br />

Testing technology system solutions<br />

Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing.<br />

Modifications may take place and materials specified may be replaced by others without prior notice.<br />

DKD <strong>calibration</strong> services for temperature<br />

Temperature dry well calibrators<br />

Calibration baths and furnaces<br />

Temperature measuring instruments for testing and<br />

<strong>calibration</strong> tasks<br />

Precision thermometers<br />

Primary standards for temperature<br />

Consulting and training<br />

CALIBRATION ONLINE<br />

L’Orée des Mas, Avenue du Golf, 34670 Baillargues<br />

Tel : 04 67 50 62 57 - Fax : 04 67 50 65 97 - email : info@<strong>calibration</strong>-<strong>online</strong>.<strong>com</strong><br />

<strong>www</strong>.<strong>calibration</strong>-<strong>online</strong>.<strong>com</strong><br />

Calibration Online est distributeur exclusif pour la France de :<br />

D.Ellis, DMA, Mensor, Nav-Aids, Preston, Scandura, Wika Calibration line, Nichesensor* et Ralston* (*non exclusif)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!