12.07.2015 Views

Download you PDF version! - Sontay

Download you PDF version! - Sontay

Download you PDF version! - Sontay

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

VS-PSGas Electro-hydraulic ValvesA range of Class ‘A’ 2-port, 2-positionoil-filled hydraulic gas valves for use insecuring, limiting, shutting off andreleasing gas supplies to atmosphericboilers, gas burners and similar equipment.Units are fitted with a closed position switchas standard. A manual reset switch option isavailable.Part code DescriptionScrewed ValvesVS-PS6683 1½” BSP Hydraulic Gas Valve c/w CPIVS-PS6684 2” BSP "VS-PS6685 2½” BSP "VS-PS6686 3” BSP "Flanged ValvesVS-PS6687F 4” BSP Hydraulic Gas Valve c/w CPIVS-PS6689F 6” BSP "SPECIFICATIONOperating voltage: 240Vac +10% –15% @ 50/60HzOperating pressure: 200mbar max.Closure time:Max. 1 secondBody material:Die cast aluminiumMedia:Non-corrosive gases – Air or oil(up to 200s Redwood No.1)Pipework connections: Up to 3” Screwed BSP female4” and over Flanged to PN16Power consumption: Opening 200VAFully open 18VASwitch rating:250Vac or 30Vdc @ 5(2)AAmbient temperature: –15 to +60°C (5 to 140°F)Protection:IP54Weight:60kg max. (32 lb)Part codeVS-PS-MRSData sheet: VS-PS.pdfDescriptionAccessoryManual reset switchCondensation SensingCHILLED BEAM APPLICATION (WD-cps)A condensation prevention sensorcan give early indication of theonset of condensation so thatpreventative action can be taken.Chilled beam systemscan cause indoor rain.WD-CPSCondensation Prevention Sensor<strong>Sontay</strong>’s condensation prevention sensor hasbeen designed to provide a switched outputsignal to prevent the onset of condensation onchilled surfaces suchas chilled beams.The detector measures the temperaturecompensated RH and surface temperatureof the chilled surface and calculates the dewpoint temperature. This is compared to anadjustable setpoint to provide either a currentoutput or VFC switched output.FEATURES■■Reliable and accurate switching■■VFC or current output■■Quick and simple to installSPECIFICATIONOutput: Current mode (dry 12 mA)VFC mode SPDT contact, 240Vac @ 1A resistiveSupply voltage: 24Vdc ±5% or 24Vac ±10%Cable:Low smoke and fumeDimensions: 70 x 48 x 30mm (2.76 x 1.89 x 1.18”)Weight:80g (0.18 lb)Part code DescriptionWD-CPS Condensation Detector - 2m (6.56 ft) leadWD-CPS-5M Condensation Detector - 5m (16.4 ft) leadData sheet: WD-CPS.pdfAir & Water Flow Air Quality & Gas Detection Controllers Input / Output Modules Water & Energy Metering Peripherals70www.sontay.com · Email sales@sontay.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!