12.07.2015 Views

Lighting Electronics | 2007/08 - National Lamps and Components

Lighting Electronics | 2007/08 - National Lamps and Components

Lighting Electronics | 2007/08 - National Lamps and Components

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

BL-HP 1x18 T8 MS3Article Number: 09 7113BL-HP 1x36W T8 MS3Article Number: 09 7114T8Product Highlights• Very compact housing: height only 21 mm, length only 280 mm• Active harmonic wave filter enables constant power output across awide input range• Reduced power losses, decreased self-heating of the ballast• Flicker-free during operation• No irritating noise• Lamp warm start <strong>and</strong> operation acc. to EN 60929• Fast <strong>and</strong> smooth lamp warm start within 1 second• Alternative fixing via side-installation.• 100 % light independent from mains voltage fluctuations• Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• Suitable for emergency light fittings in accordance with VDE 01<strong>08</strong>• Universal terminal blocks for manual <strong>and</strong> automatic lamp wiring• EOL (end of life) shut down of ballast at lamp end of life or defect• Automatic restart once the lamp has been changedProduct Highlights• Very compact housing: height only 21 mm, length only 280 mm• Active harmonic wave filter enables constant power output across awide input range• Reduced power losses, decreased self-heating of the ballast• Flicker-free during operation• No irritating noise• Lamp warm start <strong>and</strong> operation acc. to EN 60929• Fast <strong>and</strong> smooth lamp warm start within 1 second• Alternative fixing via side-installation.• 100 % light independent from mains voltage fluctuations• Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• Suitable for emergency light fittings in accordance with VDE 01<strong>08</strong>• Universal terminal blocks for manual <strong>and</strong> automatic lamp wiring• EOL (end of life) shut down of ballast at lamp end of life or defect• Automatic restart once the lamp has been changedAdditional Product HighlightsAdditional Product HighlightsHVPHVPEN 60929 EN 61000-3-2EN 60929 EN 61000-3-2Technical DataTechnical DataLampT8LampT8PowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark18W220 - 240 V~0/50...60 Hz176...276 V-20°C...+55 °C1A2≥ 0,96 c280 x 30 x 21 mmca. 200 gENEC, VDEPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark36W220 - 240 V~0/50...60 Hz176...276 V-20°C...+55 °C1A2≥ 0,98 c280 x 30 x 21 mmca. 200 gENEC, VDET8 ECGno dimTechnical DrawingTechnical Drawing2700,32700,34,2 304,25,42700,34,20,394,24,2 304,25,42704,22112,8994,22112,8928028072Subject to technical modification

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!