30.11.2012 Views

POLARIS GC/MS

POLARIS GC/MS

POLARIS GC/MS

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

100<br />

0<br />

100<br />

0<br />

Full scan<br />

EI/<strong>MS</strong><br />

6.7 3<br />

7.57<br />

8.03<br />

6 7 8 9 1 0 1 1<br />

Time (min)<br />

9.30<br />

1 0. 05<br />

1 0.46<br />

6.30 7.1 9 7.7 5<br />

8.4 0<br />

8.9 2<br />

9.86<br />

1 0.54 1 1.06<br />

<strong>MS</strong>/<strong>MS</strong><br />

9.1 4<br />

<strong>POLARIS</strong><br />

Collect full scan and <strong>MS</strong>/<strong>MS</strong> data simultaneously<br />

9.30<br />

Mevinphos<br />

Mevinphos<br />

(parent ion - m/z 192)<br />

1 0. 06<br />

9 .58 1 0.39<br />

1 1.05<br />

8 0 1 0 0 1 2 0 1 4 0 1 6 0 1 8 0 2 0 0<br />

Simultaneous full scan and <strong>MS</strong>/<strong>MS</strong> allows accurate quantitative and qualitative analysis of target compounds<br />

and unknown compounds.<br />

10 0<br />

0<br />

100<br />

0<br />

Full scan<br />

EI/<strong>MS</strong><br />

109.1<br />

127.0<br />

m / z<br />

1 6 4 .1<br />

1 9 2.1<br />

78.9 160.1 19 2.8<br />

85. 1 99.0<br />

110.1<br />

149. 1<br />

164.8<br />

194.1<br />

<strong>MS</strong>/<strong>MS</strong><br />

10 2.1<br />

109.1<br />

11 3. 0<br />

127.0<br />

13 5 .1<br />

14 9 .1<br />

1 5 9.9<br />

1 6 4.0<br />

1 6 4.8<br />

key applications:<br />

• Arson<br />

• Pesticide residue<br />

• Sports testing<br />

<strong>GC</strong>/<strong>MS</strong>/<strong>MS</strong> is a target analysis<br />

technique, so you must know what<br />

you are looking for in the sample.<br />

However, full scan EI/<strong>MS</strong> analysis<br />

allows the chromatographer to<br />

measure any compound that might be<br />

present in the sample provided that<br />

the concentration is sufficient and the<br />

matrix is not too intense in that part<br />

of the chromatogram. As you can well<br />

imagine a combination of full scan and<br />

<strong>MS</strong>/<strong>MS</strong> would be very powerful. The<br />

full scan chromatogram can be used to<br />

identify and quantitate compounds<br />

that are not on the target analyte list,<br />

while the <strong>MS</strong>/<strong>MS</strong> chromatogram<br />

provides very accurate low level<br />

quantitation for the selected analytes.<br />

Our new Xcalibur software gives the<br />

analyst the ability to collect full scan<br />

and <strong>MS</strong>/<strong>MS</strong> data simultaneously. How<br />

is this possible? Polaris combines its<br />

rapid scan speed with the powerful<br />

Xcalibur software which collects and<br />

separates the data appropriately.<br />

Quantitative and qualitative analysis is<br />

both accurate and reliable. This<br />

reduces analysis time, enhances data<br />

quality and maximizes productivity.