POLARIS GC/MS
POLARIS GC/MS
POLARIS GC/MS
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
100<br />
0<br />
100<br />
0<br />
Full scan<br />
EI/<strong>MS</strong><br />
6.7 3<br />
7.57<br />
8.03<br />
6 7 8 9 1 0 1 1<br />
Time (min)<br />
9.30<br />
1 0. 05<br />
1 0.46<br />
6.30 7.1 9 7.7 5<br />
8.4 0<br />
8.9 2<br />
9.86<br />
1 0.54 1 1.06<br />
<strong>MS</strong>/<strong>MS</strong><br />
9.1 4<br />
<strong>POLARIS</strong><br />
Collect full scan and <strong>MS</strong>/<strong>MS</strong> data simultaneously<br />
9.30<br />
Mevinphos<br />
Mevinphos<br />
(parent ion - m/z 192)<br />
1 0. 06<br />
9 .58 1 0.39<br />
1 1.05<br />
8 0 1 0 0 1 2 0 1 4 0 1 6 0 1 8 0 2 0 0<br />
Simultaneous full scan and <strong>MS</strong>/<strong>MS</strong> allows accurate quantitative and qualitative analysis of target compounds<br />
and unknown compounds.<br />
10 0<br />
0<br />
100<br />
0<br />
Full scan<br />
EI/<strong>MS</strong><br />
109.1<br />
127.0<br />
m / z<br />
1 6 4 .1<br />
1 9 2.1<br />
78.9 160.1 19 2.8<br />
85. 1 99.0<br />
110.1<br />
149. 1<br />
164.8<br />
194.1<br />
<strong>MS</strong>/<strong>MS</strong><br />
10 2.1<br />
109.1<br />
11 3. 0<br />
127.0<br />
13 5 .1<br />
14 9 .1<br />
1 5 9.9<br />
1 6 4.0<br />
1 6 4.8<br />
key applications:<br />
• Arson<br />
• Pesticide residue<br />
• Sports testing<br />
<strong>GC</strong>/<strong>MS</strong>/<strong>MS</strong> is a target analysis<br />
technique, so you must know what<br />
you are looking for in the sample.<br />
However, full scan EI/<strong>MS</strong> analysis<br />
allows the chromatographer to<br />
measure any compound that might be<br />
present in the sample provided that<br />
the concentration is sufficient and the<br />
matrix is not too intense in that part<br />
of the chromatogram. As you can well<br />
imagine a combination of full scan and<br />
<strong>MS</strong>/<strong>MS</strong> would be very powerful. The<br />
full scan chromatogram can be used to<br />
identify and quantitate compounds<br />
that are not on the target analyte list,<br />
while the <strong>MS</strong>/<strong>MS</strong> chromatogram<br />
provides very accurate low level<br />
quantitation for the selected analytes.<br />
Our new Xcalibur software gives the<br />
analyst the ability to collect full scan<br />
and <strong>MS</strong>/<strong>MS</strong> data simultaneously. How<br />
is this possible? Polaris combines its<br />
rapid scan speed with the powerful<br />
Xcalibur software which collects and<br />
separates the data appropriately.<br />
Quantitative and qualitative analysis is<br />
both accurate and reliable. This<br />
reduces analysis time, enhances data<br />
quality and maximizes productivity.