12.07.2015 Views

Junior Utility Blowers (DFC, FCUJ, BIUJ, BIUJU5, BIUJU2) - Aerovent

Junior Utility Blowers (DFC, FCUJ, BIUJ, BIUJU5, BIUJU2) - Aerovent

Junior Utility Blowers (DFC, FCUJ, BIUJ, BIUJU5, BIUJU2) - Aerovent

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

PerformanceData<strong>DFC</strong> Direct Drive <strong>Utility</strong> <strong>Blowers</strong>MODEL MOTOR1/8" SP 1/4" SP 3/8" SP 1/2" SP 5/8" SP 3/4" SP 1" SPRPMNO. HP CFM OV CFM OV CFM OV CFM OV CFM OV CFM OV CFM OV<strong>DFC</strong>60L 1/6 1150 324 1466 254 1149 — — — — — — — — — —<strong>DFC</strong>60H 1/6 1750 545 2466 506 2290 464 2100 421 1905 362 1638 292 1321 — —<strong>DFC</strong>75L 1/6 1150 668 2264 586 1986 516 1749 447 1515 — — — — — —<strong>DFC</strong>75M 1/3 1750 — — — — — — — — 874 2963 828 2807 741 2512<strong>DFC</strong>75H 1/2 1750 1085 3678 1033 3502 978 3315 923 3129 874 2963 828 2807 741 2512<strong>DFC</strong>90L 1/3 1150 — — 1216 2916 1129 2707 1042 2499 946 2269 802 1923 — —<strong>DFC</strong>90M 1/2 1150 1300 3118 1216 2916 1129 2707 1042 2499 946 2269 802 1923 — —<strong>DFC</strong>90J 1 1 ⁄2 1750 2048 4911 1994 4782 1940 4652 1886 4523 1830 4388 1772 4249 1657 3974<strong>DFC</strong>105L 1 1150 2127 3648 2036 3492 1945 3336 1855 3182 1766 3029 1681 2883 1484 2545MODEL MOTOR1" SP 1 1 ⁄4" SP 1 1 ⁄2" SP 1 3 ⁄4" SPRPMNO. HP CFM OV CFM OV CFM OV CFM OV<strong>DFC</strong>90H 1 1750 — — 1543 3700 1408 3376 1205 2890<strong>DFC</strong>90J 1 1 ⁄2 1750 1657 3974 1543 3700 1408 3376 1205 2890Model <strong>DFC</strong> is not licensed to bear the AMCA Seal.<strong>BIUJ</strong>/<strong>BIUJ</strong>U5/<strong>BIUJ</strong>U2 SWSI Belt Driven <strong>Utility</strong> Blower | Size 90Wheel Diameter: 10 1 ⁄2" Tip Speed, FPM: 2.75 x RPM Outlet Area: 0.653 ft 2 Fan Efficiency Grade: FEG67CFM OV1/8" SP 1/4" SP 1/2" SP 3/4" SP 1" SP 1 1 ⁄2" SP 2" SP 3" SP 4" SPRPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP261 400 829 0.01 970 0.02 1190 0.04327 500 964 0.02 1088 0.03 1305 0.05 1470 0.07 1626 0.09392 600 1095 0.03 1220 0.04 1409 0.06 1584 0.09 1722 0.12457 700 1232 0.04 1352 0.05 1527 0.08 1688 0.11 1836 0.14 2069 0.20522 800 1374 0.05 1483 0.07 1659 0.10 1799 0.13 1940 0.17 2184 0.24 2380 0.30588 900 1521 0.07 1618 0.09 1794 0.13 1927 0.16 2051 0.20 2295 0.28 2495 0.35 2840 0.50653 1000 1668 0.10 1756 0.11 1926 0.16 2059 0.20 2173 0.23 2399 0.32 2608 0.41 2938 0.57 3251 0.75718 1100 1817 0.12 1898 0.14 2056 0.19 2193 0.23 2304 0.28 2508 0.36 2712 0.46 3052 0.65 3334 0.82784 1200 1970 0.16 2044 0.18 2190 0.22 2327 0.28 2440 0.32 2631 0.42 2819 0.52 3168 0.73 3444 0.92849 1300 2121 0.19 2190 0.22 2325 0.27 2457 0.32 2573 0.38 2760 0.48 2932 0.58 3274 0.81 3560 1.03914 1400 2274 0.24 2338 0.26 2463 0.31 2588 0.37 2705 0.43 2893 0.54 3055 0.65 3377 0.89 3673 1.14980 1500 2429 0.29 2489 0.32 2606 0.37 2723 0.43 2837 0.49 3029 0.62 3186 0.73 3485 0.981045 1600 2582 0.35 2639 0.38 2749 0.43 2858 0.49 2968 0.56 3162 0.70 3319 0.82 3600 1.071110 1700 2736 0.41 2789 0.44 2894 0.50 2996 0.57 3100 0.64 3294 0.78 3453 0.921175 1800 2890 0.49 2940 0.52 3040 0.58 3137 0.65 3234 0.72 3424 0.87 3587 1.021241 1900 3046 0.57 3094 0.60 3189 0.67 3282 0.74 3373 0.81 3556 0.97<strong>BIUJ</strong>/<strong>BIUJ</strong>U5/<strong>BIUJ</strong>U2 SWSI Belt Driven <strong>Utility</strong> Blower | Size 105Wheel Diameter: 10 1 ⁄2" Tip Speed, FPM: 2.75 x RPM Outlet Area: 0.653 ft 2 Fan Efficiency Grade: FEG75CFM OV1/4" SP 1/2" SP 3/4" SP 1" SP 1 1 ⁄2" SP 2" SP 3" SP 4" SP 5" SPRPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP327 500 901 0.02 1151 0.04 1360 0.07392 600 980 0.03 1203 0.05 1403 0.08 1579 0.11457 700 1063 0.04 1267 0.06 1453 0.09 1623 0.12 1920 0.19522 800 1149 0.05 1346 0.08 1512 0.10 1674 0.14 1961 0.21 2214 0.29588 900 1239 0.06 1429 0.09 1585 0.12 1732 0.15 2009 0.24 2255 0.32653 1000 1330 0.07 1512 0.11 1665 0.14 1800 0.18 2061 0.26 2300 0.35 2720 0.55784 1200 1522 0.11 1686 0.14 1831 0.19 1961 0.23 2187 0.32 2405 0.41 2806 0.63 3158 0.87 3477 1.12914 1400 1721 0.15 1868 0.20 2003 0.24 2126 0.30 2343 0.40 2535 0.49 2907 0.72 3246 0.98 3555 1.251045 1600 1927 0.21 2058 0.26 2183 0.31 2298 0.37 2509 0.49 2693 0.60 3025 0.83 3348 1.10 3647 1.401175 1800 2135 0.29 2253 0.34 2367 0.40 2476 0.45 2676 0.59 2857 0.72 3169 0.97 3462 1.241306 2000 2347 0.38 2455 0.44 2559 0.50 2661 0.57 2850 0.70 3024 0.85 3331 1.14 3600 1.411437 2200 2562 0.49 2660 0.56 2756 0.63 2850 0.70 3030 0.83 3196 0.99 3496 1.321567 2400 2776 0.62 2867 0.70 2956 0.77 3043 0.85 3213 1.00 3371 1.15 3662 1.511698 2600 2994 0.77 3078 0.86 3160 0.94 3241 1.02 3400 1.18 3553 1.341828 2800 3210 0.95 3289 1.04 3366 1.13 3442 1.22 3591 1.391959 3000 3429 1.15 3503 1.25 3575 1.35 3647 1.44Performance certified is for installation Type B & D: Free or ducted inlet, ducted outlet.Power rating (bhp) does not include transmission losses.Performance ratings do not include the effects of appurtenances (accessories).Underlined numbers indicate maximum static efficiency.4<strong>Aerovent</strong> Catalog 765

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!