12.07.2015 Views

Pressure Blowers Cast Aluminum (Models CA, CABD) - Aerovent

Pressure Blowers Cast Aluminum (Models CA, CABD) - Aerovent

Pressure Blowers Cast Aluminum (Models CA, CABD) - Aerovent

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Dimensional DataDirect Drive — Arrangement 4 HI<strong>CA</strong>–14 ALSO AVAILABLE WITH 5.50” AND 7.50” INLETS<strong>CA</strong>–15 AND <strong>CA</strong>–18 ALSO AVAILABLE WITH 5.50” AND 9.69” INLETS<strong>CA</strong>HOUSINGDIMENSIONS (IN.)SIZE FRP<strong>CA</strong>-8 56C 13.38<strong>CA</strong>-956C 13.41143-145TC 14.32<strong>CA</strong>-1056C 14.50143-145TC 14.7556C 14.50<strong>CA</strong>-12 143-145TC 14.75182-184TC 16.0856 14.62<strong>CA</strong>-14 143-145T 14.81182-184T 16.19<strong>CA</strong>-15182-184T 16.94213-215T 19.69<strong>CA</strong>-18182-184T 17.06213-215T 19.81NOTES:01. CW SHOWN, CCW SIMILAR BUT OPPOSITE02. SEE R33865A FOR INLET FLANGE AND OPTIONAL OUTLET FLANGE DIMENSIONS.*03. NOMINAL OUTLET DIAMETERHOUSINGSIZEA* BCDIMENSIONS (IN.)HA HC HE HG JA Q<strong>CA</strong>-8 4.00 3.75 4.00 5.75 7.13 5.56 4.88 3.19 4.13<strong>CA</strong>-9 4.00 4.13 5.00 7.44 8.94 7.50 6.63 3.44 5.63<strong>CA</strong>-10 5.00 4.25 6.00 7.88 10.25 9.44 7.81 3.69 6.56<strong>CA</strong>-12 6.00 5.00 7.00 8.88 11.38 9.63 9.44 4.06 7.25<strong>CA</strong>-14 6.00 6.00 7.00 9.81 12.00 10.25 10.25 4.56 8.06<strong>CA</strong>-15 8.00 7.25 8.00 10.81 13.00 11.38 10.81 5.19 7.88<strong>CA</strong>-18 6.00 6.25 8.00 11.44 14.50 12.69 11.38 4.69 10.69R38848<strong>CA</strong>ccessoriesInlet & Outlet FlangeA I.D.HJE DIA.D DIA.C B.C.B O.D.(G) .44 DIA. HOLES(SEE NOTE )SIZEDIMENSIONS (IN.)A B C D E G H J4 4.06 9.00 7.50 3.69 4.56 4.00 1.25 0.345 5.06 11.00 8.50 4.56 5.56 4.00 1.25 0.316 6.06 11.00 9.50 5.50 6.56 4.00 1.38 0.317 7.06 11.00 9.00 6.44 7.69 8.00 1.25 0.348 8.06 13.50 11.75 7.50 8.63 8.00 1.28 0.3110 10.06 16.00 14.25 9.69 10.65 8.00 1.34 0.38NOTE:R33865A Holes will not be drilled unless customer specifies. If drilled perstandard dimensions shown, holes will be on centerline unless otherwisespecified. Custom hole patterns available at additional charge.1. Discharge flanges not available on downblast discharge configurations.Slide Gate DamperA + 2"KDCJH OPENCLOSEDB O.D.FLANGE, FILTER ORGUARD <strong>CA</strong>N BEMOUNTED OVERTHIS O.D.GA I.D.FENOTE:01. Slide Damper Gate not available on downblast or bottom angular down dischargepositions.SIZEDIMENSIONS (IN.)A B C D E4 4.06 3.91 3.25 4.50 2.695 5.06 4.91 3.50 5.50 2.566 6.06 5.91 4.00 5.50 2.697 7.06 6.91 4.50 5.50 2.888 8.06 7.91 5.00 6.75 2.8110 10.06 9.91 6.00 8.00 3.06SIZEDIMENSIONS (IN.)F G H J K4 1.00 1.06 5.63 9.00 7.755 1.13 0.88 6.13 10.50 9.006 1.06 1.00 6.25 11.50 9.507 1.13 1.13 6.25 12.50 10.008 1.00 1.19 7.75 15.00 11.7510 1.31 1.00 9.00 18.50 14.00R3386613 <strong>Aerovent</strong> Bulletin 916

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!