MODENA S <strong>HE</strong>3.5 TroubleshootingDiagnosticsThe boiler is equipped with an advanced self-diagnosis system. In case of a boiler fault, the display will flash togetherwith the fault symbol (detail 11 - fig. 1) indicating the fault code.Certain faults cause permanent boiler shutdowns (marked with the letter “A”): to restore operation, press the RESETbutton (detail 6 - fig. 1) for 1 second or RESET on the optional remote timer control if installed; if the boiler fails to start,it is necessary to firstly eliminate the fault.other faults (indicated with the letter “F”) cause temporary shutdowns that are automatically reset as soon as the valuereturns within the boiler's normal working range.FaultcodeA01A02A03Table. 6 - List of faultsFault Possible cause CureNo gasElectrode faultNo burner ignitionDefective gas valveIncorrect inlet gas pressureSiphon obstructedFlame detected with Electrode defectivethe burner off Main board defectiveFlow temperature sensor not active or correctlylocatedHigh limit protectionNo system circulationCheck the regular gas flow to the boiler and that the air has been purgedfrom the pipesCheck that the electrode is correctly positioned and free of any depositsCheck and change the gas valveCheck inlet gas pressureCheck and if necessary change the siphonCheck the electrode wiringCheck the PCBCheck the correct positioning and operation of the flow sensorCheck pump and radiator valves present in the systemCheck operation of the internal by-passA04 Flue gas fault Fault F07 happened 3 times in the last 24 hours Check the exchangerA05 Fan problem Tachometer signal interrupted for 1 hour or longer Check the wiring and the fanElectrode faultCheck that the electrode is correctly positioned and if necessary change itA06No flame after theignition phase (6times in 4 minutes)Flame unstableIncorrect valve gas OffsetFlue gas circuit obstructedSiphon obstructedCheck the burnerCheck the Offset at the minimum powerCheck if flue gas circuit is freeCheck and if necessary change the siphonA41Flow sensordisconnectedSensor disconnectedCheck the correct positioning and operation of the flow sensorA42 Flow sensor fault Sensor damaged Change the sensorF07F10F11F13F14F15F34High fumetemperatureFlow sensor faultReturn sensor faultExchanger probefaultFlow sensor faultFan problemSupply voltage under170VThe exchanger probe detects and excessivetemperatureSensor damaged or short circuitedSensor damaged or wiring brokenSensor damaged or wiring shortedSensor damaged or wiring brokenSensor damaged or wiring shortedSensor damaged or wiring brokenSensor damaged or short circuitedSensor damaged or wiring brokenTachometer signal interrupted, fan connectionFan damaged, debris in fanElectric supply problemCheck the exchangerCheck the wiring or change the sensorCheck the wiring or change the sensorCheck the wiring or replace the probeCheck the wiring or change the sensorCheck the wiring and the fanCheck the fan, clean debrisCheck the electrical systemF35Irregular mainsfrequencyElectric supply problemCheck the electrical systemF37Incorrect system Pressure too lowFill the systemwater pressure Sensor damagedCheck the sensorF43ExchangerNo system H 2O circulationCheck the circulating pumpprotection activation. Air in the systemVent the systemF52 Flow sensor fault Sensor damaged Change the sensorA61Controller ABM03faultController ABM03 internal errorCheck the earth connection and replace the controller if necessary.No communication Controller not connectedConnect the controller to the gas valveA62 between controllerand gas valveValve damagedReplace the valveA63A64F66Controller ABM03faultController ABM03 internal errorCheck the earth connection and replace the controller if necessary.26 ENcod. 3541C364 - Rev. 00 - 12/2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!