12.07.2015 Views

RMAS- RMA install - Portsdean Technical

RMAS- RMA install - Portsdean Technical

RMAS- RMA install - Portsdean Technical

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installation ManualELECTRICAL CONNECTION FOROPEN COMBUSTION CHAMBER ELECTRONIC IGNITION BOILER – mod. <strong>RMA</strong> 24 ERAMIRE 3 CIRCUIT BOARD STANDARD ON ALL MODELSN.B. M1 CONNECTOR OF THE RAVI 2CIRCUIT BOARD MUST BE CONNECTED TOTHE M11 CONNECTOR OF THE RAMIRE3CIRCUIT BOARD.TIME CLOCKWiring diagram5 4 3 2 1redyellowbluebrown44434248474645R1541R57R61R54IC3R355857 CM156RLA55545352515049M11J11R63FA1R55J6C24+M9J17D4IC4P2RL4-RVJ10+RISC. M13C2559B A6061 CM3R34J21J12J7T4R21R42R58R41R22R43C26+R32C13R31IC2R37+ IC1R16C14R39R62+ R38J20C5J16RS1+R17J9C6C8R49C7R47+C3R48GPLD10D11R36D12METR18R24R23R53SECONDARIOR56C15R40R33PRIMARIOD7D6C9C20R60R59C19C21TR1D8D5PTC1C22+C23R52M6J4M2R51C10C12R201321 20P4RLAR13J26 M3 512 11 10 9 8 74 3 219R5018R12J317R29D3P5T. RIS+ +1615 14M4RL3-RT RL1-RP22T3P3M. RISR25+D1R30R26T1R28J1J13J18FUSE 12AFP1 SAN.R27M5RL2-RSJ5T2+3638402324D2626364M14R5R225262728J4CM4M101M1M12353739J1529M73031323334M8TA OR N LRAVI IIJ3J2D24 3 2 18765M1LED1LED2 LED3 LED4 LED5 LED6LED7LED8LED9LED10LED11RAVI 2 CIRCUIT BOARD-ELECTRONIC TEMPERATURE INDICATOR WITH SELF-DIAGNOSTICWIRING OF COMPONENTS BY MEANS OF CONNECTORS1 2 3 4M11514M422 23 24M516 17 18 19 20 21M6M2IGCYL7R8CYCXNNET FILTERATTENTION:IGNITIONELECTRODE12 11 10 9 8blue9 10 11 12 13brownELECTRONIC IGNITION S4565A20TSTERMINAL BLOCKLB7 6 5 4blackLlight-bluebrownNPSlight-bluePUMPbrownPOPTIONALP.C.B.INTERFACEREMOTElight-blueL Nm1brown3 62 51 43 WAY DIVERTORVALVE8 7m3blackm2RL1blackred/blackbrownbrown3132black33blackblack34blackblackV Z 5+ 4-HEATINGSENSOR10000 - 25°CM810000 - 25°CD.H.WATERSENSORorange25E.I26blackorange2728blackFA148 47 46 45 44bluebrownblackTFGAS VALVEPRESSUREMODULATOR3 C 2brownblackblueback43black42black41M.F.WATERPRESSURESWITCHM9N.B.: IN CASE OF REMOTE CONTROL INSTALLATION, FORCORRECT OPERATION, REMOVE LINK BETWEEN TERMINALS TA-ORON TERMINAL BLOCK, AND SET SUMMER-WINTER SWITCH OFCONTROL PANEL ON SUMMER POSITION.CHECK THE POSITION OF M10 BEFORE INSERTING IT.REMOTECONTROL00.0OR TAOUT-DOORREMOTE SENSOR00.0 2 1 M1Wall Hung Boiler with D.H.W. Storage Cylinder Low Nox – Cod. 99881NA – July 200122

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!