6motor once every 3 months. <strong>Humeca</strong> supplies AesculapSTERILIT ® oil for that purpose.3. Sterilization and clean<strong>in</strong>gTake out the motor. Beware that it doesn’t fall out of the cas<strong>in</strong>g!Attention: Never sterilize the motor !!The entire Micrograft cutt<strong>in</strong>g mach<strong>in</strong>e can be cleaned and steamsterilized, except for the motor. Autoclav<strong>in</strong>g occurs at a commontemperature of 134 o C (usually 5-10 m<strong>in</strong>utes) or 121 o C(prolonged exposure time of approx. 20 m<strong>in</strong>utes).If necessary, clean the blades by hand from sk<strong>in</strong> remnants andblood immediately after use. To that end loose the two screws11 (fig. 1) and lift off the cover 12 of the bridge. Take out theblades axis, clean it with water and a soft brush and replace it <strong>in</strong>the mach<strong>in</strong>e.Attention!!!Never touch the blades with your f<strong>in</strong>gers!They are extremely sharp. Never touch theblades with some hard object nor place themon a hard surface. They’ll be damaged.Also the <strong>in</strong>side of the cutt<strong>in</strong>g block cover has to be cleaned byhand sometimes. Because this surface contacts the sk<strong>in</strong> dur<strong>in</strong>gcutt<strong>in</strong>g, on the long term a sticky layer (biofilm) might be formed.If persistent, this layer has to be removed mechanically by hand.Fig. 20and 20A show how the different parts of the MEEKmach<strong>in</strong>e can be placed <strong>in</strong> the MEEK sterilization case 3.MAC02.If you use a different case, please leave the blades axis <strong>in</strong>position on the mach<strong>in</strong>e dur<strong>in</strong>g wash<strong>in</strong>g and sterilization (asshown <strong>in</strong> fig. 2) <strong>in</strong> order to prevent damage. Alternatively, youcan put the blades axis separately <strong>in</strong> the small sterilization case3.MAC03 (fig. 21) that <strong>Humeca</strong> supplies for this purpose. Thecutt<strong>in</strong>g block 1 and the serrated wedge 17 are placed next to themach<strong>in</strong>e dur<strong>in</strong>g sterilization.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!