12.07.2015 Views

Dimplex heat pumps - WF Senate

Dimplex heat pumps - WF Senate

Dimplex heat pumps - WF Senate

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Reversible air source <strong>heat</strong> <strong>pumps</strong>Indoor installationModels available:8kW single phase, integrated (LI 8 MEKR)11kW single phase (LI 11 MER)11kW three phase with <strong>heat</strong> recovery (LI 11 TER+)16kW three phase with <strong>heat</strong> recovery (LI 16 TER+)Outdoor installationModels available:11kW single phase (LA 11 MSR)16kW three phase (LA 16 ASR)6-10kW single phase (LA 6-10 MR)12-16kW three phase (LA 12-16 MR)Indoor InstallationLI TER+Outdoor InstallationLA MSR / ASRLA MRReversible <strong>heat</strong> <strong>pumps</strong> for active coolingIn winter the <strong>heat</strong> pump functions as an energy efficient <strong>heat</strong>ingdevice and extracts the required energy from the environment. Byreversing this process the <strong>heat</strong> pump can be operated to providecooling, extracting <strong>heat</strong> from the building and transferring this to theenvironment via the <strong>heat</strong> pump refrigerant and compressor.Waste <strong>heat</strong> recovery makes it possible to also produce domestic hotwater extremely efficiently during the cooling process, while returningwaste <strong>heat</strong> to the ground (using a ground source <strong>heat</strong> pump)effectively stores the energy for use later in the year when needed for<strong>heat</strong>ing. The entire system is controlled by the <strong>heat</strong> pump manager.Passive cooling with borehole <strong>heat</strong> exchangers or groundwater.Deeper ground layers have constant temperature levels of around10°C all year round. This allows ground source <strong>heat</strong> <strong>pumps</strong> installedwith vertical borehole collectors to be used to provide ‘passive’cooling, by transferring excess <strong>heat</strong> from the building to the groundvia the collector in the summer months.This is achieved with the addition of a retro-fittable passivecooling unit, controlled by an additional cooling controller, whichcommunicates with the <strong>heat</strong> pump manager to enable a combinationof <strong>heat</strong>ing and ‘comfort’ cooling in a single system.Domestic hot water can still be provided in parallel to the coolingoperation as the <strong>heat</strong> pump compressor is not active in the passivecooling mode.Depending on the type of <strong>heat</strong>ing system installed in the building,cooling can be provided in one of two ways:Silent (active) cooling via surface <strong>heat</strong>ing systemsIn summer, the <strong>heat</strong>ing surfaces in floors, walls and ceilings areactivated for cooling by passing cooled water through them. Largecooled surfaces cool the rooms to a comfortable temperature withoutdraughts or air movement.Dynamic cooling via fan convectorsIntegrated ventilators guide the indoor air to a <strong>heat</strong> exchanger, which<strong>heat</strong>s or cools the air according to need. Multi-level controllable airrecirculation guarantees short response times and high transmissioncapacities.Reversible ground source <strong>heat</strong> <strong>pumps</strong>Models available:5-11kW single phase (SI 5-11 TER)30kW three phase with <strong>heat</strong> recovery (SI 30 TER+)75kW three phase with <strong>heat</strong> recovery (SI 75 TER+)SI 75 TER+ SI 30 TER+ SI 5-11 MERPlease see technical specification pages for typical system configuration and accessories.Reversible <strong>heat</strong> <strong>pumps</strong>37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!