Installation ManualTECHNICAL DATADIFFERENTIAL AIR PRESSURE SWITCH FOR FAN CONTROLTo guarantee maximum safety in flue exhaust, a differential pressure switch is<strong>install</strong>ed on room-sealed boilers and on forced draught boilers. This pressureswitch automatically controls perfect functioning of the fan and the passage ofboth external air and exhaust flue pipes.Natural draught boilers are equipped with a device (see fig. 1) to control correctexhaust of combustion gases. This device guarantees maximum safety ofoperation if the flue should become partially or totally blocked, or if its section isnot suitable for exhaust of combustion gases.Before resetting the device, check the exhaust flue section and make sure thereare no. blockages obstructing the correct escape of fumes.ELECTRICAL CONNECTION1FLUE SAFETY THERMOSTAT2 Fig. 1N.B. It is strictly forbidden to tamper with the device.RESETTING: before resetting the thermostat, carry out the followingoperations:• turn off the main power supply switch;• turn the summer-winter selector switch to the OFF position, detach theelectrical connection (1) on the flue safety thermostat (see fig.1), pressthe button (2) between the two electrical contacts and then attach theelectrical connection 1 again.;• turn the main power supply switch on again and set the summer/winterselector switch to the position required.DIVERTER VALVE VC 6012MG6000The diverter valve is the device which controls the boiler switching fromcentral heating to d.h. water circuit and vice versa. The diverter valve is fittedwith a manual command lever C (fig. 3) which, when set on the top position,towards the valve head, allows the boiler operating on the domestic hot watercircuit while, when set on the low position, the boiler operates on the centralheating circuit.When the C lever is set on the central position, it allows the actuator onmidway.In this position, to be used only in case of motor failure or damage, bothcentral heating and domestic hot water ports are open and both domestic hotwater and central heating circuits are operating.To restore the initial position, separate the actuator and the valve bodyfollowing instructions from no.1 to no.4 (see fig.2).To separate the motor from the valve body proceed as follows (fig.2):1. Press button A under the motor.2. Simultaneously keep the A button pressed and turn the actuator counterclockwise;3. Lift off the motor4. To disconnect the power supply cable press the B tap located on the pin C.D.H. WATER SETTINGRAMIRE P.C. BOARDM5 TERMINALlight-bluebrownFig. 2blackFig. 3CENTRAL HEATING SETTINGFig. 4Light-blueBrownBlack- Common- D.H. Water- Central HeatingSee fig. 4 to perform the electrical wiring of the diverter valve to the main printed circuit board.DOMESTIC HOT WATER PRODUCTIONThe boilers are designed and built for the production of domestic hot water with a 25 lt. capacity storage tank. One advantage ofthis system is the amount of water immediately available, thanks to the large exchanger surface of the coil inside the boilerwhich allows different services to be used simultaneously.As well as the use of a porcelain treated glass coating on both the coil and the internal boiler surface to guarantee high levels ofhygiene, the inside of the boiler also has a magnesium anode which, in the event of galvanic currents, preserves it fromcorrosion to ensure it a longer working life.Wall Hung Boiler with D.H.W. Storage Cylinder Low Nox – Cod. 99881NA – July 200116

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!