<strong>www</strong>.<strong>calibration</strong>-<strong>online</strong>.<strong>com</strong><br />
Solutions pour la Calibration<br />
Avionique, Pression, Température<br />
Applications<br />
Calibrations of thermometers<br />
Temperature measurements within the scope of quality<br />
assurance<br />
Measurements in the service and maintenance sector<br />
Long-term monitoring and <strong>online</strong> documentation<br />
Special Features<br />
High accuracy of 0.03 °C with Pt 100<br />
One- and two- channel version available<br />
Connection of various types of probes possible<br />
Optionally with Ex-approval<br />
Description<br />
The universal hand-held thermometer model CTH 6500,<br />
which has been designed for demanding mobile tempera-<br />
ture measurements, features outstanding precision and<br />
flexibility and is extremely easy to use.<br />
Besides Pt 100 resistance thermometers it also processes<br />
the signals of typical thermocouples. Thus it is possible to<br />
measure temperatures ranging from -200 °C to 1760 °C.<br />
Due to its high accuracy of 0.03 °C in the range of -100 °C to<br />
150 °C this thermometer can be used as a reference<br />
measuring instrument in the biotechnological, pharmaceuti-<br />
cal and food industries and is therefore ideally suited for all<br />
maintenance and service tasks.<br />
Low-drift measuring amplifiers ensure that errors of meas-<br />
urement are minimised, and convenient, user-friendly<br />
adjustment functions considerably simplify adjustments and<br />
<strong>calibration</strong>s:<br />
Calibration by code for a fast adaptation of standard<br />
probes via characteristic hex numbers<br />
10/05/2010<br />
Testing and<br />
Calibration Technology<br />
Hand-Held Thermometer<br />
Model CTH 6500<br />
Model CTH 6500-Ex<br />
Hand-Held Thermometer CTH 6500<br />
WIKA Data Sheet CT 55<br />
Physical <strong>calibration</strong> of probe and display at one, two or<br />
three test temperatures<br />
This way it is possible to reduce measuring errors to a<br />
minimum and to ensure a high display accuracy.<br />
Further characteristic features:<br />
Easy to use<br />
Large display with double temperature indication and bar<br />
graph<br />
Min/Max value for the monitoring of the temperature<br />
limits<br />
Mean value function for statistical evaluations<br />
"Fast mode" enabling faster measurements within 4/s<br />
Optional channel can be turned off to give a clearer view<br />
of the displayed data<br />
Recording and display of temperature cycles with the<br />
help of the SmartGraph software<br />
Excellent price/performance ratio
Characteristic features of the Hand-Held Thermometers<br />
CTH 6500<br />
Operating functions<br />
In the setup menu a menu point can be selected and<br />
changed using the up and down (1) keys. Enter (3) and<br />
ESC (2) can be used for confirmation and termination.<br />
Large LCD display<br />
Membrane<br />
keypad<br />
1. Connection port<br />
for 1 st probe<br />
RS 232 connection port<br />
for PC<br />
2. Connection port<br />
for 2 nd probe<br />
10/05/2010<br />
Moveable clip for stand-up<br />
and hanging position of the<br />
instrument<br />
Probe retainer<br />
The intuitive menu is divided into two levels:<br />
Main menu for the selection of the basic functions and<br />
parameter menu for the setting of the parameters.<br />
Main menu of the CTH 6500<br />
Typical temperature probes<br />
Penetration probe<br />
CTP 9895<br />
Immersion probe<br />
CTP 9830<br />
Parameter menu of the CTH 6500<br />
Surface probe<br />
CTP 9865
Specifications CTH 6500 CTH 6500-Ex EEX ib II B T4<br />
Probe types<br />
Inputs<br />
Measuring ranges<br />
Pt 100<br />
Thermocouples<br />
Humidity<br />
Flow<br />
Measurement uncertainties 1)<br />
Pt 100<br />
TC K, J, L, N and T<br />
TC R and S<br />
Humidity<br />
Flow<br />
Resolution<br />
Display Interface<br />
2) Power supply<br />
Operating time<br />
Ambient temperature<br />
Dimensions<br />
Weight<br />
10/05/2010<br />
Pt 100, thermocouples<br />
Humidity, flow<br />
1 or 2<br />
-200 °C to 850 °C<br />
-200 °C to 1760 °C<br />
0 % to 100 %<br />
0 to 40 m/s<br />
0.03 °C from -100 °C to 150 °C<br />
0.05 °C from -200 °C to 200 °C<br />
0.1 % of reading above 200 °C<br />
0.2 °C from 0 °C to 200 °C<br />
0.5 °C from 200 °C to 1000 °C<br />
1 °C above 1000 °C<br />
1 °C + 0.1 % of reading<br />
1.5 % relative humidity<br />
0.5 % FS<br />
0.01 °C up to 200 °C, then 0.1 °C<br />
Two-line LCD display<br />
RS 232<br />
9 V battery or rechargeable battery<br />
approx. 20 h with battery<br />
0 °C to 40 °C<br />
200 mm x 85 mm x 40 mm<br />
300 g<br />
1) The measurement uncertainty is stated for the whole measuring chain after adjustment and <strong>calibration</strong>.<br />
2) The Ex instrument also has an RS 232 interface, which, however, must not be used in potentially explosive atmospheres.<br />
Pt 100<br />
1 or 2<br />
-200 °C to 850 °C<br />
-<br />
-<br />
-<br />
0.03 °C from -100 °C to 150 °C<br />
0.05 °C from -200 °C to 200 °C<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
0.01 °C up to 200 °C then 0.1°C<br />
Two-line LCD display<br />
(RS 232)<br />
9 V battery or rechargeable battery<br />
approx. 20 h with battery<br />
0 °C to 40 °C<br />
200 mm x 85 mm x 40 mm<br />
Accessories/Options CTH 6500 CTH 6500-Ex EEX ib II B T4<br />
Second input<br />
Pt 100 immersion probe CTP 9825<br />
-200 °C to 500 °C, 3 x 300 mm<br />
Pt 100 immersion probe CTP 9830 4)<br />
-200 °C to 500 °C, 3 x 300 mm<br />
Pt 100 penetration probe CTP 9895<br />
-200 °C to 500 °C, 4 x 300 mm<br />
Pt 100 surface probe CTP 9865<br />
-30 °C to 300 °C, 6 x 150 mm<br />
TC K immersion probe CTP 9125<br />
-200 °C to 1100 °C, 3 x 500 mm<br />
Combined temperature/humidity probe CTP 9025<br />
-30 °C to 80 °C / 0 % rel. humidity to 100 % rel. humidity,<br />
20 x 120 mm<br />
Set of cases with accessories 3)<br />
DKD <strong>calibration</strong> certificate, instrument + 1 probe<br />
5 temp., u = 0.05 °C up to 200 °C, then 0.1 % of reading<br />
DKD <strong>calibration</strong> certificate, instrument + 2 probes<br />
5 temp., u = 0.05 °C up to 200 °C, then 0.1 % of reading<br />
DKD <strong>calibration</strong> certificate acc. to customer wishes<br />
Option A<br />
Option B<br />
Option C<br />
Option D<br />
Option E<br />
Option F<br />
Option G<br />
Option H<br />
Option I<br />
Option J on<br />
request<br />
300 g<br />
Option A<br />
Option B<br />
Option C<br />
Option D<br />
Option E<br />
(not possible with the Ex version)<br />
(not possible with the Ex version)<br />
Option H<br />
Option I<br />
Option J<br />
on request<br />
3) The set of cases includes a rugged transport case, 9 V battery and rechargeable battery, battery charger, power supply unit, PC adapter cable and SmartGraph software.<br />
4) High-precision version with increased long-term stability due to ceramic wire wound RTD.
Options and Accessories<br />
Immersion probes<br />
Penetration probes<br />
Surface probes<br />
Customer-specified probes on request<br />
ATEX approval EEX iB II B T4 (optional)<br />
Power supply unit<br />
9 V rechargeable battery and battery charger<br />
9 V battery<br />
Rugged transport case<br />
SmartGraph software<br />
PC adapter cable<br />
Other fields of application<br />
This instrument has been primarily designed for tempera-<br />
ture measurement, however, fitted with corresponding<br />
probes, it may also be used for:<br />
humidity measurement using a <strong>com</strong>bined temperature/<br />
humidity probe and for<br />
flow measurement from 0.1 m/s to 40 m/s using a vane<br />
sensor.<br />
The <strong>calibration</strong> and adjustment possibilities described<br />
above also apply to these measurement parameters. In<br />
addition a printer can be directly connected to the<br />
instrument.<br />
10/05/2010<br />
SmartGraph software<br />
This visualisation and administration software has the<br />
following features:<br />
Graphical and tabulated representation of the measured<br />
values<br />
Graphical representation scalable <strong>online</strong>, zoom/unzoom<br />
function<br />
Graphical/tabulated representation of the measured<br />
values in several windows<br />
Data storage on the PC and printing<br />
Administration of probes and their characteristics in a<br />
database<br />
Transfer rate between probe and instrument<br />
Export to other Windows applications<br />
Windows <strong>online</strong> help<br />
Products and Services within our Testing and Calibration Technology Program<br />
DKD <strong>calibration</strong> services for pressure<br />
Repair of <strong>calibration</strong> units of all makes<br />
Portable pressure measuring devices for testing and<br />
<strong>calibration</strong> tasks<br />
Precision pressure measuring units and pressure<br />
controllers<br />
Primary standards for pressure<br />
Testing technology system solutions<br />
Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing.<br />
Modifications may take place and materials specified may be replaced by others without prior notice.<br />
DKD <strong>calibration</strong> services for temperature<br />
Temperature dry well calibrators<br />
Calibration baths and furnaces<br />
Temperature measuring instruments for testing and<br />
<strong>calibration</strong> tasks<br />
Precision thermometers<br />
Primary standards for temperature<br />
Consulting and training<br />
CALIBRATION ONLINE<br />
L’Orée des Mas, Avenue du Golf, 34670 Baillargues<br />
Tel : 04 67 50 62 57 - Fax : 04 67 50 65 97 - email : info@<strong>calibration</strong>-<strong>online</strong>.<strong>com</strong><br />
<strong>www</strong>.<strong>calibration</strong>-<strong>online</strong>.<strong>com</strong><br />
Calibration Online est distributeur exclusif pour la France de :<br />
D.Ellis, DMA, Mensor, Nav-Aids, Preston, Scandura, Wika Calibration line, Nichesensor* et Ralston* (*non exclusif)