12.07.2015 Views

Download you PDF version! - Sontay

Download you PDF version! - Sontay

Download you PDF version! - Sontay

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

RE-PR11.5, 3 and 6kW, Single-phase ControllersThis range of triac control assemblies providefull seamless control of single phase electricheating loads.The controllers incorporate a temperature trip,automatic reset, integral semi-conductor fusesand heatsink.FEATURES■■0-10Vdc or 0-5Vdc control input■■Over temperature protection with auto reset■■No additional heatsinks required■■No external 24V supply required■■No external RFI filters requiredPart code Description Current ratingRE-PR1-F-1.5 1.5kW Controller 6.3ARE-PR1-F-3 3kW Controller 12.5ARE-PR1-F-6 6kW Controller 25ASPECIFICATIONInput signal: 0-5Vdc or 0-10VdcSupply:230Vac RMS ±10%, 50/60HzOver temp: Trip-in temp. @ 90°C (194°F) ±1°C (±1.8°F)Trip-out temp. @ 85°C (185°F) ±1°C (±1.8°F)Fault condition: Over temp. LED flashes in 0.5 sec pulse burstsLoss of signal LED flashes in 1 sec pulse burstsAmbient temp: 65°C (149°F) – maximum operationalDimensions: RE-PR1-F-1.5 112 x 95 x 75mm (4.41 x 3.74 x 2.95”)RE-PR1-F-3 112 x 95 x 75mm (4.41 x 3.74 x 2.95”)RE-PR1-F-6 112 x 95 x 85mm (4.41 x 3.74 x 3.35”)Weights:RE-PR1-F-1.5 - 280g (0.62 lb), RE-PR1-F-3 - 280g (0.62 lb)RE-PR1-F-6 - 700g (1.54 lb)Part codeRE-PR1-F15102RE-PR1-F15103RE-PR1-F11307RE-PR1-F-6-GDData sheet: RE-PR1-F.pdfDescriptionAccessories1.5kW Replacement fuse3kW Replacement fuse6kW Replacement fuseReplacement 6kW guardRE-PR312 and 18kW, 3-phase ControllersThe RE-PR3-DIN-xx range of thyristor stacksprovides full seamless control of 415V supplyloads. They incorporate a temperature trip,automatic reset, alarm output, LED indication(output on) and heatsink.FEATURES■■0-10Vdc control input■■Over temperature protection with auto reset■■No additional heatsinks requiredPart code Description Current ratingRE-PR3-DIN-12 12kW Controller 16.7A per phaseRE-PR3-DIN-18 18kW Controller 25A per phaseData sheet: RE-PR3-DIN.pdfSPECIFICATIONInput signal: 0-10VdcExternal supply: (control) 24Vac/dc ±10%, 50HzSupply:(load) 3-Phase, 400Vac RMS ±10%, 50HzFault condition: 24Vac/dc (as power supply)24V alarm terminal normally present, drops to 0V in theevent of over-temp. or loss of external power supplyLED indication: T1 & T3 LED pulse when output is ‘ON’Mounting:DIN-railAmbient temp: 40°C (104°F) – max. operationalDimensions: RE-PR3-DIN-12 217 x 92 x 85mm (8.54 x 3.62 x 3.35”)RE-PR3-DIN-18 217 x 92 x 107mm (8.54 x 3.62 x 4.21”)Weights: RE-PR3-DIN-12 600g (1.32 lb)RE-PR3-DIN-18 960g (2.12 lb)RE-PR3-E27, 36, 54, 86 and 105 kW, 3-phase ControllersSPECIFICATIONInput signal:Supply:These thyristor control assemblies provide fullseamless control of 3-phase resistive loads ofup to 27, 36, 54, and 105 kW. The controllersincorporate a temperature trip, automaticreset, alarm output, LED indication (outputon) and heatsink.FEATURES■■0-5Vdc, 0-10Vdc or 4-20mA control input■■Over temperature protection with auto reset■■No additional heatsinks required■■No external 24V supply required0-5Vdc, 0-10Vdc or 4-20mA(control) 24Vac/dc ±10% (by dipswitch)(load) 3-Phase, 400Vac RMS ±10%, 50/60HzOver temp:Trip-in temp. @ 90°C (194°F) ±1°C (±1.8°F)Trip-out temp. @ 85°C (185°F) ±1°C (±1.8°F)Fault condition: Relay rated at 230Vac @ 8AFault status:Phase loss – LED flashes in 1.5 sec pulse burstsSensor loss – LED flashes in 0.5 sec pulse burstsAmbient temp: 65°C (149°F) - maximum operationalMounting:PanelDimensions: RE-PR3-E -27 150 x 240 x 100mm (5.91 x 9.45 x 3.94”)-36 205 x 155 x 120mm (8.07 x 6.10 x 4.72”)-54 250 x 155 x 120mm (9.84 x 6.10 x 4.72”)-86 & 105 340 x 232 x 124mm (13.39 x 9.13 x 4.88”)Weights: RE-PR3-E -27 3.0kg (6.61 lb)-36 3.6kg (7.94 lb)-54 3.6kg (7.94 lb)-86 & 105 6.6kg (14.55 lb)Part code Description Current ratingRE-PR3-E-27 27 kW Controller 38A per phaseRE-PR3-E-36 36 kW Controller 50A per phaseRE-PR3-E-54 54 kW Controller 75A per phaseRE-PR3-E-86 86 kW Controller 120A per phaseRE-PR3-E-105 105 kW Controller 146A per phaseNote: Larger sizes are available on request.Part code DescriptionAccessoriesRE-PR3-F11310 27kW Replacement fuseRE-PR3-F11511 36kW Replacement fuseRE-PR3-F11513 54kW Replacement fuseRE-PR3-F11606 86kW Replacement fuseRE-PR3-F11610 105kW Replacement fuseData sheets: RE-PR3-E-27.pdf ∙ RE-PR3-E-36&54.pdf ∙ RE-PR3-E-86&105.pdf& Interfaces Pressure Relative Humidity Wireless Devices Temperature Valves & ActuatorsUK Tel. +44 (0) 1732 861200 · Int. Tel. +44 (0) 1732 861225 · UK Fax +44 (0) 1732 861201 · Int. Fax +44 (0) 1732 86122641

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!