Hazardous areaSafe area<strong>BA427E</strong>4/<strong>20mA</strong> <strong>manual</strong><strong>set</strong> <strong>point</strong> <strong>station</strong>[<strong>set</strong> <strong>point</strong> generator]4/<strong>20mA</strong>Zener barriers orgalvanic isolators4/<strong>20mA</strong>Speedcontroller+Intrinsically safe for usein all gas and dusthazardous areasu Loop poweredShown with optional loop powered backlightThe <strong>BA427E</strong> is an intrinsically safe panelmounting <strong>set</strong> <strong>point</strong> <strong>station</strong> that enables thecurrent flowing in a 4/<strong>20mA</strong> loop to be<strong>manual</strong>ly adjusted via the front panel pushbuttons from within the hazardous area. It isa second generation instrument that ismechanically and electrically compatiblewith the earlier BA405C, but has moredisplay digits plus additional functions.Main application of the <strong>BA427E</strong> is theadjustment of a 4/<strong>20mA</strong> plant parameterfrom within a hazardous area. For example,used as the remote <strong>set</strong> <strong>point</strong> generator for aspeed controller the <strong>BA427E</strong> enables speedadjustments from within the hazardousprocess area. The <strong>BA427E</strong> may also beused to position an actuator or valve with a4/<strong>20mA</strong> input. The <strong>BA427E</strong> incorporates afive digit display plus a bargraph that maybe calibrated to show the engineering unitsrepresented by the 4/<strong>20mA</strong> current, allowingan operator to easily <strong>set</strong> the processvariable to the required value.International intrinsic safety certificationpermits the <strong>BA427E</strong> to be installed throughoutthe world. All input safety parameters are thesame or greater than those for the precedingBA405C, thus allowing the <strong>BA427E</strong> to safelyreplace the earlier model.Five pre-<strong>set</strong> output values may be rapidlyselected using the instrument’s front panelpush buttons for applications where thesame output values are repeatedly required.To minimise plant disturbance when theoutput is adjusted or switched betweenpre-<strong>set</strong>s, the maximum rate of output currentchange may be defined. The 4/<strong>20mA</strong> outputrange may also be restricted so thatoperators can only adjust the plant variablewithin safe limits.The bold 11mm high liquid crystal displayprovides maximum contrast and has a verywide viewing angle, allowing the <strong>BA427E</strong><strong>set</strong> <strong>point</strong> <strong>station</strong> display to be read easily inmost lighting conditions over a widetemperature range. The five digits, with fourdecimal <strong>point</strong>s and a negative sign, may beconfigured to display any variablerepresented by the 4/<strong>20mA</strong> output currentbetween -99999 and 99999.Engineering units represented by the4/<strong>20mA</strong> output current are shown on thescale card viewed through a window on theright hand side of the display. If the units arespecified when the <strong>BA427E</strong> is ordered aprinted scale card will be fitted. If units are notspecified, a blank card will be supplied whichcan easily be marked and installed on-sitewithout dismantling the <strong>set</strong> <strong>point</strong> <strong>station</strong>enclosure or removing it from the panel.Display backlighting which may be loop orseparately powered is available as a factoryfitted option. It provides green backgroundillumination allowing the display to be readat night or in poorly illuminated areas. Whenpowered from the 4/<strong>20mA</strong> loop no additionalintrinsically safe interface or wiring isrequired. Powering from a separate supplyproduces a brighter backlight but requiresan additional intrinsically safe interface andfield wiring. Two backlights may beseparately powered from one intrinsicallysafe interface.IP66 front panel protection and a neoprenegasket to seal the joint between the <strong>set</strong> <strong>point</strong><strong>station</strong> and the panel make the instrumentsuitable for use in areas that will be cleanedwith a hose. To simplify installation andmaintenance, the <strong>set</strong> <strong>point</strong> <strong>station</strong> has aremovable terminal block allowing panel wiringto be completed before the <strong>BA427E</strong> isinstalled.A BA490 panel mounting external rotaryencoder may be directly connected to the<strong>BA427E</strong> <strong>set</strong> <strong>point</strong> <strong>station</strong> to provide analoguecontrol of the output current. The encodercomplies with the requirements for SimpleAparatus and can be installed in the samehazardous area as the <strong>set</strong> <strong>point</strong> <strong>station</strong>.Reliability is ensured by componentconformal coating, protection from incorrectconnection and radio frequency interference.The <strong>set</strong> <strong>point</strong> <strong>station</strong> has been subjected tovibration testing and is supported by a threeyear guarantee.0u Intrinsically safeATEX, IECExETL & cETL.u 5 digit 11mm highdisplay & 31 segmentbargraph.u Optional backlight &BA490 external rotaryencoder.u IP66 frontu Easy on-site scalecard installation.u 96 x 48mm DINenclosure.u 3 year guaranteewww.beka.co.uk/ba427e<strong>BEKA</strong> associates Ltd. Old Charlton Rd.Hitchin, Hertfordshire, SG5 2DA, U.K.Tel. (01462) 438301 Fax (01462) 453971e-mail sales@beka.co.uk www.beka.co.uk


SPECIFICATION DIMENSIONS (mm)OutputCurrentResistance3.0 to 22.0mAGreater than 1MΩRecommended panel cut-outPower supplyVoltageAccuracyControl resolutionTemperature effect6.1 to 30V10 to 30V when optional backlight isloop powered.1 least significant digit of the display, or 0.3µAwhichever is greater.Less than 2µA/°CPanel cut-outTo achieve an IP66 seal betweenthe instrument and the panel90 +0.5 / -0.0 x 43.5 +0.5 / -0.0DIN 43 70092.0 +0.8 / -0.0 x 45 +0.6 / -0.0DisplayType Liquid crystal, non-multiplexed 5 digit 11mmhigh with 31 segment bargraph.Zero Adjustable between 0 & ±99999 with 4mAoutput.Span Adjustable between 0 & ±99999 with <strong>20mA</strong>output.65Decimal <strong>point</strong>Zero blankingDirection1 of 4 positions or absentBlanked apart from 0 in front of decimal <strong>point</strong>.Display may increase or decrease withincreasing 4/<strong>20mA</strong> output.967.5Push buttons(Function in operating mode)‘E’ and ▼ or ▲Scrolls output current down or up▼Shows display calibration with 4mA output.▲Shows display calibration with <strong>20mA</strong> output.‘P’ Displays output current in mA, as a % of spanor provides access to pre-<strong>set</strong> outputs.Set <strong>point</strong> Station <strong>BA427E</strong>Scalecard48Terminals foroptional backlightare shown in outlineIntrinsic safetyEurope ATEXCodeGroup II Category 1GDEx ia IIC T5 GaEx ia IIIC T80°C Da IP20Tamb = -40 to 70°CTERMINAL CONNECTIONSInput parametersUi30V dcIi200mAPi 0.84WCert. No.International IECExCodeCert. NoITS12ATEX27718X(Special conditions only apply for use inGroup IIIC conductive dusts)Ex ia IIC T5 GaEx ia IIIC T80°C Da IP20Tamb = -40 to 70°CIECEx ITS12.0084X(Special conditions only apply for use inGroup IIIC conductive dusts)USA ETLStandards ANSI/ISA 60079-0 &11 conforms to UL 9137th edition & UL 60079-0 & 11.IS Code IS CL I, Div 1, GP A, B, C, & D:CL I, ZN 0, AEx ia IIC T5 Ga.NI CodeFile 4008610Canada cETLFile 4008610NI CL I, DIV 2, GP A, B, C & D: CL II,DIV 2, GP E, F & G: CL III, T5.CL I, ZN 2, GP IIA, IIB, IIC, T5 Ta = 70°CEnvironmentalOperating temp -40 to 70°CStorage temp -40 to 85°CHumidityTo 95% at 40°C noncondensingVibrationReport availableEnclosureFront IP66, rear IP20EMCComplies with 2004/108/ECMechanicalTerminalsWeightScrew clamp for 0.5 to 1.5mm² cable,removable.0.2kgAccessoriesBacklightGreen, may be loop or separately powered.Loop powered Set <strong>point</strong> <strong>station</strong> + backlight supply 10 to 30V.Separately powered 9 to 30V at 22mA from IS interface12 13 14+ - - SeparatelypoweredLoop poweredCommonTerminals foroptional backlightPrinted scale cardTag legendBA490 rotary encoderHOW TO ORDER5 6 7ABCommonTerminals foroptional externalrotary encoder1 2 3 4+4/<strong>20mA</strong>Terminals 2 & 4 areinternally linked forjoining return4/<strong>20mA</strong> wirePlease specifyModel number<strong>BA427E</strong>Display at:4.000mAXXXXX Include position of20.000mA XXXXX decimal <strong>point</strong> & sign if negative *AccessoriesDisplay backlightScale cardTagExternal rotary encoderBlank card fitted to each Set Point Station canbe supplied type<strong>set</strong> with specified engineeringunits.Specified tag number or application thermallyprinted onto rear of the instrument.Panel mounting IP65 sealed rotary encoderwhich provides analogue control of the<strong>BA427E</strong> output current. Complies with therequirements for Simple Apparatus.See separate datasheet.Please specify if requiredBacklightLegend requiredLegend requiredBA490* Will be <strong>set</strong> to display 0.00 at 4mA output and 100.00 at <strong>20mA</strong> output if calibrationinformation is not supplied. Calibration can easily be changed on-site.02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!