12.07.2015 Views

GEA CAIRplus - CS Klimateknik

GEA CAIRplus - CS Klimateknik

GEA CAIRplus - CS Klimateknik

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installation of Components and Accessories<strong>GEA</strong> <strong>CAIRplus</strong>6 Installation of Components and AccessoriesIn line with the connection of heat exchangers, humidifiers etc., the coilconnection may only be carried out by specialists with the necessaryknowledge of relevant accident prevention regulations and other standardregulations relevant to health and safety in the workplace, based on theirtraining and experience.DAMAGE TO THE UNIT!When mounting <strong>GEA</strong> CAIR units care must be taken to ensure that no loadsare applied to the floor panels. During installation work suitable measuresshould be taken to ensure that any loads are spread across the bottom profiles(e.g. using grid walkways).6.1 Prerequisites• Check the unit for external damage and check whether it has been properlyassembled and anchored.• Check whether anti-vibration and structure-borne sound attenuating matshave been provided. This means that either:– the foundation has been isolated from the unit using rubber plates (forexample) where the unit is installed on level ground and no specialstructure-borne sound isolation requirements exist;– or, in the case of ceiling mounting, commercially available spring elementshave been used;– or, where very special acoustic requirements exist, an acoustics engineerhas been consulted when selecting the most suitable structure-bornesound attenuation method.• Before you start with the coil connection, check the following:– Drain valves must be installed at all low points in the water system toensure that the water circuit can be fully drained in order to carry outmaintenance or repairs.– A water drain with shut-off valve must be installed in order to drain the unit’swater system.– Air vents must be installed at all the high points of the water system ateasily accessible locations.• Ensure that the piping system is flushed through until it is clean by others anda cleaning record compiled.6.2 Installation of air control and air conveying componentsIn order to prevent the transmission of structure-borne sound, a tension-freeconnection between air ducts and the unit must be made using elastic connectorsor structure-borne sound attenuators (also compare „Structure-borne soundattenuation“ on page 26).If you are connecting air ducts to the units via flexible connectors, the installationlength of the connectors must be less than their extended length.38 PR-2009-0096-GB • Subject to modifications • Status 07/2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!