February 2009Cl/SFB (56)www.dimplex.co.uk<strong>Dimplex</strong><strong>heat</strong> <strong>pumps</strong>working with nature’s energyfor environmentally friendly <strong>heat</strong>ing


A name you can trustFor nearly 60 years, <strong>Dimplex</strong> hasbeen making life more comfortable,in more ways, in more places thanany other company. <strong>Dimplex</strong> has longbeen the number one name in electric<strong>heat</strong>ing technology, having establishedan unmatched reputation for quality,reliability and innovation.The <strong>Dimplex</strong> brand is well known in boththe public and private sectors, particularlywith local authorities, housing associationsand major home builders where thebrand has become synonymous witha commitment to excellence andcustomer satisfaction.2introduction


Why choose a <strong>heat</strong> pump?In the context of ever rising energy costsand climate change, every household is inneed of a <strong>heat</strong>ing technology that isfuture-proof, cost-effective and independentof fossil fuels.Using nature’s energyHeat <strong>pumps</strong> make a significantcontribution towards solvingthe problems associated withincreasingly scarce andevermore expensive energyresources – supplying moreenergy than they consumeby tapping into the freelyavailable, inexhaustible solarenergy stored in the earth,the ambient air or water andconverting this for use in a<strong>heat</strong>ing system.In fact up to 75% of theenergy needed by the <strong>heat</strong>ing system is extracted from theenvironment, so the only energy required is electricity neededto drive the <strong>heat</strong> pump compressor.Put another way, for every 1kWh of electricity used to run the<strong>heat</strong> pump, up to 4kW of useful <strong>heat</strong> is provided, giving the<strong>heat</strong> pump an efficiency of up to 400%.A low carbon <strong>heat</strong>ing solutionWhenever fossil fuels such as gas or oil are burnt, carbondioxide is released. CO 2 is the principle contributor to thegreenhouse effect which is leading to long term climate change.However as <strong>heat</strong> <strong>pumps</strong> extract as much as 75% of their <strong>heat</strong>ingenergy from the environment, building carbon emissions for<strong>heat</strong>ing can be reduced by as much as 50% compared with gasfuelled <strong>heat</strong>ing systems.This is an obvious benefit when considering building regulationsPart L compliance, planning obligations requiring minimumcontributions from renewable energy and EcoHome / Code forSustainable Homes ratings.Low running costsLow ownership costsThe considerable contribution from renewable energy sourcesalso helps to provide running cost savings over fossil fuelled<strong>heat</strong>ing systems and arguably more importantly, future proofsthe system against future energy price increases.But fuel costs are only part of the story. Unlike gas and oil basedsystems, <strong>heat</strong> <strong>pumps</strong> require no costly regular maintenanceor annual safety inspections. And because a <strong>heat</strong> pump has areasonable life expectancy of 20 – 25 years, typically twice thatof a boiler, the investment costs can be recovered over a longerperiod meaning the ownership costs over the working life of thesystem are demonstrably lower.Lifetime ownership cost and CO 2 emissions comparisonCO 2 emmissions kg (000’s) 10 20 30 40 50 60 70 80Air source<strong>heat</strong> pumpGround source<strong>heat</strong> pumpCondensingLPGCondensingOil BoilerCondensingGas BoilerCO 2 emmissions (kg)Costs (£)CO 2 emmissions (kg)Costs (£)CO 2 emmissions (kg)Costs (£)CO 2 emmissions (kg)Costs (£)CO 2 emmissions (kg)Costs (£)CO 2 EmissionCapital & Installation CostHeating Distribution SystemFuel Costs +Servicing Maintenance10 Year Replacement CostCosts £ (000’s) 5 10 154Why choose a <strong>heat</strong> pump?20 25 30 35 40Figures compared over a 20 year period for space and water <strong>heat</strong>ing for a typical 3 bed semi detached home (new build)+Fuel costs based on 2007 gas and electricity prices


The global challengeWhat difference can we make?Emerging nations such as China and India aretoday consuming more and more energy tofuel their enormous economic growth, so whatdifference can a tiny island like the UK make?Indeed if the UK became 100% zero carbontomorrow, it would take China less than 3months to replace the UK’s carbon emissions.However, carbon emissions per capita in theUK are one of the highest in the world – in factif every nation had such high emissions perhead of population, global emissions wouldincrease 3-fold.Climate change is the greatest threat facing the planet, with risingtemperatures causing more droughts, floods and storms causing sea levelsto rise.In the last 20 years, use of the Thames Barrier (designed to protect Londonfrom flooding) has risen from once every two years to six times a year.According to the latest figures from Intergovernmental Panel on ClimateChange (IPCC), 11 of the last 12 years rank in the 12 warmest years since1850 and 2003 was the third hottest year on record. The impacts of weatherrelated disasters are also increasing two to three times more rapidly thanimpacts due to earthquakes.Most scientists agree that climate change is largely due to human activity,mainly the increased use of fossil fuels. The main human influence on theglobal climate is likely to be emissions of greenhouse gases such as carbondioxide (CO 2) and methane.So the UK has a responsibility to demonstrateto the developing nations of the world thatit is possible to achieve economic growthwhile reducing its carbon emissions andenvironmental impact.Planning for the futureCurrently we all have the freedom to choosewhether or not to voluntarily install greenertechnologies to reduce our homes orbusinesses carbon footprint. Some expertspredict that greener technologies will becompulsory through legislation in the nearfuture as has the recycling of our rubbish.The sooner you switch the sooner you can startto save money and the planet.The global challenge5


Harnessingnature’s energyOur environment is full of energy, evenat sub-zero temperatures there is plenty ofenergy available.Heat <strong>pumps</strong> use conventional refrigerationtechnology to extract the sun’s energy stored inthe environment and raise it to a temperaturesuitable for <strong>heat</strong>ing purposes.This method even works in the middle ofwinter at temperatures as low as -25ºC.One system for all types of <strong>heat</strong> sources<strong>Dimplex</strong> <strong>heat</strong> <strong>pumps</strong> offer you three different future-proof <strong>heat</strong>sources, outside air, the ground or water.Air Source <strong>heat</strong> <strong>pumps</strong> utilise the outside airas their energy source. Heat <strong>pumps</strong> can evenextract <strong>heat</strong>ing energy from the outside air attemperatures as low as -25˚C.Ground source <strong>heat</strong> <strong>pumps</strong> extract <strong>heat</strong>from the earth all year-round via ground <strong>heat</strong>collectors buried beneath the ground.Water-to-water <strong>heat</strong> <strong>pumps</strong> extract thermalenergy from the ground water. If the supply isreadily available and the quality is sufficient,ground water is the most efficient source of <strong>heat</strong>.6Harnessing nature’s energy


Trusted technologyA <strong>heat</strong> pump <strong>heat</strong>ingsystem consists of 3components: the <strong>heat</strong>source, the <strong>heat</strong> pump itselfand a <strong>heat</strong> distribution andstorage system.Heat <strong>pumps</strong> are able toproduce more energy thanthey consume by using theconventional refrigerationcycle to absorb <strong>heat</strong> fromthe environment and raiseit to a suitable level for<strong>heat</strong>ing.Using nature’s energy efficientlyHeat <strong>pumps</strong> are among the most efficient <strong>heat</strong>ingand hot water systems available today. Approximately75% of the energy needed for <strong>heat</strong>ing comes fromthe environment. This means that for every 1kWh ofelectricity used to power the <strong>heat</strong> pump compressor,between 3 and 4 kWh of <strong>heat</strong>ing energy are produced,giving the <strong>heat</strong> pump an efficiency of 300-400% orhigher.The <strong>heat</strong> pump’s “efficiency” is known as it’s “Coefficientof Performance” (CoP). This is simply a ratio betweenthe proportion of the total energy supplied that can beextracted from the environment and the amount suppliedby electricity to run the <strong>heat</strong> pump compressor. Thehigher the CoP, the more “free” environmental energythe <strong>heat</strong> pump is using!12Sourcefrom Air or Ground 75%SourceNational Grid 25%1234536EvaporatorHeat PumpCondenser46100%75% of the energy is taken from the environment i.e the air orground and transfered to the <strong>heat</strong> pump.25% of the energy is sourced from the national grid in the normalway of supplying your electricity. This is used to operate the <strong>heat</strong>pump but with very low consumptionThe energy from the air or ground is transfered to the refrigerantinside the <strong>heat</strong> <strong>pumps</strong> evaporator. This causes the temperature ofthe refrigerant to rise and change state from liquid to gas.The refrigerant gas is then compressed, using an electrically drivencompressor, reducing its volume but causing its temperature to risesignificantly.A <strong>heat</strong> exchanger (condenser) then extracts the <strong>heat</strong> energy from thehot refrigerant to <strong>heat</strong> water for central <strong>heat</strong>ing, underfloor <strong>heat</strong>ingor domestic hot water.After giving up its <strong>heat</strong> energy the refrigerant turns back into a liquidand is able to absorb energy from the environment, allowing thecycle to begin again.5Built to last241Powerful, quiet, safe and reliable. The “heart” of the<strong>heat</strong> pump is the Copeland scroll compressor, providinghigh levels of efficiency, reliability and low noise operation.13234Always in control. The WPM <strong>heat</strong> pump managermonitors, regulates and controls the entire system toensure optimum performance and efficiency for <strong>heat</strong>ing,domestic hot water and where applicable, cooling.Evaporator. Large surface area plate <strong>heat</strong> exchangersallow for efficient <strong>heat</strong> transfer of energy from theenvironment. They are compact, efficient and reliable.Insulated casing. Sound insulation around the insidesof the <strong>heat</strong> pump casing reduce operating noise to aminimum.Trusted technology7


The natural solution.....with so many applicationsIncreasingly stringent legislation andescalating fuel costs make <strong>heat</strong> <strong>pumps</strong> theideal choice for so many applications, bothdomestic and non domesticSocial HousingWhether for new build or retro-fit, for selfbuilders, commercial housing developmentsor schools; for <strong>heat</strong>ing, cooling or for usewith underfloor <strong>heat</strong>ing systems or radiators,<strong>heat</strong> <strong>pumps</strong> provide the ideal low carbonenergy solution whatever the application.Social Housing• Ideal for stock refurbishment projects as a means to meeting DecentHomes standards and tackling fuel poverty, particularly in off gas-gridareas.• Significant CO 2 emission savings over other fuels, helping compliancewith higher levels of the Code for Sustainable Homes.• Negligible maintenance requirements.• Significant grant funding opportunities available, either throughLow Carbon Buildings Programme Phase 2 or CERT.Housing DevelopmentsHousing DevelopmentsFlats and Apartments• Up to 50% CO 2 savings over fossils fuelled systems helpstowards Building Regulations Part L / Code for SustainableHomes compliance• Heat <strong>pumps</strong> formally accepted as a “Renewable” technology so meetlocal planning authority requirements to incorporate renwable energyin new buildings (Planning Policy Statement 22 / “Merton Rule”)• Will make a significant contribution towards high EPC scores• Highly marketable “Eco” credentials and low end-user running costsfor <strong>heat</strong>ing / hot waterFlats and Apartments• Multiple high output ground or air source units commonly linkedtogether to provide central plant space/water <strong>heat</strong>ing for multioccupancydwellings• Up to 50% CO 2 savings over fossil fuelled systems helps towardsBuilding Regulations Part L / Code for Sustainable Homes compliance• Significant cost reduction over installing individual <strong>heat</strong> <strong>pumps</strong> in eachapartment• Efficiency benefits of communal systems recognised by SAPSelf Builders• 50% lower CO 2 emissions than gas boilers, so help make a significantcontribution towards Building Regulations Part L compliance,particularly with contemporary styled homes with large glazed areas• High renewable energy contribution so helps ease planning consent• Requires electrical infrastructure only, so ideal for off gas-grid areas• Makes a significant contribution to lower home energy bills• Can be used for energy-efficient swimming pool <strong>heat</strong>ing in the summermonths8ApplicationsSelf Builders


Education• Ongoing schools building programmes, such as Building Schoolsfor the Future can benefit from <strong>heat</strong> pump systems that improve theenvironmental footprint and reduce running and operational costs• Able to meet governmental targets for 60% renewable energy in newschools projects• Can be utilised to provide a valuable learning tool for studentsEducation• 50% grant funding for <strong>Dimplex</strong> ground source <strong>heat</strong> <strong>pumps</strong>through Low Carbon Buildings Programme Phase 2Retail and Commerce• Heat <strong>pumps</strong> meet the increasing local authority requirements toincorporate renewable energy within the energy profile of newbuildings (Planning Policy Statement 22 / “Merton Rule”)• Significant CO 2 savings over fossil fuelled systems help towardsbuilding regulations compliance• Many developers investing in “green” buildings with low energy costsin the knowledge that they can attract premium rent/lease values• Ability to provide energy efficient <strong>heat</strong>ing and cooling from a singlesystem optimises capital investmentLeisure and ResidentialRetail and Commerce• Growing take up in the leisure / hotels sector to reduce consumptionand CO 2 emissions, particularly where mains gas is not available• Typical uses include swimming pool <strong>heat</strong>ing, hot water production,space <strong>heat</strong>ing and cooling• Reversible units with <strong>heat</strong> recovery ideal for utilising waste <strong>heat</strong> forswimming pool or water <strong>heat</strong>ing• Multiple air source units commonly linked together to provide centralplant space/water <strong>heat</strong>ing for multi-occupancy dwellings such as carehomesPublic and Community• <strong>Dimplex</strong> <strong>heat</strong> <strong>pumps</strong> are already installed in a wide range of public andcommunity buildings, both new build and refurbished, allowing them tobenefit from lower fuel bills and reduced CO 2 emissionsLeisure and Residential• Typical installations include:• Visitor centres• Village halls• Community centres• Emergency service buildings (fire stations,mountain rescue centres, lifeboat stations)• Libraries• Places of worship• Local government and not for profit organisations are ableto benefit from 50% funding through Low Carbon BuildingsProgramme Phase 2• Match funding available through the Community SustainableEnergy Programme (CSEP)Public and CommunityApplications9


Renewableenergy grantsA number of grant schemes and financialincentives are available to help subsidise thecost of renewable energy installations acrossthe UK and Ireland.UK WideLow Carbon Building Programme (Phase 1)Open to households across the UK (except the ChannelIslands and the Isle of Man), Phase 1 of the Low CarbonBuildings Programme demonstrates how energy efficiencyand microgeneration can work hand in hand to createlow carbon buildings.Grants of £1200 are available to householders for theinstallation of ground source <strong>heat</strong> <strong>pumps</strong> or £900 for theinstallation of air source <strong>heat</strong> <strong>pumps</strong>.For more information visit: www.lowcarbonbuildings.org.ukLow Carbon Buildings Programme (Phase 2)Phase 2 of the DTI Low Carbon Buildings Programmeis managed by the Building Research Establishmentand provides £50 million of capital grant funding forthe installation of various microgeneration technologies– including ground source <strong>heat</strong> <strong>pumps</strong> – by organisationsin the UK public and not-for-profit sectors, includinglocal authorities, housing associations, schools, colleges,community buildings, hospitals and registered charities.The scheme is operating in England, Wales, Scotlandand Northern Ireland and aims to commit the bulk of itsfunding by June 2009.<strong>Dimplex</strong> has been appointed as one of only 3“Framework Suppliers” of ground source <strong>heat</strong> <strong>pumps</strong>under the scheme, meaning <strong>Dimplex</strong> systems are subjectto grants of 50% of their total installation cost.For more information visit:www.lowcarbonbuildingsphase2.org.ukor email lcbp@dimplex.co.ukScotlandScottish Community &Householder Renewables InitiativeThe Scottish Community Householder RenewablesInitiative (SCHRI ) provides grants for properties inScotland. This is funded by the Scottish Executive andmanaged by the Energy Saving Trust.Grants are available for a variety of renewable energytechnologies including ground source and air source <strong>heat</strong><strong>pumps</strong>. Funding for householders is set at 30% of theinstalled cost up to £4,000.For more information visit: www.energysavingtrust.org.uk/schriRepublic of IrelandGreener Homes SchemeThe Greener Homes Scheme provides assistance to homeowners whointend to purchase a new renewable energy <strong>heat</strong>ing system for existinghomes over 1 year old. The scheme is administered by SustainableEnergy Ireland and aims to increase the use of sustainable energytechnologies within Irish homes.The scheme provides grants of €2,500 for ground source <strong>heat</strong> <strong>pumps</strong>(with horizontal collectors) or water source <strong>heat</strong> <strong>pumps</strong>, €3,500 forground source <strong>heat</strong> <strong>pumps</strong> with vertical borehole collectors or €2,000for air source <strong>heat</strong> <strong>pumps</strong>.Renewable Heat Deployment Programme (ReHeat)ReHeat provides assistance for one installation of renewable <strong>heat</strong>ingsystems including ground, air, water source <strong>heat</strong> <strong>pumps</strong> in industrial,commercial, public and community premises in Ireland.Support of up to 30% of eligible costs is available for capitalinvestment projects and 40% of eligible costs is available for feasibilitystudy projects.The programme is administered by Sustainable Energy Ireland.For more information on either of these schemes visit: www.sei.ie/grants orcontacts <strong>Dimplex</strong> (details on back cover).<strong>Dimplex</strong> Renewable Energy Finance<strong>Dimplex</strong> Renewable Energy Finance has been specifically designed tohelp not-for-profit organisations including local authorities, schools andhousing associations overcome the need for initial capital investmentwhen installing <strong>heat</strong> pump systems.The scheme is designed to provide a solution for organisations lookingto implement renewable energy technologies but for whom the initialcapital outlay, even where grants are available, could make goingahead with the project an impossibility, by allowing investment costs tobe repaid over a period of years funded through the savings in energycosts the <strong>heat</strong> pump will provide.Benefits of the scheme include:• Finances match funding for LCBP2 (or other grant schemes)• Can be used in place of grants to cover entire project costs• Project costs covered in full with no up-front capital outlay• Investment costs recovered from energy cost savings on an ongoingbasis• Allows project schedules to be accelerated by removing budgetaryconstraints• Flexible payment schedules and accounting structure based onclient needs10Funding / Grants


InstallersApproved Installer PartnersHeat <strong>pumps</strong> are one of the most efficient andeconomical <strong>heat</strong>ing systems available provided theindividual components of the system – the <strong>heat</strong> source,the <strong>heat</strong> pump itself and the connected <strong>heat</strong>ing system– are properly matched.In order to ensure the highestlevels of quality and to providepeace of mind, <strong>Dimplex</strong> has anestablished network of ApprovedHeat Pump Installer Partners, allaccredited under the ClearSkiesscheme and fully trained andAPPRO EDHeat PumpInstaller Partnerexperienced in the installation, commissioning and aftersales support of <strong>Dimplex</strong> <strong>heat</strong> pump products.Microgeneration Certification SchemeThe Microgeneration Certification Scheme (MCS) is intendedto provide a robust third party certification scheme formicrogeneration products and installers and is designed tounderpin the governments grant scheme, the Low CarbonBuildings Programme. Grants will only be available toapplicants using both products and installers certified underthe Microgeneration Certification Scheme.The scheme evaluates products and installers against robustcriteria for each of the microgeneration technologies,providing greater protection for consumers and ensuringthat the Government’s grant money is spent in an effectivemanner.<strong>Dimplex</strong> recognises the importance of such schemes inhelping to build a UK <strong>heat</strong> pump industry based on qualityand good practice, which will make a substantial contributionto cutting the UK’s dependency on fossil fuels and its carbondioxide emissions.<strong>Dimplex</strong> actively supports the scheme and we encourage all<strong>Dimplex</strong> <strong>heat</strong> pump installers to also become certified, givingour customers assurance as to the quality of our productsand their installation and providing a means of accessinggovernment grants.For more information visit: www.microgenerationcertification.orgInstaller Training<strong>Dimplex</strong> believe that the key to success in the <strong>heat</strong>pump market is through thorough and robust installertraining to ensure installations are provided to a highstandard and maximise the energy efficiency of ourcustomers investment.In addition to an approvedinstaller partner network wealso provide dedicated trainingcourses for new installers,covering installation of ourrange of ground and air source<strong>heat</strong> <strong>pumps</strong>. As the publicinterest in the environment andrenewable energy products inparticular increases, trainingensures our installers are betterequipped to satisfy our customers’requirements.Ground SourceHeat PumpInstallerInstallers / MCS11


Rangeoverview<strong>Dimplex</strong> is setting new standardswith its latest generation of <strong>heat</strong><strong>pumps</strong>. With the widest range of<strong>heat</strong> <strong>pumps</strong> in the UK, no matterwhat your choice of energy source(ground, air or water), there willbe a solution in the <strong>Dimplex</strong> rangeideally suited to your needs.FlexibleOur “integrated” <strong>heat</strong> <strong>pumps</strong> – containingkey hydraulic system components – providespace saving and simple installation, whileour stand alone models can be combinedwith a wide range of fully coordinatedsystem accessories, including buffer tanksand domestic hot water cylinders, to providecomplete flexibility in terms of systemdesign.PerformanceThe <strong>Dimplex</strong> ethos is always toaim for the highest level of systemefficiency, with our <strong>heat</strong> <strong>pumps</strong>designed to minimise energy use– no matter what the temperature oroperating conditions.Quality and ReliabilityGerman engineering from one of theUK’s most respected <strong>heat</strong>ing brands!The international quality labelfor <strong>heat</strong> pump systemsguarantees the highest,environmental, safety andquality standards.AttractiveInnovative technology in a new look.The entire <strong>Dimplex</strong> range, includingbuffer tanks and hot water cylinders,is designed to fully coordinate in anew standardised design.ControlThe comprehensive <strong>Dimplex</strong> <strong>heat</strong>pump manager provides completesystem control over multiple <strong>heat</strong>ingand hot water circuits and, whereneeded, cooling functions. Selfexplanatory display text providessimple operation.12Range overview


Outdoor air source<strong>heat</strong> <strong>pumps</strong>Indoor air source<strong>heat</strong> <strong>pumps</strong>LA MS/LA AS* rangesLI MEK rangeSI MEK range• Outdoor installation• Flow temperature up to 55ºC• Heating capacities: 11 – 40kW• Connection voltages: 230V single phase400V three phaseOptions available:• Heating / hot water• Heating / hot water and active dynamic cooling• Two level output capacity• Flow temperature up to 55ºC, 65ºC (LA PSrange) or 75ºC (LA HS range)• Indoor installation in corners or on walls• Integrated system components and buffer• Flow temperature up to 58ºC• Heating capacity: 8kW• Connection voltage: 230V single phaseOptions available:• Heating / hot water only• Heating / hot water and active dynamiccoolingLAK M/LA MR/LA TR ranges• Outdoor installation• Integrated system components• Flow temperature up to 60ºC• Heating capacities: 6 – 16kW• Connection voltages:230V single phase400V three phaseLI ME/LI TE rangesOptions available:•Heating / hot water only•Heating / hot water and dynamic cooling•Swimming pool (LAS range)• Indoor installation in corners or on walls• Flow temperature up to 58ºC• Heating capacities: 11 – 28kW• Connection voltages: 230V single phase400V three phaseOptions available:•Heating / hot water only•Heating / hot water and active dynamic cooling•Two level output capacity•Flow temperature up to 58°C or75°C (LI TEH range)SI ME/SI TE rangesGround source <strong>heat</strong> <strong>pumps</strong>SI TE range• Indoor installation• Integrated system components• Flow temperature up to 58ºC• Heating capacities: 11 – 16kW• Connection voltage: 230V single phaseOptions available:• Heating / hot water only• Passive cooling via PKS14/25• Indoor installation• Flow temperatures up to 60ºC• Two level output capacity• Heating capacities: 24 – 130kW• Connection voltage: 400V three phaseOptions available:• Heating / hot water only• Heating / hot water and active dynamiccooling with <strong>heat</strong> recovery• Passive cooling• Indoor installation• Flow temperatures up to 58ºC• Heating capacities: 5 – 21kW• Connection voltages:230V single phase400V three phaseOptions available:•Heating / hot water only•Passive cooling•Heating / hot water and activedynamic coolingSI MEH/SI TEH range• Indoor installation• Flow temperatures up to 70ºC• Heating capacities: 6 – 40kW• Connection voltage:230V single phase400V three phaseOptions available:•Heating / hot water only• Passive cooling• Two level output capacityWI ME/WI TE/WI CS rangesHeat Pump accessoriesWater to water<strong>heat</strong> <strong>pumps</strong>• Indoor installation• Flow temperature up to 58ºC• Heating / hot water capacities: 9 – 90kW• Connection voltage:230V single phase400V three phaseOptions available:• Heating / hot water only• Domestic hot water cylinders• Buffer cylinders• Hydraulic system accessories• Ground collector circuit manifolds and accessories• Cooling accessories*Image not applicable to LA 40 AS. Please see page 19 for image.Range overview13


Air source<strong>heat</strong> <strong>pumps</strong>Even cold air is full of energy and<strong>Dimplex</strong> air source <strong>heat</strong> <strong>pumps</strong>use the freely available <strong>heat</strong> inthe ambient air to provide efficient<strong>heat</strong>ing and hot water at airtemperatures as low as -25ºC.Because the source of <strong>heat</strong> –the air – is abundantly availableall around us, air source <strong>heat</strong><strong>pumps</strong> have the advantage of lowinstallation costs and minimal spacerequirements, while relatively mildwinter temperatures in the UKmean excellent levels of efficiencyand performance are achievedthroughout the year.14 Air source <strong>heat</strong> <strong>pumps</strong>Benefits of the outside air as a <strong>heat</strong> source:• Can be utilised all year round between +35ºC and -25ºC.• Always available and inexhaustible source of <strong>heat</strong>.• No requirement for the cost and land area of ground collectors.• Ideal for new build or retro fit applications, especially wherespace is limited.• Can be used for <strong>heat</strong>ing, cooling, domestic hot water andswimming pools.Air source <strong>heat</strong> <strong>pumps</strong> –benefits of the UK climateCompared with central Europe(where air source <strong>heat</strong> <strong>pumps</strong> are alreadyvery popular), the UK has a relativelymoderate winter climate.With average winter temperatures ofaround 5°C, seasonal co-efficients ofperformance comparable with groundsource <strong>heat</strong> <strong>pumps</strong> are achievable, withoutthe additional cost of expensive groundloop systems having to be installed.Average UK temperaturesover 12 month period2824201612840JFM A M J J A S O N Dmaximum temperature (ºC)minimum temperature (ºC)maximum temperature (°C)minimum temperature (°C)2824201612840


Optional outdoor or indoor installationAir source <strong>heat</strong> <strong>pumps</strong> are suitable for either outdoor or indoorinstallation.<strong>Dimplex</strong> outdoor air source <strong>heat</strong> <strong>pumps</strong> are constructed from robust,powder-coated metal casings to provide year round protection againstthe elements. The <strong>heat</strong> pump is connected to the indoor <strong>heat</strong>ing systemsimply by laying two <strong>heat</strong> insulated pipes and the electric connectioncables under the ground.In some instances it may not be desirable for the <strong>heat</strong> pump to beinstalled in the garden. Indoor air source <strong>heat</strong> <strong>pumps</strong> offer a practicalalternative and can be installed for example in a garage, basement orutility room. The <strong>heat</strong> pump is connected to the outside air via air ducts.CASE STUDIESHeat <strong>pumps</strong> in action<strong>Dimplex</strong> <strong>heat</strong> <strong>pumps</strong> have been installed in a wide variety ofapplications – two are featured here, but more are availableon our website.<strong>Dimplex</strong> <strong>heat</strong> <strong>pumps</strong> score forMcCarthy & StoneMcCarthy & Stone, the UK’s largest builder of retirement homes,took the lead in energy savings by installing <strong>Dimplex</strong> <strong>heat</strong>ing<strong>pumps</strong> at a development of 41 apartments in Clevedon,Somerset and achieved level 3 of the Code for SustainableHomes. Three 28kW <strong>Dimplex</strong> air source <strong>heat</strong> <strong>pumps</strong> providea communal system, servicing the entire block, with each flathaving its own metering and separate hot water cylinder.Note: Combined DHW / buffer tank shownAir to water <strong>heat</strong> <strong>pumps</strong> for outdoor installation• The <strong>heat</strong> source is easy to tap.• The weatherproof <strong>heat</strong> pump is installed on a sturdy concretefoundation.• The water pipes and electric cables are securely laid under ground.National Trust customers keep comfywith <strong>Dimplex</strong>A restaurant at Feock, the National Trust tiered garden estatenear Truro in Cornwall is using a <strong>Dimplex</strong> 11kW air source<strong>heat</strong> pump to utilise warm air from the kitchen fridges to keepcustomers warm. The condensers from the back of the fridgeshave been remotely sited alongside the <strong>Dimplex</strong> air source <strong>heat</strong>pump in an insulated outbuilding which means the air to water<strong>heat</strong> pump is given a kick start by the warm air expelled fromthe kitchen fridges.”The <strong>heat</strong> generated by the system is used for under floor <strong>heat</strong>ingin the new Crofters restaurant and there is the additional benefitthat the kitchen is cooler with the refrigerators’ <strong>heat</strong> extractedoutside the building.Air to water <strong>heat</strong> <strong>pumps</strong> for indoor installation• The <strong>heat</strong> source is tapped via air ducts.• Heat pump is installed against an external wall.• The insulated opening is protected by a rain guard.Case studies15


Air source<strong>heat</strong> <strong>pumps</strong>Outdoor installationOur robust outdoor air source <strong>heat</strong> <strong>pumps</strong>are constructed to withstand the best andworst of the British climate, with powdercoatedmetal casings and a stainless steelbase frame. They’re ideal where internalspace is limited and can be installed up to30cm from the building.An air source <strong>heat</strong> pump system is normally designed to deliver 100%of the <strong>heat</strong>ing and hot water demand, with the <strong>heat</strong> pump itselftypically sized to provide at least 95% of the <strong>heat</strong>ing requirement. Tominimise investment costs, it is normal to provide the remaining energydemand from a supplementary <strong>heat</strong> source, most commonly an electricimmersion <strong>heat</strong>er, however in retro-fit applications it is also possible tocombine the <strong>heat</strong> pump with an existing boiler.Single phase devices are available in outputsof 6-16kW providing a range of solutionsfor both domestic and light commercialapplications.16Outdoor Installation


Integrated airsource <strong>heat</strong> <strong>pumps</strong>LAK MThe <strong>Dimplex</strong> LAK10 M air source <strong>heat</strong> pumpprovides extra low installation costs with the helpof fully integrated system components, includingthe <strong>heat</strong>ing system circulation pump, 8 litreexpansion vessel, hydraulic safety devices and athree capacity supplementary <strong>heat</strong>ing element(2, 4 or 6kW).LAK 10 M is designed to provide both <strong>heat</strong>ingand domestic hot water.Range featuresLAK 10 M• Nominal <strong>heat</strong>ing capacity 10kW.• Variable <strong>heat</strong>ing water flow temperature from 35°Cto 58°C.• Integrated system components, including immersion<strong>heat</strong>er and circulating pump.• Suitable for use with under floor <strong>heat</strong>ing or radiatorsystems and to provide domestic hot water.• Electronic soft start reduced starting current loads.Free standing airsource <strong>heat</strong> <strong>pumps</strong>ModelLAK 10 MConnection Voltage (V) 230Maximum flow temp (°C) 58Heat output (kW) A7/W35 10.2CoP A7/W35 4.1Please see page 44 for full technical specifications.LA MS<strong>Dimplex</strong> LA MS air source <strong>heat</strong> <strong>pumps</strong> provideexcellent levels of <strong>heat</strong>ing and hot waterperformance at temperatures as low as 20°C.The range incorporates air deflector hoods tominimise sound transmissions and an autoadaptivedefrost cycle to minimise energyconsumption.Range features• 2 models with nominal <strong>heat</strong>ing capacities from11 – 16kW single phase.• Corrosion resistant stainless steel inner frameand powder coated outer housing.• Variable <strong>heat</strong>ing water flow temperature from35°C – 55°C with weather compensation.• Suitable for use with underfloor <strong>heat</strong>ing or radiatorsystems and to provide domestic hot water.• Extensive sound insulation minimises noiseemissions.• Energy optimised auto adaptive defrost cycle.• Electronic soft start reduces starting current loads.LA 16 MSModel LA 11 MS LA 16 MSConnection Voltage (V) 230 230Maximum flow temp (°C) 55 55Heat output (kW) A7/W351 Compressor 10.9 15.42 Compressors - -CoP A7/W351 Compressor 4.1 3.7Please see page 44 for full technical specifications.LAK M / LA MS17


Air source<strong>heat</strong> <strong>pumps</strong>High output air source <strong>heat</strong><strong>pumps</strong> for outdoor installation<strong>Dimplex</strong> high output air source <strong>heat</strong> <strong>pumps</strong>expand the scope of the applications for highefficiency <strong>heat</strong>ing solutions with a range ofincreased output models ranging from20-40kW.Optimised twin compressor operation allowsbuildings with high <strong>heat</strong> consumption tobe catered for, such as offices, schools,hotels or retail outlets. High output <strong>heat</strong><strong>pumps</strong> are also ideal for multiple occupancybuildings such as flats and apartments wherecentralised <strong>heat</strong> pump systems are able toprovide a building-wide <strong>heat</strong>ing solution.Parallel operation for higher total capacityMultiple <strong>Dimplex</strong> <strong>heat</strong> <strong>pumps</strong> can be connected together inparallel to provide a highly cost effective solution where very highcapabilities are required.The WPM <strong>heat</strong> pump manager controls and optimisesperformance of the system.18Outdoor Installation


High output airsource <strong>heat</strong> <strong>pumps</strong>LA ASThe <strong>Dimplex</strong> LA AS range of high output 3phase air source <strong>heat</strong> <strong>pumps</strong> provide a flexiblerange of solutions for higher capacity <strong>heat</strong>ingsystems.All models utilise a wall mounted WPM 2007<strong>heat</strong> pump manager, allowing independentcontrol over multiple <strong>heat</strong>ing circuits at differingflow temperatures.Twin compressor operation enables thesemodels to flexibly and efficiently adapt tofluctuating <strong>heat</strong> demand by automaticallyswitching between single and dual compressormodes depending on the outside temperatureand <strong>heat</strong> demand of the building.Range featuresLA 20-28 AS• Range of 4 models with nominal <strong>heat</strong>ingcapacities from 20-40kW.• Variable <strong>heat</strong>ing water flow temperatures from35°C-55°C with weather compensation.• Intelligent switching between single and dualcompressor modes, maximising efficiency andcompressor duty cycle.• WPM 2007 <strong>heat</strong> pump manager.• Suitable for use with under floor <strong>heat</strong>ing, radiatoror fan coil systems and to provide hot water.• Three phase electrical connection, with electronicsoft start to reduce start current loads.• Optional flexible expansion for bivalent orbivalent-renewable operating mode and fordistributed systems with unmixed and mixed<strong>heat</strong>ing circuits.• LA 40 AS modes incorporates horizontal air flowcircuit, minimising installation space requirements.LA 40 ASModel LA 20 AS LA 24 AS LA 28 AS LA 40 ASConnection Voltage (V) 400 400 400 400Maximum flow Temperature (°C) 55 55 55 55Heat Output A7/W35 (kW)1 compressor 9.8 13.1 14.2 20.22 compressors 16.6 24.8 25.8 36.3CoP A7/W351 compressor 3.2 3.4 3.1 4.72 compressors 3.1 3.6 3.4 4.5Please see page 44 for full technical specifications.LA AS19


Air source<strong>heat</strong> <strong>pumps</strong>Indoor installationIndoor air source <strong>heat</strong> <strong>pumps</strong> can be installedin a utility room, garage or basement and aredesigned with low noise emissions in mind.Single phase models are available in outputsof 8-11kW, with outputs up to 28kW availablefor 3 phase connection, providing solutionsfor both domestic and light commercialapplications alike.The 8kW LI 8 MEK ‘integrated’ <strong>heat</strong> pump is designed to fit neatlyinto the corner of room with no need for additional ducting. Manyof the hydraulic system components are built in providing simple andconvenient installation.Alternatively, the LI ME and LI TE ranges provide flexible system design,allowing buffer tanks, domestic hot water cylinders and hydrauliccomponents to be specified and installed as and when required.20Indoor Installation


Integrated airsource <strong>heat</strong> pumpLI MEKThe LI 8 MEK saves valuable space and iseasy to install, with the WPM2007 <strong>heat</strong> pumpmanager and key system components fullyintegrated into one compact unit.Range featuresTEMP SHOT• Nominal <strong>heat</strong>ing capacity 8kW.• Variable <strong>heat</strong>ing water flow temperatures from35˚C – 58˚C with weather compensation.• Integrated system components, including 50L buffertank, 2kW immersion <strong>heat</strong>er, circulating pump andexpansion vessel.• WPM2007 <strong>heat</strong> pump manager with removablecontrol panel.• Designed for ‘through wall’ installation in the cornerof a room against two outside walls – no additionalducts needed.• Suitable for use with underfloor <strong>heat</strong>ing or radiatorsystems and to provide domestic hot water.• Energy optimised auto adaptive defrost cycle.• Electronic soft start reduces starting current loads.LI 8 MEKUniversal design airsource <strong>heat</strong> <strong>pumps</strong>LI ME & LI TELI indoor air source <strong>heat</strong> <strong>pumps</strong> are availablein outputs from 11-28kW and incorporate lownoise fans to minimise sound transmission.Models with twin compressors (20kW and over)incorporate intelligent load switching to maximisecompressor life.Range features• 5 models with nominal <strong>heat</strong>ing capacities of 11kWsingle phase and 16 – 28kW three phase.• 20kW and above models fitted with twincompressors for higher capacity output and twoperformance capacities.• Variable <strong>heat</strong>ing water flow temperatures from35ºC – 58ºC with weather compensation.• WPM2007 <strong>heat</strong> pump manager with removablecontrol panel for installation in a preferred location.• Suitable for use with underfloor <strong>heat</strong>ing or radiatorsystems and to provide domestic hot water.• Energy optimised, auto adaptive defrost cycle.• Complementary built-under buffer tank for spacesaving.• Air ducting kits provided as accessories.• Electronic soft start reduces starting current loads.LI 11 MEModelLI 8 MEK LI 11 ME LI 16 TE LI 20 TE LI 24 TE LI 28 TEConnection Voltage (V) 230 230 400 400 400 400Maximum flow temp (°C) 58 58 58 58 58 58Heat output (kW) A7/W351 Compressor 9.2 10.9 15.1 10.4 12.6 13.92 Compressors - - - 17.0 24.2 25.1CoP A7/W351 Compressor 3.8 3.9 3.6 3.5 3.3 3.12 Compressors - - - 3.4 3.4 3.3Please see page 46 for full technical specifications.LI MEK / LI ME / LI TE 21


Air source<strong>heat</strong> <strong>pumps</strong>Medium and high temperatureair source <strong>heat</strong> <strong>pumps</strong>Improving a buildings thermal insulationcan often be enough to allow the <strong>heat</strong>ingsystem to be operated at low temperatures.However higher water flow temperatures aresometimes needed where high volumes of hotwater are required at temperatures of 60°C orhigher, or where the <strong>heat</strong> pump is intendedfor use in older buildings with existingradiator systems.LA PS medium temperature models utilise the environmentallysensitive R290 refrigerant and are available for outdoor installationonly, while high temperature models are available for installationeither indoors or outdoors.The <strong>Dimplex</strong> ranges of medium and hightemperature air source <strong>heat</strong> <strong>pumps</strong> providejust this facility, providing water outputtemperatures of 65°C and 75°C respectively.22Air source <strong>heat</strong> <strong>pumps</strong>


Mediumtemperature airsource <strong>heat</strong> <strong>pumps</strong>LA PSThe LA PS medium temperature <strong>heat</strong> <strong>pumps</strong> areavailable for outdoor installation and providevariable water flow temperatures of up to 65°C.Range features• 5 models with nominal <strong>heat</strong>ing capacities from9 – 26kW.• Variable <strong>heat</strong>ing water flow temperatures from35ºC – 65ºC with weather compensation.• Higher output models (17kW and above) fitted withtwin compressors for high capacity output and twoperformance capacities.• Intelligent switching between single and dualcompressor modes, maximising efficiency andcompressor duty cycle.• For outdoor installation only.• Utilises environmentally sensitive R290 refrigerant.• WPM2006 <strong>heat</strong> pump manager.• Electronic soft start reduces starting current loads.LA 9 PSLA 17 PSModel LA 9 PS LA 11 PS LA 17 PS LA 22 PS LA 26 PSConnection Voltage (V) 400 400 400 400 400Maximum flow temp (°C) 65 65 65 65 65Heat output A7/W35(kW)1 Compressor 8.5 11.5 9.6 12.0 13.32 Compressors - - 16.6 21.1 22.9CoP A7/W351 Compressor 3.6 3.8 3.4 3.6 3.52 Compressors - - 3.4 3.5 3.5Please see page 46 for full technical specifications.High temperatureair source <strong>heat</strong><strong>pumps</strong>LA HS & LI TEH<strong>Dimplex</strong> high temperature <strong>heat</strong> <strong>pumps</strong> areavailable for either outdoor or indoor installationand provide variable water flow temperatures ofup to 75°C.Range features• Nominal <strong>heat</strong>ing capacities of 22kW and 26kW inboth outdoor and indoor installation options.Variable <strong>heat</strong>ing water flow temperatures from35ºC – 75ºC with weather compensation.• Twin compressors for high temperature output.• Intelligent switching between single and dualcompressor modes, maximising efficiency andcompressor duty cycle.• LI HS models fitted with integrated WPM2007 <strong>heat</strong>pump manager with removable control panel.• LA HS models supplied with WPM2006 <strong>heat</strong> pumpmanager.• Electronic soft start reduces starting current loads.LI 26 TEHLA 22 HSModel LI 22 TEH LI 26 TEH LA 22 HS LA 26 HSConnection Voltage (V) 400 400 400 400Maximum flow temp (°C) 75 75 75 75Heat output A7/W35(kW) 15.2 19.5 15.2 19.5CoP A7/W35 3.2 3.6 3.2 3.6Please see pages 46 for full technical specifications.LA PS / LA HS / LI HS23


Groundsource <strong>heat</strong><strong>pumps</strong>Drawing as much as 75% of theenergy needed by the <strong>heat</strong>ingsystem from freely available,inexhaustible solar energy storedin the ground, <strong>Dimplex</strong> groundsource <strong>heat</strong> <strong>pumps</strong> are available inan extensive range of models typesand capacities suitable for eitherdomestic or commercial applications.Due to highly stable temperaturesbelow the earth’s surface, groundsource <strong>heat</strong> <strong>pumps</strong> provide highlevels of efficiency for space andwater <strong>heat</strong>ing all year round.Benefits of the ground as a <strong>heat</strong> source• Consistent temperatures below ground throughout the year provides a highCo-efficient of Performance.• Can be used for <strong>heat</strong>ing, domestic hot water and swimming pools.• Borehole systems can be used for either passive or active cooling (see page 36).At just 1m below the surface, theearth provides a stable source of<strong>heat</strong> throughout the year.At depths of 15m or more, theearth provides a constant 10°Ctemperature.0 5Depth5m10m15 m20 mSurface temperature1015 20°CFebruary May November August24Ground source <strong>heat</strong> <strong>pumps</strong>


Heat from the groundThe earth stores an enormous amount of solar energy from both solarradiation and rainfall. To extract this energy, ground collectors consistingof flexible poly ethylene pipes are buried in the earth, either horizontally orvertically. A mixture of water and anti-freeze is then circulated through thepipe loops, attracting the <strong>heat</strong> energy and transferring it to the <strong>heat</strong> pump.CASE STUDIESHeat <strong>pumps</strong> in action<strong>Dimplex</strong> <strong>heat</strong> <strong>pumps</strong> have been installed in a wide variety ofapplications – two are featured here, but more are availableon our website.Housing Association bungalowsconvert to <strong>Dimplex</strong>Stafford & Rural housing association has fitted <strong>Dimplex</strong> groundsource <strong>heat</strong> <strong>pumps</strong> into a refurbishment project of ninewarden-linked bungalows at Synnerton, Staffordshire, with fiveof the properties taking part in a year-long survey by the EST tomonitor <strong>heat</strong> <strong>pumps</strong> in real-life installations.One of the key considerations when replacing the systemwas fuel poverty as economic <strong>heat</strong>ing was very importantto its tenants. The housing association was also looking forsomething that was future-proof, cost effective with no costlybills or annual inspections. Three suppliers were consideredby an assessment panel which included 3 tenants with <strong>Dimplex</strong>selected because of the overall package they could supply.Horizontal ground collectorsIf a large enough land area is available, horizontal ground collectorsprovide an effective method of extracting <strong>heat</strong> from the ground.The pipework is buried at a depth of approximately 1.2m and spaced0.75m apart. The land area required is dependent on both thecapacity of the <strong>heat</strong> pump and <strong>heat</strong> conductance of the soil type inwhich the pipes are buried.As a space saving alternative to horizontal collectors, slinkies -consisting of coiled pipes buried in a trench – can be used.Top Marks for<strong>Dimplex</strong> inLondon schoolEaling council hasinstalled <strong>Dimplex</strong>ground source <strong>heat</strong><strong>pumps</strong> at three schoolsand is already planninga fourth!A <strong>Dimplex</strong> SI 40 TEH high temperature ground source <strong>heat</strong>pump was initially installed at Grange Primary School, alarger than average school with 500 pupils, with 15 boreholesrequired in a restricted area which subsequently became partof the playground.Vertical boreholesIf land space is limited the ground collectors can be installed verticallyin a borehole, drilled up to 100m deep in the ground.Multiple boreholes are commonly used in large installations where veryhigh levels of <strong>heat</strong> extraction are required.Following the success at Grange Primary, a <strong>Dimplex</strong> SI 37 TE<strong>heat</strong> pump has been installed at Mandeville School, Northolt,a co-educational day school for pupils aged 2-12 and aSI 24 TE has been installed at Ellen Wilkinson School for Girlsin Acton, with 1400 students aged 11-18.Case studies25


Ground source<strong>heat</strong> <strong>pumps</strong>Available in a wide range of sizes andconfigurations, <strong>Dimplex</strong> ground source <strong>heat</strong><strong>pumps</strong> provide a sustainable <strong>heat</strong>ing solutionfor virtually any scenario.Flexible system optionsThe <strong>Dimplex</strong> ground source range, including buffer tanks and hot water cylindersare designed to fully co-ordinate and provide a range of flexible system options:As well as being perfectly suitable for usewith either radiators or underfloor <strong>heat</strong>ingsystems, <strong>Dimplex</strong> ground source <strong>heat</strong> <strong>pumps</strong>are able to provide domestic hot water.12Single phase models are available in outputsfrom 5-16kW making them ideal for bothdomestic and light non domestic applicationsalike, while the option of either stand aloneor fully integrated formats provides maximumflexibility to meet the needs of virtually anyscenario.26Ground source <strong>heat</strong> <strong>pumps</strong>1234513 4 4SI ME ground source <strong>heat</strong> pumpSI MEK integrated ground source <strong>heat</strong> pumpWWSP229EUK 200L domestic hot water cylinderPSP100E 100L buffer cylinderWWSP442EUK 400L domestic hot water cylinder5


Ground source<strong>heat</strong> <strong>pumps</strong>SI METhe popular range of SI ME ground source<strong>heat</strong> <strong>pumps</strong> provide flexible system designmaking them ideal for domestic or lightcommercial applications.Where space saving is required the SI MErange can be combined with a 200L domestichot water cylinder, which fits neatly below the<strong>heat</strong> pump unit.Range features• 5 models with nominal <strong>heat</strong>ing capacities from5 – 14kW, single phase.• Variable <strong>heat</strong>ing water flow temperatures from35°C – 58°C with weather compensation.• WPM2007 <strong>heat</strong> pump manager with removablecontrol panel.• Electronic soft start reduces starting current loads.• Suitable for use with underfloor <strong>heat</strong>ing or radiatorsystems and to provide domestic hot water.• Complementary built under 200L domestic hotwater cylinder for space saving.SI 5 MEModel SI 5 ME SI 7 ME SI 9 ME SI 11 ME SI 14 MEConnection Voltage (V) 230 230 230 230 230Maximum flow temp (°C) 58 58 58 58 58Heat output B0/W35 (kW) 4.9 6.3 8.9 10.8 14.8CoP B0/W35 3.8 3.7 3.8 3.9 3.9Please see page 48 for full technical specifications.Integrated groundsource <strong>heat</strong> <strong>pumps</strong>SI MEKThe SI MEK range of fully integrated groundsource <strong>heat</strong> <strong>pumps</strong> provide easy installation andminimises space requirements, with the <strong>heat</strong>pump manager and key system components allfully integrated into one compact unit.A complementary 100L buffer tank and 400Ldomestic hot water cylinder are also available tocomplete the system.Range features• Available with nominal <strong>heat</strong>ing capacities of11 and 16kW, single phase.• Integrated system components, includingcirculating <strong>pumps</strong>, expansion vessels and safetyassemblies for both the <strong>heat</strong>ing and groundcollector circuits.• WPM2007 <strong>heat</strong> pump manager with removablecontrol panel.• Variable <strong>heat</strong>ing water flow temperatures from35ºC – 55ºC with weather compensation.• Suitable for use with underfloor <strong>heat</strong>ing or radiatorsystems and to provide domestic hot water.• Matching built-under buffer tank for space savingand 400L domestic hot water cylinder.SI 16 MEKModel SI 11 MEK SI 16 MEKConnection Voltage (V) 230 230Maximum flow temp (°C) 55 55Heat output B0/W35 (kW) 11.8 15.8CoP B0/W35 4.4 4.2Please see page 50 for full technical specifications.SI ME / SI MEK27


Ground source<strong>heat</strong> <strong>pumps</strong>High temperature groundsource <strong>heat</strong> <strong>pumps</strong><strong>Dimplex</strong> high temperature ground source<strong>heat</strong> <strong>pumps</strong> have the ability to provide highwater flow temperatures up to 70°C.This provides the ability to providethe dwellings full domestic hot waterrequirements with no need for supplementaryelectric <strong>heat</strong>ing.The Co-efficient of Performance for <strong>heat</strong>ingradiators at 50°C has also improved overstandard models, making them ideally suitedto existing as well as new properties.Single phase models are available in outputsfrom 6-11kW, with the option of either standaloneor fully integrated formats to providemaximum flexibility to meet the needs of awide range of applications.Flexible system optionsThe <strong>Dimplex</strong> ground source range, including buffer tanks and hot water cylindersare designed to fully co-ordinate and provide a range of flexible system options:123451SI MEH ground source <strong>heat</strong> pumpSI MEKH integrated ground source <strong>heat</strong> pumpWWSP229EUK 200L domestic hot water cylinderPSP100E 100L buffer cylinderWWSP442EUK 400L domestic hot water cylinder13 4 42528Ground source <strong>heat</strong> <strong>pumps</strong>


High temperatureground source<strong>heat</strong> <strong>pumps</strong>SI MEHThe SI MEH range provides flow temperaturesup to 70°C enabling 100% of a homes <strong>heat</strong>ingand hot water to be provided without the needfor supplementary <strong>heat</strong>ing.Range features• 3 models with nominal <strong>heat</strong>ing capabilities from6-11kW.• Variable <strong>heat</strong>ing water flow temperatures from35°C-70°C with weather compensation.• WPM 2007 <strong>heat</strong> pump manager with removablecontrol panel.• Electronic soft start control reduces starting currentloads.• Suitable for use with under floor <strong>heat</strong>ing or radiatorsystems.• Provides domestic hot water to 60°C with no needfor supplementary <strong>heat</strong>ing.High temperature,integrated groundsource <strong>heat</strong> <strong>pumps</strong>SI MEHModel SI 6 MEH SI 9 MEH SI 11 MEHConnection Voltage (V) 230 230 230Maximum flow temp (°C) 70 70 70Heat output B0/W35 (kW) 6 8.9 10.7CoP B0/W35 4.1 4.0 4.5Please see page 48 for full technical specifications.SI MEKHThe SI MEKH range of fully integrated groundsource <strong>heat</strong> <strong>pumps</strong> provides easy installationand minimises space requirements, with the <strong>heat</strong>pump manager and key system components allfully integrated into one compact unitA complimentary 100L buffer tank and 400Ldomestic hot water cylinder are also available tocomplete the system.Range features• Available with nominal <strong>heat</strong>ing capacity of 9kW.• Integrated system components, including circulating<strong>pumps</strong>, expansion vessels and safety assembliesSI MEKHfor both the <strong>heat</strong>ing and ground circuits.• WPM 2007 <strong>heat</strong> pump manager with removablecontrol panel.• Variable <strong>heat</strong>ing water flow temperatures from35°C-70°C with weather compensation.• Suitable for use with under floor <strong>heat</strong>ing orradiator systems.• Provides domestic hot water to 60°C with no needfor supplementary <strong>heat</strong>ing.• Matching built-under buffet tank for space savingand tool domestic hot water cylinder.ModelSI 9 MEKHConnection Voltage (V) 230Maximum flow temp (°C) 70Heat output B0/W35 (kW) 9.4CoP B0/W35 4.4Please see pages 50 for full technical specifications.SI MEH / SI MEKH29


Ground source<strong>heat</strong> <strong>pumps</strong>High output ground source<strong>heat</strong> <strong>pumps</strong><strong>Dimplex</strong> high output ground source <strong>heat</strong><strong>pumps</strong> expand the scope of applications forhigh efficiency <strong>heat</strong>ing solutions with a rangeof increased output models ranging from17 – 130kW.Optimised twin compressor operation allowsbuildings with high <strong>heat</strong> consumption tobe catered for, in the shape of either nondomesticapplications such as offices orschools. High output <strong>heat</strong> <strong>pumps</strong> are also idealfor multiple occupancy buildings such as flatsand apartments where centralised <strong>heat</strong> <strong>pumps</strong>ystems are able to provide a building wide<strong>heat</strong>ing solution.Flexible system optionsSI 24 TE – SI 37 TE <strong>heat</strong> <strong>pumps</strong> are designed to co-ordinate with theWWSP442EUK hot water cylinder.1 230Ground source <strong>heat</strong> <strong>pumps</strong>12SI 24-37 TE ground source <strong>heat</strong> pumpWWSP442EUK 400L hot water cylinder


High output groundsource <strong>heat</strong> <strong>pumps</strong>SI TEThe <strong>Dimplex</strong> SI TE range of high output3 phase ground source <strong>heat</strong> <strong>pumps</strong> provide aflexible range of solutions for higher capacity<strong>heat</strong>ing systems.All models utilise the WPM2007 <strong>heat</strong> pumpmanager, allowing independent control overmultiple <strong>heat</strong>ing circuits at differing flowtemperatures.Models with outputs of 24kW and aboveincorporate twin compressors, enabling them toflexibly and efficiently adapt to fluctuating <strong>heat</strong>demand by automatically switching betweensingle and dual compressor modes dependingon the outside temperature and <strong>heat</strong> demand ofthe building.SI 21 TESI 17 TERange features• Range of 9 models with nominal <strong>heat</strong>ingcapacities from 17 – 130kW.• Variable <strong>heat</strong>ing water flow temperatures from35˚C – 60˚C with weather compensation.• Twin compressors on outputs of 24kW and overfor higher capacity output.• Intelligent switching between single and dualcompressor modes, maximising efficiency andcompressor duty cycle.• WPM2007 <strong>heat</strong> pump manager with removablecontrol panel.• Suitable for use with underfloor <strong>heat</strong>ing or radiatorsystems and to provide domestic hot water.• Three phase electrical connection, with electronicsoft start to reduce start current loads.• Able to use ground water as a <strong>heat</strong> source withthe addition of an intermediate <strong>heat</strong> exchanger.• Matching 400 litre domestic hot water cylinder.SI 50 – 130 TESI 24 – 37 TEModel SI 17 TE SI 21 TE SI 24 TE SI 30 TE SI 37 TE SI 50 TE SI 75 TE SI 100 TE SI 130 TEConnection Voltage (V) 400 400 400 400 400 400 400 400 400Maximum flow temp (°C) 58 58 60 60 60 60 60 60 60Heat output B0/W35(kW) - - - - - - - - -1 Compressor 16.9 20.8 12.7 14.4 18.3 23.0 37.6 48.4 63.32 Compressors - - 23.7 31.2 35.4 46.7 75.2 96.3 125.8CoP B0/W351 Compressor 4.4 4.1 4.3 4.2 4.5 4.4 4.3 4.6 4.22 Compressors - - 4.1 4.6 4.3 4.5 4.4 4.6 4.3Please see pages 50-54 for full technical specifications.SI TE31


Ground source<strong>heat</strong> <strong>pumps</strong>High output, high temperatureground source <strong>heat</strong> <strong>pumps</strong><strong>Dimplex</strong> high temperature ground source<strong>heat</strong> <strong>pumps</strong> have the ability to provide highwater flow temperatures of up to 70°C.Flexible system optionsSI 20 TEH is designed to co-ordinate with the WWSP442EUK hot water cylinder.This makes them ideal for applications wherehigh volumes of stored hot water are requiredat temperatures of 60°C or higher, or wherethe <strong>heat</strong> pump is required to be connectedto a high temperature <strong>heat</strong>ing system usingradiators.Optimised twin compressor operation allowsthe SI TEH range to be used in buildingswith high <strong>heat</strong> consumption, for examplecommercial applications, schools or forcentralised <strong>heat</strong> production in multipleoccupancy residential buildings such as flats.1 232Ground source <strong>heat</strong> <strong>pumps</strong>12SI 20 TEH ground source <strong>heat</strong> pumpWWSP442EUK 400L hot water cylinder


High temperatureground source<strong>heat</strong> <strong>pumps</strong>SI TEHThe <strong>Dimplex</strong> SI TEH range of high temperatureground source <strong>heat</strong> <strong>pumps</strong> provide variablewater flow temperatures up to 70°C, providinga solution for buildings with high temperature<strong>heat</strong>ing systems (radiators) or where hightemperature hot water storage is required.Available in 20kW and 40kW options, bothmodels utilise the WPM2007 <strong>heat</strong> pumpmanager, allowing independent control overmultiple <strong>heat</strong>ing circuits at differing flowtemperatures.Both models incorporate twin compressors,enabling them to flexibly and efficiently adaptto fluctuating <strong>heat</strong> demand by automaticallyswitching between single and dual compressormodes depending on the outside temperatureand <strong>heat</strong> demand of the building.SI 20 TEHRange features• Nominal <strong>heat</strong>ing capacities of 20kW and 40kW.• Variable <strong>heat</strong>ing water flow temperatures from35°C – 70°C with weather compensation.• Twin compressors for higher capacity output.• Intelligent switching between single and dualcompressor modes, maximising efficiency andcompressor duty cycle.• WPM2007 <strong>heat</strong> pump manager with removablecontrol panel.• Suitable for use with underfloor <strong>heat</strong>ing or radiatorsystems and to provide domestic hot water atstored water temperatures of up to to 60°C.• Three phase electrical connection, with electronicsoft start to reduce start current loads.• Able to use ground water as a <strong>heat</strong> source withthe addition of an intermediate <strong>heat</strong> exchanger.• Matching 400 litre domestic hot water cylinder.SI 40 TEHModel SI 20 TEH SI 40 TEHConnection Voltage (V) 400 400Maximum flow temp (°C) 70 70Heat output B0/W35(kW)1 Compressor 11.5 17.42 Compressors 21.4 34.2CoP B0/W351 Compressor 4.6 4.12 Compressors 4.4 4.1Please see page 52 for full technical specifications.SI TEH33


Water towater <strong>heat</strong><strong>pumps</strong>Water to water <strong>heat</strong> <strong>pumps</strong> workin a similar way to ground sourcesystems, with the exception that theyuse “open loop” collectors, whereunderground water is circulatedthrough the pipes.The <strong>Dimplex</strong> range is available inan extensive range of model typesand capacities suitable for eitherdomestic or commercial applications.High year round water temperaturesallow water to water <strong>heat</strong> <strong>pumps</strong> toprovide very high levels of efficiencywith CoP’s of 5 or over achievable.Underground water stores an enormous amount of solar energy which canbe extracted at very high levels of energy efficiency by circulating it directlythrough the <strong>heat</strong> pump evaporator.Ground water as a <strong>heat</strong> source34Water to water <strong>heat</strong> <strong>pumps</strong>• Year round availability at temperatures of 7-12ºC.• Can be used for <strong>heat</strong>ing, domestic hot water and swimming pools.• Requires environment agency consent to extract and discharge water from/tothe water course.


Water to water<strong>heat</strong> <strong>pumps</strong>WI ME & WI TE<strong>Dimplex</strong> WI ME and WI TE water to water<strong>heat</strong> <strong>pumps</strong> provide flexible system designin <strong>heat</strong>ing outputs from 9 – 27kW, makingthem ideal for domestic or light commercialapplications.Stainless steel coil <strong>heat</strong> exchangers providehigh levels of corrosion resistance, preventingthe need for water analysis prior to installation.Range features• 5 models with nominal <strong>heat</strong>ing capacities from9 – 27kW.• Variable <strong>heat</strong>ing water flow temperatures from35ºC – 58ºC with weather compensation.• Stainless steel coil <strong>heat</strong> exchanger providing theopportunity for use with virtually all water qualitieswithout the need for water analysis.• WPM2007 <strong>heat</strong> pump manager with removablecontrol panel.• Suitable for use with underfloor <strong>heat</strong>ing or radiatorsystems and to provide domestic hot water.• Electronic soft start control to reduce start currentloads.High capacitywater to water<strong>heat</strong> <strong>pumps</strong>WI 14 MEModel WI 9 ME WI 14 ME WI 18 TE WI 22 TE WI 27 TEConnection Voltage (V) 230 230 400 400 400Maximum flow temp (°C) 55 55 58 58 58Heat output W10/W35(kW) 8.2 13.5 16.9 21.3 26.1CoP W10/W35 4.8 4.7 5.2 5.3 4.9Please see page 52 for full technical specifications.The new stainless steel spiral <strong>heat</strong>exchanger is a innovative solutionto prevent corrosion and icing up.WI ME and WI TE models cantherefore be used with untreatedground water sources with atemperature of up to 13ºC.WI CG<strong>Dimplex</strong> WI CG high performance water to water<strong>heat</strong> <strong>pumps</strong> provide the solution where highercapacity <strong>heat</strong>ing is required.Available in outputs of 40kW and 90kW, bothmodels utilise the WPM 2006 <strong>heat</strong> pump managerand incorporate twin compressors, enabling themto flexibly and efficiently adapt to fluctuating <strong>heat</strong>demand by automatically switching between singleand dual compressor modes.WI 40 CGRange features• Available with nominal <strong>heat</strong>ing capacities of40 and 90kW.• Variable <strong>heat</strong>ing water flow temperatures from35ºC – 55ºC with weather compensation.• Twin compressors for high capacity output and twoperformance capacities.• WPM2006 <strong>heat</strong> pump manager.• Requires ground water analysis prior to installation.Model WI 40 CG WI 90 CGConnection Voltage (V) 400 400Maximum flow temp (°C) 55 55Heat output W10/W35(kW)1 Compressor 23.4 49.82 Compressors 44.4 91.2CoP W10/W351 Compressor 5.9 5.92 Compressors 5.7 5.4Please see page 52 for full technical specifications.WI ME / WI TE / WI CG35


Reversible<strong>heat</strong> <strong>pumps</strong>Innovative <strong>heat</strong>ing andcooling32675148910Apart from an efficient <strong>heat</strong> pump<strong>heat</strong>ing system, summer time coolingof well-insulated new buildings isbecoming increasingly important toachieve a comfortable environment.Solar gain, higher levels of insulationand increasingly warm summertemperatures all lead to a risingdemand for cooling systems. <strong>Dimplex</strong>offers an innovative, energy efficientconcept for all types of <strong>heat</strong> sourcesto also utilise water-bearing <strong>heat</strong>ingsystems for cooling purposes.12345678910Heat pump manager for <strong>heat</strong>ing and coolingDynamic cooling via fan convectors with condensate drainage; suitable fordomestic buildings with high <strong>heat</strong> loads and commercial buildingsRoom thermostats switch from <strong>heat</strong>ing to cooling via an external signalfrom the cooling controllerSilent cooling utilising existing <strong>heat</strong>ing surfaces (underfloor, ceiling or wallcooling)Room climate control station for regulating the flow temperature with silentcooling via a reference roomUnderfloor <strong>heat</strong>ing for comfortable <strong>heat</strong> in the winterDew point monitor for connection to the cooling controller to interrupt thecooling operation of the system if condensate forms at vulnerable points inthe cooling distribution systemThe waste <strong>heat</strong> produced in cooling operation can be utilised for swimmingpool water <strong>heat</strong>ingEfficient domestic hot water preparation utilising waste <strong>heat</strong> recovery incooling operationReversible air source <strong>heat</strong> <strong>pumps</strong> for outdoor installation36Reversible <strong>heat</strong> <strong>pumps</strong>


Reversible air source <strong>heat</strong> <strong>pumps</strong>Indoor installationModels available:8kW single phase, integrated (LI 8 MEKR)11kW single phase (LI 11 MER)11kW three phase with <strong>heat</strong> recovery (LI 11 TER+)16kW three phase with <strong>heat</strong> recovery (LI 16 TER+)Outdoor installationModels available:11kW single phase (LA 11 MSR)16kW three phase (LA 16 ASR)6-10kW single phase (LA 6-10 MR)12-16kW three phase (LA 12-16 MR)Indoor InstallationLI TER+Outdoor InstallationLA MSR / ASRLA MRReversible <strong>heat</strong> <strong>pumps</strong> for active coolingIn winter the <strong>heat</strong> pump functions as an energy efficient <strong>heat</strong>ingdevice and extracts the required energy from the environment. Byreversing this process the <strong>heat</strong> pump can be operated to providecooling, extracting <strong>heat</strong> from the building and transferring this to theenvironment via the <strong>heat</strong> pump refrigerant and compressor.Waste <strong>heat</strong> recovery makes it possible to also produce domestic hotwater extremely efficiently during the cooling process, while returningwaste <strong>heat</strong> to the ground (using a ground source <strong>heat</strong> pump)effectively stores the energy for use later in the year when needed for<strong>heat</strong>ing. The entire system is controlled by the <strong>heat</strong> pump manager.Passive cooling with borehole <strong>heat</strong> exchangers or groundwater.Deeper ground layers have constant temperature levels of around10°C all year round. This allows ground source <strong>heat</strong> <strong>pumps</strong> installedwith vertical borehole collectors to be used to provide ‘passive’cooling, by transferring excess <strong>heat</strong> from the building to the groundvia the collector in the summer months.This is achieved with the addition of a retro-fittable passivecooling unit, controlled by an additional cooling controller, whichcommunicates with the <strong>heat</strong> pump manager to enable a combinationof <strong>heat</strong>ing and ‘comfort’ cooling in a single system.Domestic hot water can still be provided in parallel to the coolingoperation as the <strong>heat</strong> pump compressor is not active in the passivecooling mode.Depending on the type of <strong>heat</strong>ing system installed in the building,cooling can be provided in one of two ways:Silent (active) cooling via surface <strong>heat</strong>ing systemsIn summer, the <strong>heat</strong>ing surfaces in floors, walls and ceilings areactivated for cooling by passing cooled water through them. Largecooled surfaces cool the rooms to a comfortable temperature withoutdraughts or air movement.Dynamic cooling via fan convectorsIntegrated ventilators guide the indoor air to a <strong>heat</strong> exchanger, which<strong>heat</strong>s or cools the air according to need. Multi-level controllable airrecirculation guarantees short response times and high transmissioncapacities.Reversible ground source <strong>heat</strong> <strong>pumps</strong>Models available:5-11kW single phase (SI 5-11 TER)30kW three phase with <strong>heat</strong> recovery (SI 30 TER+)75kW three phase with <strong>heat</strong> recovery (SI 75 TER+)SI 75 TER+ SI 30 TER+ SI 5-11 MERPlease see technical specification pages for typical system configuration and accessories.Reversible <strong>heat</strong> <strong>pumps</strong>37


Swimmingpool <strong>heat</strong><strong>pumps</strong>Heat <strong>pumps</strong> are the ideal solutionfor swimming pool <strong>heat</strong>ing,providing an economic and energyefficient means of delivering aconstant pool water temperaturethroughout the year.1267Air source <strong>heat</strong> <strong>pumps</strong> are3 4 5particularly suitable due to their lowinstallation cost and high efficiencyat high ambient temperatures duringthe summer – the most frequent time1. Swimming pool <strong>heat</strong> pump2. Remote control3. Pure water to the poolThe <strong>heat</strong> pump is connecteddirectly to the pool system.No additional control.of swimming pool use!4. Circulating pump5. Bypass and regulator valves6. Pipe water from the pool7. Filter38Swimming pool <strong>heat</strong> <strong>pumps</strong>


Swimming pool<strong>heat</strong> <strong>pumps</strong> –air sourceLAS MT & LAS TT<strong>Dimplex</strong> LAS MT and LAS TT air source <strong>heat</strong><strong>pumps</strong> provide an energy efficient and costeffective way of providing swimming pool<strong>heat</strong>ing throughout the year, irrespective of theweather conditions.Purpose designed for swimming pool use andincorporating a titanium <strong>heat</strong> exchanger whichallows the <strong>heat</strong> pump to be used with varyinglevels of water quality, the range is availablein outputs from 10-22kW. The <strong>heat</strong> pumpis installed outdoors and integrated into theswimming pool filter circuit.A single <strong>heat</strong> pump setting ensures the requiredswimming pool water temperature is constantlymaintained.LAS 10 MTRange features• Outdoor installation.• Nominal <strong>heat</strong>ing capacities of 10kW, 15kWand 22kW.• Variable <strong>heat</strong>ing water flow temperaturesup to 40˚C.• Titanium <strong>heat</strong> exchanger ensuring safe operationwith variable water qualities, including salt water.• Integrated automatic defrost cycle, allowingoperation at temperatures as low as – 10˚C.Model LAS 10 MT LAS 15 MT LAS 22 TTConnection Voltage (V) 230 230 400Maximum flow temp (°C) 40 40 40Heat output A20/W24(kW) 12.1 16.6 22.3CoP A20/W24 4.2 4.7 5.1Please see page 52 for full technical specifications.LAS MT / LAS TT39


Heat pumpaccessoriesPerfectly matched4213<strong>Dimplex</strong> <strong>heat</strong> <strong>pumps</strong> offer a varietyof services – providing the home withcomfortable warmth is only one of them. Itcan also provide all the hot water needed forthe kitchen and bathroom.<strong>Dimplex</strong> provides all the components neededfor these applications, including buffer tanks,unvented hot water cylinders and hydraulicaccessories, ensuring the components areoptimally matched to ensure maximumsystem efficiency.1234Buffer TankHeating System ConnectionUnvented Hot Water CylinderWPM Heat Pump ManagerA range of ancillary products designed tosimplify <strong>heat</strong>ing system and ground collectorconnections are also available, ensuringinstallation is as compact and simple aspossible.40Heat pump accessories


Tapping into the <strong>heat</strong> sourceWhen using the outside air as a<strong>heat</strong> source, special componentsfor the air circuit are requiredfor <strong>heat</strong> <strong>pumps</strong> that are installedindoors.These include insulated air ductsand specifically designedrain guards.For ground source <strong>heat</strong><strong>pumps</strong>, brine packages andbrine circuit manifolds areavailable.These are specificallymatched to the requirementsof each type of <strong>heat</strong> pump.Distribution systemModules matching the specificrequirements of the <strong>heat</strong> <strong>pumps</strong>simplify connection to the <strong>heat</strong>ingsystem and offer the option offlexible expansion for domestichot water or additional<strong>heat</strong>ing circuits.ACBThe most common components are;A Compact manifold (KPV25) allows connection between <strong>heat</strong>pump, buffer tank and a single <strong>heat</strong>ing circuit, simplifying theinstallation process and reducing space.B Hot water module (WMM25) allows connection between the<strong>heat</strong> pump and the hot water cylinder.C Manifold bar (VTB25) allows simultaneous connection of thecompact manifold and hot water module.Buffer tanksConnection of a buffer tank ensures minimumcompressor run times and minimum waterflow rates through the <strong>heat</strong> pump to maintainoptimum efficiency. A buffer is essential for airsource <strong>heat</strong> <strong>pumps</strong> as it provides the energyfor defrosting. Where the <strong>heat</strong> pump providesthe sole source of <strong>heat</strong>ing, an electricimmersion element can also be integrated toprovide supplementary <strong>heat</strong>ing if required.Model Capacity Dimensions For use with(litres) (mm)PSW100 100 Ø512x850 Up to 12kWPSP100E 100 740x740x240 All SI ME & SI MEK modelsPSW200 200 Ø600x1300 Up to 30kWPSW500 500 Ø700x1950 All <strong>heat</strong> <strong>pumps</strong>PSP140E 140 750x600x850 Indoor ASHP 11-20kW capacityNote: a suitably sized immersion element must be ordered separately.Hot water cylindersFor the central hot water supply <strong>Dimplex</strong> offers a range of unventedhot water cylinders, sized correctly for the maximum <strong>heat</strong>ing capacityof the <strong>heat</strong> pump.It is important to remember that due to the lower flow temperatures,correctly sized <strong>heat</strong> exchangers are required to maximiseperformance.An integrated temperature sensor is connected to the <strong>heat</strong> pumpmanager, allowing the <strong>heat</strong> pump to automatically manage theproduction of hot water as well when required.Model Capacity Dimensions(litres)(mm)WWSP332UK 300 Ø700x1300WWSP880UK 400 Ø700x1600WWSP900UK 500 Ø700x1950PWS332UK 300+100 buffer Ø700x1800All <strong>Dimplex</strong> <strong>heat</strong> pump cylinders are fullyUK approved for G3 Building regulations.Heat pump accessories41


Heat pumpmanagerEverything is under controlThe majority of <strong>Dimplex</strong> <strong>heat</strong> <strong>pumps</strong> utilise theWPM <strong>heat</strong> pump manager, which is designed toregulate, control and monitor the entire <strong>heat</strong>ingsystem.Water temperatures for up to 3 <strong>heat</strong>ing / hotwater circuits are individually programmable,allowing the <strong>heat</strong> pump to provide maximumflexibility, control and efficiency.Key features:• Simple 6 key operation• Large, well laid out illuminated display• Dynamic menu based programming, customised to the configuration ofthe <strong>heat</strong> pump – settings that are not required are hidden.• Interface for remote control unit with identical menu options• Ground source and indoor air source units have removable control panelfor convenient positioning• Weather compensated temperature control• Control over 3 separate <strong>heat</strong>ing / hot water circuits• Automatic actuation of supplementary <strong>heat</strong> source (electric immersion <strong>heat</strong>eror gas / oil boiler).• Automatic actuation of mixer valves for supplementary <strong>heat</strong> generators(gas / oil boiler or solar energy storage system)42Heat pump accessories


Two <strong>heat</strong> generators and three<strong>heat</strong> consumers:the <strong>heat</strong> pump has everythingunder controlHeating Zone 2The <strong>heat</strong> pump manager monitors theoperation of the <strong>heat</strong> pump and provides allthe functions of a modern <strong>heat</strong>ing regulationsystem, including remote diagnostics andtime programmes for <strong>heat</strong>ing and hot waterpreparation.The <strong>heat</strong> pump, <strong>heat</strong>ing and hot water <strong>pumps</strong>,mixer motor and any supplementary <strong>heat</strong>ingsources are all automatically activated by theWPM manager. For reversible <strong>heat</strong> <strong>pumps</strong> both<strong>heat</strong>ing and cooling modes are managed bythe same controller.Heat pumpHeating Zone 1DHW cylinder and buffer tankSystem integration withexisting systemsThe WPM controller also allows <strong>Dimplex</strong> <strong>heat</strong><strong>pumps</strong> to be efficiently integrated in ‘bi-valent’mode with existing systems. When combined inparallel with an existing boiler, the <strong>heat</strong> pumpmanager regulates the boiler in accordance toneed and ensures that no excessive temperaturescan enter the <strong>heat</strong>ing system.This way, for example, a filled oil tank can beused up before converting to <strong>heat</strong> pump onlyoperation later on, or provide the ability for the<strong>heat</strong> pump to manage the base <strong>heat</strong>ing loadwith supplementary support from an existinggas boiler. Such strategies provide an excellentopportunity for the installation of <strong>heat</strong> <strong>pumps</strong> inexisting homes and buildings.Integration with the renewablesFor optimal integration of renewable <strong>heat</strong>sources, the <strong>heat</strong> pump manager offers anoperating mode developed especially forpurpose. Thermal solar energy systems orbiomass boilers feed into a renewable cylinderfitted with an additional <strong>heat</strong> exchanger which,at a sufficient temperature level, gives priorityto this energy for <strong>heat</strong>ing or hot water, overriding the operation of the <strong>heat</strong> pump.Heat pump accessories43


technical specificationsTYPICAL SYSTEM CONFIGURATION AND ACCESSORIESOutdoor Air Source Heat Pumps: LAK M / LA MR / LA TR rangesThe diagram below shows a typical LAK M / LA MR / LA TR <strong>heat</strong> pump configuration for <strong>heat</strong>ingand domestic hot water including typical accessories required for a single <strong>heat</strong>ing circuit.(Note this is for illustrative purposes only and is not intended as a full hydraulic schematic)RemoteControlHeat PumpLAK 10 MAir source <strong>heat</strong> pump(<strong>heat</strong>ing) 1LA 6/8/10 MR / LA 12/16 TR Air source <strong>heat</strong> pump(<strong>heat</strong>ing / cooling) 1Heating and Hot Water AccessoriesQtyDHWCylinderHeatingCircuitBufferTankLA MR/TRHeat PumpPSW100/200 100L/200L Buffer tank 1WWSP332UK/880UK 300/400L Hot water cylinder 1Controller AccessoriesWPR 2007 Heat pump controller 1Outdoor Air Source: LA MS rangeReversible Outdoor Air Source Heat Pumps:LA MSR rangeThe diagram below shows typical LA MS / LA MSR <strong>heat</strong> pump configurationfor <strong>heat</strong>ing and domestic hot water including typical accessories required for asingle <strong>heat</strong>ing circuit.(Note this is for illustrative purposes only and is not intended as a full hydraulic schematic)DHWCylinderHeatingCircuitBufferTankKPV25VTB 25WWM25WPMControlUnitHeat PumpHeat PumpQtyLA 11/16 MS Air source <strong>heat</strong> pump (<strong>heat</strong>ing) 1LA 11 MSR Air source <strong>heat</strong> pump (<strong>heat</strong>ing/cooling) 1Heating and Hot Water AccessoriesWWSP332UK/WWSP880UK 300L/400L domestic hot water cylinder 1PSW100/PSW200 100L/200L buffer tank 1UP60/UP80 Heating/DHW circulation <strong>pumps</strong> 1CTHK631/2/3/4/5 Buffer immersions 1KPV25* Compact manifold 1EBKPV* Extension module for KPV 1WWM25* Heating circuit/hot water module 1VTB25* Manifold bar 1Controller AccessoriesEVL 995/6/7/8-1 Controller connecting cable (<strong>heat</strong>ing) 1EVL 10/20/30RController connecting cable(<strong>heat</strong>ing/cooling) 1* Dependent on required <strong>heat</strong> pump flow rate – see page 54 for detailsOutdoor Air Source Heat Pumps: LA AS rangeReversible Outdoor Air Source Heat Pumps:LA ASR rangeThe diagram below shows typical LA AS / LA ASR <strong>heat</strong> pump configuration for<strong>heat</strong>ing and domestic hot water including typical accessories required for asingle <strong>heat</strong>ing circuit.(Note this is for illustrative purposes only and is not intended as a full hydraulic schematic)DHWCylinderHeatingCircuitBufferTankEBKPVKPV25VTB 25WWM25WPMControlUnitHeat PumpHeat PumpQtyLA 20/24/28/40 AS Air source <strong>heat</strong> pump (<strong>heat</strong>ing) 1LA 16 ASR Air source <strong>heat</strong> pump (<strong>heat</strong>ing/cooling) 1Heating and Hot Water AccessoriesWWSP332UK/WWSP880UK 300L/400L domestic hot water cylinder 1PSW500 500L buffer tank 1UP60/UP80 Heating/DHW circulation <strong>pumps</strong> 1UP32-70 Heating/DHW circulation <strong>pumps</strong> 1CTHK631/2/3/4/5 Buffer immersions 1FLH60 Three phase 6.0kW flange <strong>heat</strong>er 1FLHU70Three phase 2.0/2.7/4.0kW variableoutput flange <strong>heat</strong>er 1DDV32* Dual differ. pressure less module 1KPV25* Compact manifold 1EBKPV* Extension module for KPV 1WWM25* Heating circuit/hot water module 1VTB25* Manifold bar 1Controller AccessoriesEVL 995/6/7/8-1 Controller connecting cable (<strong>heat</strong>ing) 1EVL 10/20/30RController connecting cable(<strong>heat</strong>ing/cooling) 1* Dependent on required <strong>heat</strong> pump flow rate – see page 54 for details44Technical specification


LAK 10 M LA 6 MR LA8 MR LA10 MR LA12TR LA16TROperating LimitsHeating water system/return °C max 58 / min 18 max 60 / min 18Air °C -20 to +35 -20 to +35Cooling flow °C - +7 to +20Air °C - +15 to +40PerformanceHeating capacity A7 /W35 (kW) 1 10.2 6.1 7.4 8.5 11.9 15.3Coefficient of performance A7 /W35 4.1 3.3 3.3 3.4 3.3 3.3Cooling Capacity A35/W18 (kW) 1 - 7.9 9.3 11.1 15.8 18.5Coefficient of performance A35 /W18 - 3.2 3.3 3.3 3.3 3.3Minimum <strong>heat</strong>ing flow @ internal pressuredifferential (m 3 /h/Pa) 0.8 / 1100 1.1 1.3 1.5 1.7 1.9Sound Pressure level at 10m dB (A) 46 45 46 46 47 47Refrigerant: type/total charge weight (kg) R404A / 2.3 R407C / 1.5 R407C / 2.3 R407C / 2.7 R407C / 3.4 R407C / 3.5Dimensions HxWxL (mm) 880x1285x695 860x1270x670 860x1270x670 860x1270x670 860x1270x670 860x1270x670Weight (including packaging) (kg) 185 159 165 170 185 196Electric <strong>heat</strong>ing element (max) (kW) 2/4/6 2/4/6 2/4/6 2/4/6 2/4/6 2/4/6Normal Voltage / fuse rating (V/A) 230 / 25 230 / 20 230 / 20 230 / 25 400 / 20 400 / 25Starting current with soft starter (A) 32 26 32 38 26 271Performance standards measured to EN255LA 11 MS LA 11 MSR LA 16 MSOperating limitsHeating water supply/return °CMax55 / min18Air °C -20 to +35Cooling flow °C - +7 to +20 -Air °C - +15 to +40 -PerformanceHeating capacity A7/W35 (kW) 1 10.9 11.1 15.4Coefficient of performance A7/W35 1 4.1 4.2 3.7Cooling capacity A27/W18 (kW) 1 - 10.9 -Coefficient of performance A27/W18 1 - 3.3 -Minimum <strong>heat</strong>ing flow @ internal pressuredifferential (m 3 /h/Pa) 1.0 / 3000 1.0 / 3000 1.4 / 4500Sound Pressures Level at 10m dB (A) 33 33 34Refrigerant: type/total charge weight (kg) R404A / 2.5 R404A / 3.6 R404A / 3.1Dimensions HxWxL (mm) 1360x1360x850 1360x1360x850 1570x1550x850Weight (including packaging) (kg) 219 224 264Normal voltage / fuse rating (V/A) 230 / 25 230 / 25 230 / 32Starting current with soft starter (A) 38 38 451Performance standards measured to EN255LA 16 ASR LA 20 AS LA 24 AS LA 28 AS LA 40 ASOperating limitsHeating water supply/return °CMax55 / min18Air °C -20 to +35Cooling flow °C +7 to +20 - - - -Air °C +15 to +40 - - - -PerformanceHeating capacity A7/W35 (kW) 11 compressor 15.1 9.8 13.1 14.2 20.22 compressors - 16.6 24.8 25.8 36.3Coefficient of performance A7/W35 11 compressor 3.8 3.2 3.4 3.1 4.72 compressors - 3.1 3.6 3.4 4.5Cooling capacity A27/W18 (kW) 1 16.4 - - - -Coefficient of performance A27/W18 1 2.8 - - - -Minimum <strong>heat</strong>ing flow @ internal pressuredifferential (m 3 /h/Pa) 1.4 / 4500 1.8 / 3700 2.3 / 5900 2.3 / 3100 4.0 / 1700Sound Pressures Level at 10m dB (A) 34 37 41 41 43Refrigerant: type/total charge weight (kg) R404A / 5.7 R404A / 3.7 R404A / 4.2 R404A / 4.2 R404A / 11.8Dimensions HxWxL (mm) 1570x1550x850 1570x1550x850 1710x1680x1000 1710x1680x1000 2100x1735x890Weight (including packaging) (kg) 289 284 351 355 585Normal voltage / fuse rating (V/A) 400 / 20 400 / 20 400 / 25 400 / 25 400 / 25Starting current with soft starter (A) 25 23 24 25 301Performance standards measured to EN255For additional hydraulic modules please refer to page 54.Technical specification45


Outdoor Air Source Heat Pumps:LA PS / LA HS rangesThe diagram below shows typical LA PS / LA HS <strong>heat</strong> pump configuration for<strong>heat</strong>ing and domestic hot water including typical accessories required for asingle <strong>heat</strong>ing circuit.(Note this is for illustrative purposes only and is not intended as a full hydraulic schematic)DHWCylinderHeatingCircuitBufferTankEB KPVKPV25VTB25WWM25WPMcontrol unitHeat PumpControllerHeat PumpHeat PumpLA 9/11/17/22/26 PSLA 22/26 HSQtyAir source <strong>heat</strong> pump(medium temp) 1Air source <strong>heat</strong> pump(high temp) 1Heating and Hot Water AccessoriesWWSP332UK/880UK/900UK 300L/400L/500Ldomestic hot water cylinder 1PSW100/PSW200 100L/200L buffer tank 1UP60/UP80 Heating/DHW circulation <strong>pumps</strong> 1CTHK631/2/3/4/5 Buffer immersions 1DDV32* Dual differ. pressure less module 1KPV25* Compact manifold 1EBKPV* Extension module for KPV 1WWM25* Heating circuit/hot water module 1VTB25* Manifold bar 1Controller AccessoriesEVL 995/6/7/8-1Controller connecting cable(<strong>heat</strong>ing) 1* Dependent on required <strong>heat</strong> pump flow rate – see page 54 for detailsIndoor Air Source Heat Pumps: LI 8 MEK / LI 8 MEKR rangesThe diagram below shows typical LI 8 MEK and LI 8 MEKR <strong>heat</strong> pumpconfiguration for <strong>heat</strong>ing and domestic hot water including typicalaccessories required for a single <strong>heat</strong>ing circuit.(Note this is for illustrative purposes only and is not intended as a full hydraulic schematic)DHWCylinderHeatingCircuitLI 8 MEKHeat PumpLKLLKBLKK500IntegralBufferTankRSG500Heat PumpQtyLI 8 MEK Air source <strong>heat</strong> pump (<strong>heat</strong>ing) 1LI 8 MEKRAir source <strong>heat</strong> pump(<strong>heat</strong>ing and cooling) 1Heating and Hot Water AccessoriesWWSP332UK 300L domestic hot water cylinder 1UP60 Heating/DHW circulation <strong>pumps</strong> 1Ducting AccessoriesLKL / LKK / LKB 500Long, short or 90° elbow ducts(depending on requirement) 1 or 2DMK500 Sealing collar 1RSG500 Rain guard 2Indoor Air Source Heat Pumps: LI ME / LI TE rangesHigh Temperature Indoor Air Source Heat Pumps:LI TEH rangeThe diagram below shows a typical LI ME/LI TE/LI TEH <strong>heat</strong> pumpconfiguration for <strong>heat</strong>ing and domestic hot water includingtypical accessories required for a single <strong>heat</strong>ing cicuit.(Note this is for illustrative purposes only and is notintended as a full hydraulic schematic)DHWCylinderHeatingCircuitKPV25BufferTankEB KPVVTB25WWM25WPMControlUnitHeat PumpLKLLKBLKK600/700/800RSG 600/700/800Heat PumpQtyLI 11 ME / LI 16/20/24/28 TE Air source <strong>heat</strong> pump 1LI 22 / 26 TEH Air source <strong>heat</strong> pump (High temp) 1Heating and Hot Water AccessoriesWWSP332UK/880UK/900UK 300L/400L/500Ldomestic hot water cylinder 1PSP140E140L built under buffer tank(LI 11/16/20) 1CTHK 631/2/3/4/5/6 Buffer immersion 1SAS110 Connection hoses 1UP60/UP80 Heating/DHW circulation <strong>pumps</strong> 1FLH60 Three phase 6.0kW flange <strong>heat</strong>er 1FLHU70Three phase 2.0/2.7/4.0kW variableoutput flange <strong>heat</strong>er 1DDV32* Dual differ. pressure less module 1KPV25* Compact manifold 1EBKPV* Extension module for KPV 1WWM25* Heating circuit/hot water module 1VTB25* Manifold bar 1Ducting AccessoriesLKL600 / 700 / 800 Long duct (as required) 1 or 2LKK600 / 700 / 800 Short duct (as required) 1 or 2LKB600 / 700 / 800 90° elbow duct (as required) 1 or 2DMK600 / 700 / 800 Sealing collar 1RSG600 / 700 / 800 Rain guard 246Technical specification* Dependent on required <strong>heat</strong> pump flow rate – see page 54 for details


LA 9 PS LA11 PS LA17 PS LA 22 PS LA 26 PS LA 22 HS LA 26 HSOperating limitsHeating water supply/return °C Max 65 / min 18 Max 75 /min 18Air °C -20 to + 35PerformanceHeating capacity A7 / W35 (kW) 11 compressor 8.5 11.2 9.6 12.0 13.3 15.4 19.82 compressors - - 16.6 21.1 22.9 - -Coefficient of Performance A7/ W35 11 compressor 3.6 3.5 3.4 3.6 3.5 3.4 3.82 compressors - - 3.4 3.5 3.5 - -Minimum <strong>heat</strong>ing flow @ internal pressuredifferential (m 3 /h/Pa) 1.2 / 9000 1.1 / 2600 1.6 / 2900 2.0 / 4500 2.2 / 3100 1.8 / 3000 1.8 / 3000Sound Pressures Level at 10m dB (A) 34 34 37 41 41Refrigerant: type/total charge weight (kg) R404A / 3.3 R404A / 3.7R290 / 1.0 R290 / 1.5 R290 / 1.8 R290 / 2.2 R290 / 2.5 R134A / 2.7 R134A / 3.1Dimensions H x W x L (mm) 1320x770x660 1570x1550x850 1570x1550x850 1710x1680x1000 1710x1680x1000 1710x1680x1000 1710x1680x1000Weight (including packaging) (kg) 168 258 330 360 371 411 418Nominal Voltage / fuse rating (V/A) 400 / 16 400 / 16 400 / 20 400 / 20 400 / 25 400 / 25 400 / 25Starting current with soft starter (A) 28 30 23 25 30 25 301Performance standards measured to EN14511LI 8 MEK LI 8 MEKROperating limitsHeating water supply/return °C Max 55 / min 18Air °C -25 to +35Cooling water supply °C +7 to +20Air °C +15 to +40PerformanceHeating capacity A7 / W35 (kW) 1 9.2 9.2Coefficient of Performance A7 / W35 1 3.8 3.8Cooling capacity A27 / W18 (kW) 1 - 9.6Coefficient of Performance A27 / W18 1 - 3.2Minimum <strong>heat</strong>ing flow @internal pressuredifferential (m 3 /h/Pa) 0.8 / 2700 0.8 / 2700Sound Pressure level at 1m dB (A) (indoors) 48Refrigerant: type/total charge weight (kg) R404A / 2.0 R404A / 3.3Dimensions H x W x L (mm)1900x750x680 1900x750x680Weight (including packaging) (kg) 245 250Buffer tank capacity (L) 50 50Electric <strong>heat</strong>ing element (kW) 2 2Nominal Voltage / fuse rating (V/A) 230 / 20 230 / 20Starting current with soft starter (A) 30 301Performance standards measured to EN14511LI 11 ME LI 16 TE LI 20 TE LI 24 TE LI 28 TE LI 22 TEH LI 26 TEHOperating limitsHeating water supply/return °C Max 58 / min 18 Max 75 / min18Air °C -25 to +35PerformanceHeating capacity A7/W35 (kW) 11 compressor 10.9 15.1 10.4 12.6 13.9 15.2 19.52 compressors - - 17 24.2 25.1 - -Coefficient of performance A7/W35 11 compressor 3.9 3.6 3.5 3.3 3.1 3.2 3.62 compressors - - 3.4 3.4 3.3 - -Minimum <strong>heat</strong>ing flow @ internal pressuredifferential (m 3 /h/Pa) 1.0 / 3000 1.4 / 4500 1.8 / 3700 2.3 / 5900 2.3 / 3100 1.8 / 3700 1.8 / 3700Sound Pressure level at 1m dB (A) (Indoors) 50 52 54 58 58 58 58Refrigerant: type/total charge weight (kg) R404A / 3.3 R404A / 3.7R404A / 2.5 R404A / 3.1 R404A / 3.7 R404A / 4.2 R404A / 4.3 R134A / 2.7 R134A / 3.1Dimensions H x W x L (mm) 1360x750x880 1570x750x880 1570x1550x880 l710x750x1030 1710x7500x1030 1710x7500x1030 1710x7500x1030Weight (including packaging) (kg) 200 235 255 310 314 370 377Electric <strong>heat</strong>ing element (kW) - - 6 - - - -Nominal Voltage / fuse rating (V/A) 230 / 25 400 / 32 400 / 20 400 / 25 400 / 25 400 / 25 400 / 25Starting current with soft starter (A) 38 25 23 24 25 25 301Performance standards measured to EN14511For additional hydraulic modules please refer to page 54.Technical specification47


Reversible Indoor Air Source Heat Pumps:LI MER / LI TER+ rangesThe diagram below shows a typical LI MER / LI TER+ <strong>heat</strong> pumpconfiguration for <strong>heat</strong>ing and domestic hot water including typicalaccessories for a single <strong>heat</strong>ing circuit.(Note this is for illustrative purposes only and is notintended as a full hydraulic schematic)DHWCylinderHeatingCircuitKPV25BufferTankVTB25WWM25WPMControlUnitHeat PumpLKLLKBLKK600/700/800600/700/800Heat PumpQtyLI 11 MER/LI 11 TER + Air source <strong>heat</strong> pump 1LI 16 TER/16 TER+Heating and Hot Water AccessoriesWWSP332UK300L domestichot water cylinder 1PSP140E140L built underbuffer tank 1CTHK 631/2/3/4/5/6 Buffer immersion 1SAS110 Connection hoses 1KPV25* Compact manifold 1EBKPV* Extension module for KPV 1WWM25* Heating circuit/hot water module 1VTB25* Manifold bar 1Controller AccessoriesEVL10/20/30RController connecting cable(<strong>heat</strong>ing/cooling) 1Ducting AccessoriesLKL600 / 700 / 800 Long duct (as required) 1 or 2LKK600 / 700 / 800 Short duct (as required) 1 or 2LKB600 / 700 / 800 90° elbow duct (as required 1 or 2DMK600 / 700 / 800 Sealing collar 1RSG600 / 700 / 800 Rain guard 2* Dependent on required <strong>heat</strong> pump flow rate – see page 54 for detailsGround Source Heat Pumps: SI ME rangeHigh Temperature Ground Source Heat Pumps: SI MEH rangeReversible Ground Source Heat Pumps: SI MER rangeThe diagram below shows a typical SI ME / SI MEH / SI MER <strong>heat</strong>pump configuration for <strong>heat</strong>ing and domestic hot water including typicalaccessories required for a single <strong>heat</strong>ing cicuit.(Note this is for illustrative purposes only and is not intended as a full hydraulic schematic)DHWCylinderHeatingCircuitKPV25VTB25WWM25Heat PumpQtySI 5/7/9/11/14 ME Ground source <strong>heat</strong> pump (<strong>heat</strong>ing) 1SI 6/9/11 MEH Ground source <strong>heat</strong> pump (high temp) 1SI 5/7/9/11 MERGround source <strong>heat</strong> pump(<strong>heat</strong>ing and cooling) 1Heating and Hot Water AccessoriesWWSP332UK/WWSP880UK 300L/400L domestic hot water cylinder 1PSW100/PSW200 100L/200L buffer tank 1PSP100E 100L under buffer cylinder 1UP60/UP80 Heating/DHW circulation <strong>pumps</strong> 1VSHBS Connection hoses 1PWS332UK100L buffer cylinder/300L DHWcombination cylinder 1KPV25* Compact manifold 1EBKPV* Extension module for KPV 1WWM25* Heating circuit/hot water module 1VTB25* Manifold bar 1Ground Controller AccessoriesSZB 680/690 Ground loop circuit package 1APSVTGround loop circuit manifoldconnection kit 1SVT200 / 300 / 400 Ground circuit manifold (2/3/4 circuits) 1* Dependent on required <strong>heat</strong> pump flow rate – see page 54 for detailsBufferTankHeat PumpSZB 680/690APSVTAPSVTSVT 200/300/40048Technical specification


LI 11 MER LI 11 TER+ LI 16 TER+Operating LimitsHeating water supply/return °C Max 58 / min 18Air °C -25 to +35Cooling water supply °C +7 to +20Air °C +15 to +40PerformanceHeating capacity A7 / W35 (kW) 1 11.1 11.3 14.9Coefficient of Performance A7 / W35 1 4.2 3.6 3.6Cooling capacity A27 / W18 (kW) 1 10.9 10.8 16.4Coefficient of Performance A27 / W18 1 3.3 5.2 2.8Minimum <strong>heat</strong>ing flow @ internal pressuredifferential (m 3 /h/Pa) 1.0 / 3000 1.0 / 3000 1.4 / 4500Heat recovery for DHW - • •Sound Pressure level at 1m dB (A) (Indoors) 50 50 52Refrigerant: type/total charge weight (kg) R404A / 3.6 R404A / 5.1 R404A / 5.7Dimensions HxWxL (mm) 1360x750x880 1360x750x880 l570x750x880Weight (including packaging) (kg) 250 222 260Normal Voltage / fuse rating (V/A) 230/25 400/16 400/20Starting current with soft starter (A) 38 23 25SI 5 ME SI 7 ME SI 9 ME SI 11 ME SI 14 MEOperating LimitsHeating water supply/return °C Max 58 / min 18Brine (<strong>heat</strong>ing) °C -5 to +25Anti-freeze agentMonoethylene glycolMinimum anti-freeze concentration 25% 25% 25% 25% 25%PerformanceHeating capacity B0 / W35 1 4.9 6.3 8.9 10.8 14.8Coefficient of Performance B0 / W35 1 3.8 3.7 3.8 3.9 3.9Minimum <strong>heat</strong>ing flow @internal pressuredifferential (m 3 /h/Pa) 0.45 / 1900 0.6 / 3300 0.75 / 2300 1.0 / 4100 1.3 / 4800Sound power level dB (A) 54 55 56 56 56Refrigerant: type/total charge weight (kg) R407C / 1.2 R407C / 1.4 R407C / 1.7 R407C / 1.9 R407C / 2.2Dimensions H x W x L (mm) 805x650x462 805x650x462 805x650x462 805x650x462 805x650x462Weight (including packaging) (kg) 109 111 118 122 130Nominal Voltage / fuse rating (V/A) 230 / 16 230 / 16 230 / 20 230 / 25 230 / 32Starting current with soft starter (A) 24 26 38 38 50SI 6 MEH SI 9 MEH SI 11 MEHOperating LimitsHeating water supply/return °C Max 70 / min 18Brine (<strong>heat</strong>ing) °C -5 to +25Anti-freeze agentMonoethylene glycolMinimum anti-freeze concentration 25% 25% 25%PerformanceHeating capacity B0 / W35 6 8.9 10.7Coefficient of Performance B0 / W35 4.1 4.0 4.5Minimum <strong>heat</strong>ing flow @internal pressuredifferential (m 3 /h/Pa) 0.5 / 1200 0.76 / 1700 1.0 / 1600Sound power level dB (A) 56 56 57Refrigerant: type/total charge weight (kg) R134A / 1.2 R134A / 2.2 R134A / 2.4Dimensions H x W x L (mm) 805x650x462 805x650x462 805x650x462Weight (including packaging) (kg) 118 130 133Nominal Voltage / fuse rating (V/A) 230 / 20 230 / 25 230 / 32Starting current with soft starter (A) 38 43 45SI 5 MER* SI 7 MER* SI 9 MER* SI 11 MER*Operating Limits (cooling)Cooling water supply °C +7 to +20Brine (cooling) °C -5 to +25PerformanceHeating capacity B0 / W35 (kW) 1 4.9 6.4 9.3 11.6Coefficient of Performance B0 / W35 1 3.9 3.8 4.0 4.1Cooling capacity B10 / W35 (kW) 6.8 8.8 12.4 14.1Coefficient of Performance B10 / W18 6.7 6.6 6.7 6.5Minimum <strong>heat</strong>ing flow @internal pressuredifferential (m 3 /h/Pa) 0.45 / 1900 0.6 / 3300 0.75 / 2300 1.0 / 4100Refrigerant: type/total charge weight (kg) R407C / 0.9 R407C / 0.9 R407C / 1.25 R407C / 1.6Weight (including packaging) (kg) 115 117 124 128Nominal Voltage / fuse rating (V/A) 230 / 16 230 / 16 230 / 20 230 / 25Starting current with soft starter (A) 24 26 38 381Performance standards measured to EN14511*Heating mode performance as per equivalent SI ME modelFor additional hydraulic modules please refer to page 54.Technical specification49


Integrated Ground Source Heat Pumps: SI MEK rangeIntergrated High Temperature Ground Source Heat Pumps: SI MEKH rangeThe diagram below shows a typical SI MEK <strong>heat</strong> pump configuration for<strong>heat</strong>ing and domestic hot water including typical accessories required fora single <strong>heat</strong>ing cicuit.(Note this is for illustrative purposes only and is not intended as a full hydraulic schematic)DHWCylinderHeatingCircuitHeat PumpQtySI 11/16 MEK Ground source <strong>heat</strong> pump 1SI 9 MEKH Ground source <strong>heat</strong> pump (high temp) 1Heating and Hot Water AccessoriesPSP100E 100L under-unit buffer tank 1VSH KS Buffer tank connection hose 1WWSP 442EUK 400L hot water storage tank 1VSW KS Hot water tank connection hose 1UP60/UP80 Heating/DHW circulation <strong>pumps</strong> 1Ground Loop AccessoriesAPSVT Ground loop manifold connection kit 1 pairSVT200/300/400 Ground circuit manifold 2/3/4 circuits 1 pairHeat PumpBufferTankAPSVTAPSVTSVT 200/300/400Ground Source Heat Pumps: SI TE range (17 – 37kW)Reversible Ground Source Heat Pumps: SI TER+ rangeThe diagram below shows a typical SI TE <strong>heat</strong> pump configuration for<strong>heat</strong>ing and domestic hot water including typical accessories required fora single <strong>heat</strong>ing cicuit.(Note this is for illustrative purposes only and is not intended as a full hydraulic schematic)DHWCylinderHeatingCircuitEB KPVKPV25VTB25WWM25Heat PumpQtySI17/21/24/30/37 TE Ground Source Heat Pump 1Heating and Hot Water AccessoriesPSW200/500 200L/500L buffer tank 1WWSP880UK/900UK 400L/500L Domestic hot water cylinder 1UP60/UP80 Heating/DHW circulation <strong>pumps</strong> 1UP32-70 Heating/DHW circulation <strong>pumps</strong> 1FLH60 Three phase 6.0kW flange <strong>heat</strong>er 1FLHU70Three phase 2.0/2.7/4.0kW variableoutput flange <strong>heat</strong>er 1DDV32* Dual differ. pressure less module 1KPV25* Compact manifold 1EBKPV* Extension module for KPV 1WWM25* Heating circuit/hot water module 1VTB25* Manifold bar 1Ground Loop AccessoriesSZB700/710/250/400 Ground loop circuit package 1APSVT † Ground circuit manifold connection kit 1SVT200/300/400 † Ground circuit manifold 2/3/4 circuits 1* Dependent on required <strong>heat</strong> pump flow rate – see page 54 for details†not suitable for SI 24/37 TEBufferTankSI TEHeat Pump528/700/710/240/300 APSVTAPSVTSVT 200/300/40050Technical specification


SI 11 MEK SI 16 MEK SI 9 MEKHOperating limitsHeating water supply/return °C Max 55 / min 18 Max 70 / min 18Brine (<strong>heat</strong>ing) °C -5 to +25Anti-freeze agentMonoethylene glycolMinimum anti-freeze concentration 25% 25% 25%PerformanceHeating capacity B0 / W35 1 (kW) 11.8 15.8 9.4Coefficient of Performance B0 / W35 4.4 4.2 4.4Minimum <strong>heat</strong>ing flow @internal pressuredifferential (m 3 /h/Pa) 1.0 / 3500 1.3 / 3500 0.75 / 1800Sound power level dB (A) 51 51 49Refrigerant: type/total charge weight (kg) R407C / 2.0 R407C / 2.3 R134A / 2.7Dimensions H x W x L (mm) 1115x652x688 1115x652x688 1115x652x688Weight (including packaging) (kg) 191 203 203Nominal Voltage / fuse rating (V/A) 230 / 25 230 / 32 230 / 25Starting current with soft starter (A) 38 50 431Performance standards measured to EN255SI 17 TE SI 21 TE SI 24 TE SI 30 TE SI 30 TER+ SI 37TEOperating LimitsHeating water supply/return °C Max 58 / min 18Brine (<strong>heat</strong>ing) °C -5 to +25Anti-freeze agentMonoethylene glycolMinimum anti-freeze concentration 25% 25% 25% 25% 25% 25%Operating Limits (Cooling)Cooling water supply - - - - 5°C to 30°C -Brine (cooling) °C - - - - -5 to +25°C -Performance (Heating)Heating capacity B0 / W35 (kW) 11 compressor 16.9 20.8 12.7 14.4 15.2 18.32 compressors - - 23.7 31.2 28.6 35.4Coefficient of Performance B0 / W35 11 compressor 4.4 4.1 4.3 4.2 4.2 4.52 compressors - - 4.1 4.6 3.8 4.3Performance (Cooling)Heating capacity B10 / W18 (kW) 11 compressor - - - - 25.4 -2 compressors - - - - 46.7 -Coefficient of Performance B10 / W18 11 compressor - - - - 9.5 -2 compressors - - - - 7.4 -Minimum <strong>heat</strong>ing flow @internal pressuredifferential (m 3 /h/Pa) 1.5 / 4000 1.6 / 4600 2.2 / 3100 2.6 / 1100 4.7 / 2200 3.2 / 1650Sound power level dB (A) 58 59 59 62 62 63Refrigerant: type/total charge weight (kg) R407C / 2.3 R407C / 4.5 R404A / 3.7 R404A / 7.7 R404A / 8.1 R404A / 6.8Dimensions H x W x L (mm) 805x650x462 1445x650x575 1660x1000x775 1440x775x1000 1660x1000x775 1660x1000x775Weight (including packaging) (kg) 133 225 282 365 385 371Nominal Voltage / fuse rating (V/A) 400 / 16 400 / 20 400 / 20 400 / 20 400 / 20 400 / 20Starting current with soft starter (A) 27 29 20 25 26 261Performance standards measured to EN14511For additional hydraulic modules please refer to page 54.Technical specification51


High Output Ground Source Heat Pumps: SI TE range (50 – 130kW)High Temperature Ground Source Heat Pumps: SI TEH rangeReversible Ground Source Heat Pumps: SI TER+ rangeThe diagram below shows a typical SI TE / SI TEH <strong>heat</strong> pumpconfiguration for <strong>heat</strong>ing and domestic hot water including typicalaccessories required for a single <strong>heat</strong>ing cicuit.(Note this is for illustrative purposes only and is not intended as a full hydraulic schematic)DHWCylinderHeatingCircuitHeat PumpQtySI50/75/100/130TE & SI 20/40TEH Ground Source Heat Pump 1Heating and Hot Water AccessoriesPSW500 500L buffer tank 1/2WWSP900UK 500L Domestic hot water cylinder 1FLH60 Three phase 6.0kW flange <strong>heat</strong>er 1FLHU70Three phase 2.0/2.7/4.0kWvariable output flange <strong>heat</strong>er 1Ground Loop AccessoriesSZB500/750/1000/1300 & SZB250/400BufferTankHeat PumpSZB500-750-1000-1300-240-400Water to Water Heat Pumps:WI ME / WI TE / WI CG rangesThe diagram below shows a typical WI ME / WI TE / WI CG <strong>heat</strong>pump configuration for <strong>heat</strong>ing and domestic hot water including typicalaccessories required for a single <strong>heat</strong>ing cicuit.(Note this is for illustrative purposes only and is not intended as a full hydraulic schematic)DHWCylinderHeatingCircuitBufferTankKPV25VTB25WMMV25Heat PumpHeat PumpQtyWI9/14/18/22/27/40/90 Water Source Heat Pump 1Heating and Hot Water AccessoriesPSW100/200/500 300L/500L buffer tank 1PWS332UK100L buffer cylinder/300L DHWcombination cylinder 1WWSP332UK/880UK/900UK 300L/400L/500Ldomestic hot water cylinder 1UP60/UP80 Heating/DHW circulation <strong>pumps</strong> 1FLH60 Three phase 6.0kW flange <strong>heat</strong>er 1FLHU70Three phase 2.0/2.7/4.0kW variableoutput flange <strong>heat</strong>er 1DDV32* Dual differ. pressure less module 1KPV25* Compact manifold 1EBKPV* Extension module for KPV 1WWM25* Heating circuit/hot water module 1VTB25* Manifold bar 1* Dependent on required <strong>heat</strong> pump flow rate – see page 54 for detailsSwimming Pool Heat Pumps: LAS MT / LAS TT rangesThe diagram shows a typical LAS MT / LAS TT <strong>heat</strong> pump configuration forswimming pool <strong>heat</strong>ing.(Note this is for illustrative purposes only and is not intended as a full hydraulic schematic)SwimmingPoolRemoteControlLA MT/TTHeat Pump52Technical specification


SI 50 TE SI 75 TE SI 75 TER+ SI 100 TE SI 130 TE SI 20 TEH SI 40 TEHOperating limitsHeating water supply/return °C Max 60 / min 18 Max 70 / min 18Brine (<strong>heat</strong>ing) °C -5 to +25Anti-freeze agentMonoethylene glycolMinimum anti-freeze concentration 25% 25% 25% 25% 25% 25% 25%PerformanceHeating capacity B0 / W35 (kW)1 compressor 23.0 1 37.6 1 35.1 1 48.4 1 63.3 1 11.5 2 17.4 22 compressors 46.7 1 75.2 1 65.3 1 96.3 1 125.8 1 21.4 2 34.2 2Coefficient of Performance B0 / W351 compressor 4.4 1 4.3 1 3.8 1 4.6 1 4.2 1 4.6 2 4.1 22 compressors 4.5 1 4.4 1 3.5 1 4.6 1 4.3 1 4.4 2 4.1 2Cooling capacity B10 / W18 (kW)1 compressor - - 53.2 - - - -2 compressor - - 98.2 - - - -Coefficient of Performance B10 / W181 compressor - - 8.2 - - - -2 compressors - - 6.3 - - - -Minimum <strong>heat</strong>ing flow @ internal pressuredifferential (m 3 /h/Pa) 4.5 / 2000 6.5 / 2500 11 / 6000 8.5 / 3600 11.5 / 2200 1.9 / 2310 3.2 / 1100Sound power level dB (A) 50 54 54 55 56 47 50Refrigerant: type/total charge weight (kg) R404A / 8.6 R404A / 14.1 R404A / 16.1 R404A / 20.5 R404A / 27.0 R134A / 4.2 R134A / 8.0Dimensions H x W x L (mm) 1890x1350x775 1890x1350x775 1890x1350x775 1890x1350x775 1890x1350x775 1660x1000x775 1890x1350x775Weight (including packaging) (kg) 486 571 607 652 860 307 502Nominal Voltage / fuse rating (V/A) 400 / 50 400 / 63 400 / 63 400 / 80 400 / 80 400 / 25 400 / 63Starting current with soft starter (A) 56 105 105 120 115 30 841Performance standards measured to EN2552Performance standards measured to EN14511WI 9 ME WI 14 ME WI 18 TE WI 22 TE WI 27 TE WI 40 CG WI 90 CGOperating limitsHeating water supply/return °C Up to 55Water (source) °C +7 to +25PerformanceHeating capacity W10/W35 (kW)1 compressor 8.2 1 13.5 1 16.9 1 21.3 1 26.1 1 23.4 2 49.8 22 compressors - - - - - 44.4 2 91.2 2Coefficient of performance A7/W351 compressor 4.8 1 4.7 1 5.2 1 5.3 1 4.9 1 5.9 2 5.9 22 compressors - - - - - 5.7 2 5.4 2Minimum <strong>heat</strong>ing flow @ internal pressuredifferential (m 3 /h/Pa) 0.75 / 7000 1.3 / 7000 1.6 / 2600 2.0 / 8000 2.4 / 12500 3.5 / 14000 8.0 / 13000Refrigerant: type/total charge weight (kg) R407C / 1.7 R407C / 1.9 R407C / 3.5 R407C / 4.2 R407C / 4.5 R407C / 6.7 R407C / 15Dimensions H x W x L (mm) 1445x650x575 1445x650x575 1445x650x575 1445x650x575 1445x650x575 830x1480x890 830x1480x890Weight (including packaging) (kg) 156 165 187 189 259 309 460Nominal Voltage / fuse rating (V/A) 230 / 16 230 / 25 400 / 16 400 / 20 400 / 20 400 / 35 400 / 63Starting current with soft starter (A) 26 45 28 27 29 26 601Performance standards measured to EN2552Performance standards measured to EN14511LAS 10 MT LAS 15 MT LAS 22 TTOperating LimitsHeating water supply/return °C +10 to +40 +10 to +40 +10 to +40Air °C -10 to +35 -10 to +35 -10 to +35PerformanceHeating capacity (kW)A20/W24 12.1/2.9 16.6/3.5 22.3/4.4Sound pressure level at a distance of 10m dB (A) 45 45 46Refrigerant: type/total charge weight (kg) R407C / 1.5 R407C / 1.6 R407C / 2.5Dimensions H x W x L (mm) 860x127x67 860x127x67 860x127x67Weight (including packaging) (kg) 147 155 162Nominal Voltage / fuse rating (V/A) 230/20 230/25 400/16Starting current with soft starter (A) 33 43 25For additional hydraulic modules please refer to page 54.Technical specification53


Heating andhot watermanifolds<strong>Dimplex</strong> offer a selection of <strong>heat</strong>ing and hot water manifolds, subject to flowrate of the <strong>heat</strong> pump. Please refer to the individual product minimum flowrates which are shown in the technical specification tables.ModelFlow rates(m 3 /h)KPV 25 up to 1.3m 3 /h Compact manifoldEBKPV up to 2.0m 3 /h Extension module for KPV moduleDDV32 up to 2.5m 3 /h Dual differ. pressure less moduleWWM25 up to 2.5m 3 /h Heating circuit / hot water moduleMMH25 up to 2.0m 3 /h Mixed <strong>heat</strong>ing circuit moduleVTB25 up to 2.5m 3 /h Manifold barAdditional manifolds for alternative systemsMMB25 flow rates up to 2.0m 3 /h Bivalent mixing manifoldSST25 Max. of 10m 2 solar panels Solar stationKPV25 / WWM25 / MMH25MMB25EBKPVSST25VTB25DDV3254Technical Heating and specification hot water manifolds


SupportInformationAs well as the most extensive range of <strong>heat</strong> <strong>pumps</strong> in the UK, <strong>Dimplex</strong> also hasa wealth of support information available.Case Studies<strong>Dimplex</strong> <strong>heat</strong> <strong>pumps</strong> have been installed in a wide variety of installations across domestic andcommercial applications from private and social housing developments, through to schools,hospitals, nursing homes and retail parks. To view a selection of case studies, simply visit therenewables section of our website.TrainingGround SourceHeat PumpInstallerWhether you are an installer looking for new business opportunities or a specifier wishingto understand more about <strong>heat</strong> <strong>pumps</strong>, <strong>Dimplex</strong> can help with a variety of training coursesavailable. If you are an installer with demonstrable competency and experience in plumbingand <strong>heat</strong>ing, you could become a <strong>Dimplex</strong> Accredited Installer for <strong>Dimplex</strong> air and/or groundsource <strong>heat</strong> <strong>pumps</strong>. Our two and three day training courses are available throughout the UKand once you have passed the course, you will enjoy the many benefits associated with thisprogramme. For specifiers, we offer a one day familiarization course and further details of allcourses can be found on our website, or by emailing training@dimplex.co.uk.CPD SeminarsSolarInstaller<strong>Dimplex</strong> are part of the Construction CPD Service and take part in their annual roadshowseminars as well as hosting events ourselves at various venues around the country. Subject tonumbers and timing, we are also able to undertake presentations at client offices. Copies ofcurrent presentations can be found on our website.Planning GuideAir SourceHeat PumpInstallerThis comprehensive technical guide provides all the detailed information a specifier or installerneeds including performance data, system design and other relevant support informationdocumentation. Available as a download on our website, or as a printed document –ordered via our website or by phoning 0845 600 5111.RouteOne Specifier GuidesA series of specifier guides which cover the key issues which relate to low carbon <strong>heat</strong>ingsolutions, including the Code for Sustainable Homes, with practical and detailed examples onhow compliance can and has been achieved.NewslettersIn addition to product based literature, we also produce a regular newsletter –EcoTalk which covers all the latest news and views of the industry.Electronic supportIn addition to web based product information, we also have links to more detailed informationon <strong>Dimplex</strong> <strong>heat</strong> <strong>pumps</strong> to assist those involved in the specification or installation.• Individual Product Data Sheets• On-line Cost CalculatorThis powerful tool helps to select the correct <strong>heat</strong> pump for your application and compare therunning costs with other types of <strong>heat</strong>ing systems.• On-line Hydraulic Integration DiagramsAids system design and installation by creating customised hydraulic schematic diagrams of the<strong>heat</strong> pump system for your project.Please visit the renewables section of www.dimplex.co.uk for full details.Support information55


<strong>Dimplex</strong> Heat Pumps – Always the right solutionCERTIFIED QUALITYMaximum operational reliability of all <strong>Dimplex</strong> <strong>heat</strong> <strong>pumps</strong> is ensuredat all times due to continuous quality assurance during productionand quality certification to EN ISO 9001. The international <strong>heat</strong> pumpquality label for <strong>heat</strong> pump <strong>heat</strong>ing systems guarantees highest safetyand quality standards.The tests conducted by recognised testing institutesprovide comparability of results, ensure compliance with standardsand guarantee an extensive after-sales network with at least 10-yearspare parts availability. <strong>Dimplex</strong> is also a Member of the Heat PumpAssociation [HPA], the Ground Source Heat Pump Association [GSHPA],BEAMA Low Carbon and the European Heat Pump Association.THE DIMPLEX RANGE<strong>Dimplex</strong> offers the widest range of electric space and water <strong>heat</strong>ing products in the world– nearly 400 – to meet almost any <strong>heat</strong>ing need. In addition to this publication, we havea wide range of brochures for both domestic and commercial applications.Choose from:Specifications<strong>Dimplex</strong> policy is one of continuous improvement; the Company therefore reserves theright to alter specifications without notice. Although every care has been taken in theSolarhot waterbrochureWater <strong>heat</strong>ingbrochureCommercialbrochurereproduction of product finishes in this brochure, the colour photographs should betaken only as a guide. The information contained in this brochure is correct at the timeof printing.CE MarkProducts carrying the CE mark comply with European safety standardsand the European Standard for electro-magnetic compatibility.RangebrochureFires brochurePortablesbrochureGeneral Information - Useful ContactsGreat BritainTel: 0845 600 5111Fax: 01489 773050Email: customer.services@dimplex.co.ukWebsite: www.dimplex.co.ukNorthern IrelandTel: 028 3833 7317Fax: 028 3835 0208Email: info@glendimplexni.co.ukWebsite: www.glendimplexni.co.ukLow Carbon Buildings Programme Phase 2Grant InformationGreat BritainTel: 0800 023 2243Fax: 01489 773061Email: lcbp@dimplex.co.ukWebsite: www.dimplex.co.ukNorthern IrelandTel: 028 3833 7317Fax: 028 3835 0208Email: info@glendimplexni.co.ukWebsite: www.glendimplexni.co.ukRepublic of IrelandTel: No. 01 8424833Fax: No. 01 8424705Email: sales@dimpco.ieWebsite: www.dimpco.ie© <strong>Dimplex</strong> UK LimitedAll rights reserved. Material contained in thispublication may not be reproduced in wholeor in part, without prior permission in writingfrom <strong>Dimplex</strong> UK Limited.<strong>Dimplex</strong>, Millbrook House, Grange Drive, Hedge End, Southampton, SO30 2DF.For Northern Ireland, contact Glen <strong>Dimplex</strong> N I Limited, 5 Charlestown Avenue, Charlestown Industrial Estate, Charlestown Road, Craigavon, BT63 5ZFFor Republic of Ireland, contact Dimpco Ltd, Airport Road, Cloghran, County DublinDesigned and produced by CCA Marketing Limited, Christchurch (Bournemouth). www.cca-marketing.comD1381/0209