Installation Manual2dd2.5 m max.3% minimumslope2dd2.5 m.max.3% minimumslopeFLUE EXHAUST DIRECTLYINTO A DUCT (CHIMNEY)OR COLLECTIVE BRANCH-TYPE FLUEVERTICAL EXHAUSTOpen chamber modelSuctionopeningFig. 1A maximum of 3 changes ofdirection are allowed.Keep to the distances andangles shown in the diagram.2dd1 m min.3% minimumslope1.5 m min.2dmin.2dd1 m min.3% minimumslopeFLUE EXHAUST DIRECTLYTO OUTSIDEVERTICAL EXHAUSTOpen chamber modelA maximum of 2 changes ofdirection are allowed includingthe first connection to theboiler.Keep to the distances andangles shown in the diagramFig. 2For the flue exhaust from multiple superimposed type "B" gas boilers with natural draught into newly <strong>install</strong>ed collective flues(CCR) with natural draught, follow the directions set out in the UNI 10640 standard.It should be noted that these type of flues do not apply in the case of boilers equipped with mechanical means of flue exhaust.For the FLUE EXHAUST from multiple combined type "C" room sealed gas boilers equipped with exhaust fans into singlechimneycollective flues with natural draft or multiple combined flues, follow the directions set out in the UNI 10640 standard.CONNECTION OF FLUE PIPESAll boilers must be connected to a duct for discharging the burnt gasses; the section of this duct must not be less than thediameter of the pipe coming out of the boiler and must be sealed airtight so that no burnt gasses can leak out. There must be nolong horizontal sections or abrupt deviations along its length (see fig. 1-2).• For type B open combustion circuit boilers;• connect the boiler to the chimney using a ∅ 130 link.• For type C12 sealed combustion circuit boilers;• KIT A - COAXIAL EXHAUST connect using the ∅ 100 - 60 double elbow and 2 coaxial pipes; ∅ 60 for EXHAUST ofcombustion gasses - ∅ 100 for air INTAKE.• For type C32 sealed combustion circuit boilers;• KIT B – TWIN PIPE SYSTEM connect using 2 sections with a ∅ 80 elbow for the EXHAUST of combustion gasses - ∅ 80for air INTAKE.N.B.: FLUE KITS are supplied in a separate box.Wall Hung Boiler with D.H.W. Storage Cylinder Low Nox – Cod. 99881NA – July 20015

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!