<strong>Advanced</strong> Instruments Inc.7 Spare PartsRecommended spare parts for the <strong>GPR</strong>-<strong>1800</strong><strong>AIS</strong> ppm <strong>Oxygen</strong> Transmitter:Item No.<strong>GPR</strong>-12-333XLT-12-333Descriptionppm <strong>Oxygen</strong> Sensorppm <strong>Oxygen</strong> SensorOther spare parts:Item No.HTR-1004A-1004-2-14A-1016-AB-2762-A-2-14MTR-1011MTR-1014ORNG-1007A-1151-<strong>AIS</strong>-1A-1166-<strong>AIS</strong>-ACA-1166-<strong>AIS</strong>-DCDescriptionHeater Low Power Sensor HousingHousing Sensor Stainless SteelHousing Sensor Bottom Assembly Stainless SteelHousing Sensor Upper Assembly Stainless SteelMeter Digital Panel LCD BacklightMeter Digital Panel LCD Low TemperatureO-ring 3/32 x 1-3/8 x 1-9/16 VitonPCB Assembly Main / DisplayPCB Assembly Interconnection / AC Power SupplyPCB Assembly Interconnection / DC Power Supply8 TroubleshootingSymptom Possible Cause Recommended ActionSlow recovery orAt installation, defective sensorAir leak in sample system connection(s)Abnormality in zero gasDamaged in service - prolonged exposure toair, electrolyte leakSensor nearing end of lifeReplace sensor if recovery unacceptable or O 2reading fails to reach 10% of lowest rangeLeak test the entire sample system: Vary the flowrate, if the O 2 reading changes inversely with thechange in flow rate indicates an air leak - correctsource of leakQualify zero gas (using portable transmitter)Replace sensorReplace sensorHigh O 2 readingafter installingor replacing sensorTransmitter calibrated before sensor stabilizedcaused by:1) Prolonged exposure to ambient air, worseif sensor was unshorted2) Air leak in sample system connection(s)3) Abnormality in zero gasAllow O 2 reading to stabilize before making thespan/calibration adjustmentContinue purge with zero gasLeak test the entire sample system (above)Qualify zero gas (using portable transmitter)High O 2 readingSamplingFlow rate exceeds limitsPressurized sensorImproper sensor selectionCorrect pressure and flow rateRemove restriction on vent lineReplace <strong>GPR</strong>/PSR sensor with XLT sensor whenCO 2 or acid gases are present31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!