12.07.2015 Views

The Safety Handbook ABB Jokab - Automation Systems and Controls

The Safety Handbook ABB Jokab - Automation Systems and Controls

The Safety Handbook ABB Jokab - Automation Systems and Controls

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Pluto with a safety busPluto models with a safety bus controls <strong>and</strong> monitors safety for dispersed systems– large aswell as small systems.Profibus DPDeviceNetCANopenProfinetEthernet/IPModbus TCP20/46 I/OGatewayfor twoway bus communicationbetweenPluto <strong>and</strong> othercontrolsystems.HMIA HMI-terminal iseasy to connect toone or more Plutosthrough the Modbuscontact.Absolutgivare8 single- or multiturnabsolute encoders can beconnected.Pluto ManagerA free of charge softwareis available on our website.Pluto versions with bus have the same properties as single-Pluto unlike bus communication. With the help of the Plutobusnetworks can be created with multiple Plutos in interaction.Gateways can be connected to the Pluto bus forcommunication with other systems. <strong>The</strong> gateway modelsGATE D2 <strong>and</strong> C2 can also be used as an extension of thebus cable to extend the Pluto network. <strong>The</strong> fact that Pluto isan All-master system means that each Pluto device controlsits outputs locally, while it is just as easy to read the inputsof other Pluto-units as it is to read its own. It is also easy toboth read <strong>and</strong> write to global memory locations availableacross the Pluto bus. <strong>The</strong> PLC program is created usingthe Pluto Manager freeware <strong>and</strong> is distributed to all Plutounits. You can also connect speed <strong>and</strong> position sensorsvia the Pluto bus.Current monitoring (Pluto A20 only)Pluto A20 can monitor the current through the IQ16 <strong>and</strong>IQ17 outputs. <strong>The</strong> function is designed for, but not limitedto, ensuring that the muting lamps are working. <strong>The</strong>hardware for current monitoring is not designed with individualredundancy, which means that the function must beused dynamically if it is to be used in a safety function. Thismeans that the current must be read <strong>and</strong> evaluated bothwhen the output is enabled <strong>and</strong> disabled.2:12<strong>ABB</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!