12.07.2015 Views

RMAS- RMA install - Portsdean Technical

RMAS- RMA install - Portsdean Technical

RMAS- RMA install - Portsdean Technical

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installation ManualELECTRICAL CONNECTION FORROOM SEALED COMBUSTION CHAMBER ELECTRONIC IGNITION BOILER – mod. <strong><strong>RMA</strong>S</strong> 24 ERAMIRE 3 CIRCUIT BOARD STANDARD ON ALL MODELSN.B. M1 CONNECTOR OF THE RAVI 2CIRCUIT BOARD MUST BE CONNECTED TOTHE M11 CONNECTOR OF THE RAMIRE 3CIRCUIT BOARD.TIME CLOCKWiring diagram5 4redyellow321bluebrownR54C23J3M1IC3R52 21 20 19 18 17 16FUSE 12AFM615 14R3558R51M457 CM1RL3-RTRL1-RP2256RLA55M12545323PTC1522551J4J2J1242650D7274928M11D6M5J11TR1 +C24C22RL2-RS29+IC4M7P2RL4-RV D3 D1 R27 T230J10 RISC.P1 SAN.+M13J4R63C25R29 T3 R25 T159P4 P5 P362B A48 60RLA T. RIS M. RIS63+ + +3161CM364R3447J21M1432J12J54633J7T4J1345R21J1834R42R5844R41R22R43M8C26+ CM443+R32C133542R31IC236R3737+IC13841 R16 C143940R39R62+M9R38J20M10J15C5J16RS1+R17J9C6C8FA1R49C7R47+C3 R12R48R15R57R61R55J6J17D4D9GPLD10D11R36D12METR18R24R23R53SECONDARIOR56C15R40PRIMARIOR33C9C20R60R59C19C21D8D56M2 M3 513 12 11 10 9 8 7 4 3C10C12R20R13R50R30R26R282 1D2R5R2RAVI IIJ3J24 3 2 1D2 8765M1LED1 LED2 LED3 LED4LED5LED6 LED7 LED8 LED9 LED10 LED11IGCYLRCYCXNM1 M4M5 M6FILTRO NET FILTERREDATTENTION:IGNITIONELECTRODE12 11 10 9 8 7 6 5 4bluebrown7 8 9 10 11 12 13 LBELECTRONIC IGNITION S4565A20TERMINAL BLOCKTSblackLLlght-blueNbrownNPSlight-bluebrownPPUMPRAVI 2 CIRCUIT BOARD-ELECTRONIC TEMPERATURE INDICATOR WITH SELF-DIAGNOSTICWIRING OF COMPONENTS BY MEANS OF CONNECTORS1 2 3 415 14 22light-blueOPTIONALP.C.B.INTERFACEREMOTEbrown23321black654m3m124 16 17 18 19 20 213 WAYDIVERTORVALVEm2RL1blackbrown31 32 33 34AAIR PRESS.SWITCH CblackblackblackblackV Z 5+ 4-M810000 - 25°Cred/black8 7 brown25 26 27 28light-blueblacklight-bluebrownbrownorangeblackFANB10000 - 25°CE.IorangeD.H. WATERSENSORblackHEATINGSENSORFA148 47 46 45 44 43bluebrownblackGAS VALVEPRESSUREMODULATOR3 C 2brownbluebackM.F.WATERPRESSURESWITCH42 41blackblackM9M10N.B.: IN CASE OF REMOTE CONTROL INSTALLATION, FORCORRECT OPERATION, REMOVE LINK BETWEEN TERMINALS TA-ORON TERMINAL BLOCK, AND SET SUMMER-WINTER SWITCH OFCONTROL PANEL ON SUMMER POSITION.CHECK THE POSITION OF M10 BEFORE INSERTING IT.-IN+TELSEXTREMOTECONTROL00.000.0OR TAOUT-DOORREMOTE SENSOR2 M1 1Wall Hung Boiler with D.H.W. Storage Cylinder Low Nox – Cod. 99881NA – July 200124

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!