<strong>BA508E</strong>2-<strong>wire</strong> 4/<strong>20mA</strong>4 <strong>digit</strong> <strong>indicator</strong>General purposeu Loop powered only1.2V drop.2-<strong>wire</strong>Tx4/<strong>20mA</strong>4/<strong>20mA</strong>circuitu 4 <strong>digit</strong> 34mm highdisplay.The <strong>BA508E</strong> loop powered 4/<strong>20mA</strong><strong>indicator</strong> is a fourth generationinstrument that is electrically andmechanically compatible with the earlierBA508C, but has a much larger full 4 <strong>digit</strong>display providing maximum visibility from a144 x 72mm instrument. The new modelhas guaranteed performance between -40& 70˚C, and an even shorter enclosuredepth than its predecessor. The scale cardcan easily be marked to show the units ofmeasurement and can be installed on-sitewithout dismantling the <strong>indicator</strong> enclosureor removing the <strong>indicator</strong> from the panel. Ifthe units of measurement are not specifiedwhen the <strong>indicator</strong> is ordered, a blankscale card will be fitted.The main application of the <strong>BA508E</strong> is todisplay a measured variable in meaningfulengineering units within a process area.The zero and span of the display areindependently adjustable allowing the<strong>indicator</strong> to be calibrated to display anylinear variable represented by the 4/<strong>20mA</strong>signal. A root extractor and an adjustablesixteen segment lineariser enables the<strong>indicator</strong> to display flow and variables suchas tank level in linear engineering units.For weighing applications a tare function isincluded.The bold 34mm high 4 <strong>digit</strong> displayprovides maximum contrast and has avery wide viewing angle, allowing the<strong>BA508E</strong> <strong>indicator</strong> to be easily read in mostlighting conditions over a widetemperature range. An optional factoryfitted backlight is available for applicationsin poorly illuminated areas. The five <strong>digit</strong>s,with four decimal points and a negativesign, may be configured to display anyvariable between -9999 and 9999.IP66 front panel protection and aneoprene gasket to seal the joint betweenthe <strong>indicator</strong> and the panel make theinstrument suitable for use in areas thatwill be cleaned with a hose. To simplifyinstallation and maintenance, the <strong>indicator</strong>has a removable terminal block allowingpanel wiring to be completed before the<strong>BA508E</strong> <strong>indicator</strong> is installed.A backlight which may be loop orseparately powered is available as afactory fitted option. It provides greenbackground illumination allowing thedisplay to be read at night or in poorlyilluminated areas. When powered from the4/<strong>20mA</strong> loop no additional field wiring isrequired. Powering from a separate supplyproduces a brighter backlight but requiresadditional field wirings.Optional dual alarm outputs which canswitch low power loads, such as sounders,beacons and solenoid valves, are availableas a factory fitted option. The twogalvanically isolated solid state outputsmay be independently conditioned as highor low alarms with normally open or closedoutputs. Annunciators on the display showthe status of both alarm outputs.Reliability is ensured by componentconformal coating, protection fromincorrect connection and radio frequencyinterference. The <strong>indicator</strong> has beensubjected to vibration testing and issupported by a three year guarantee.Other models in this range include theBA528E which has a similar specificationwith five 29mm high <strong>digit</strong>s and a 31segment bargraph.If flammable atmospheres are presentthe BA308E should be used. This has thesame features as the <strong>BA508E</strong> but hasbeen certified for use in hazardous areasu Optional backlight &alarms.u Easy on-site scalecard installation.u IP66 frontu Root extractor and16 segment lineariser.u 144 x 72mmDIN enclosure.u 3 year guaranteewww.beka.co.uk/ba508e<strong>BEKA</strong> associates Ltd. Old Charlton Rd.Hitchin, Hertfordshire, SG5 2DA, U.K.Tel. (01462) 438301 Fax (01462) 453971e-mail sales@beka.co.uk www.beka.co.uk


SPECIFICATION DIMENSIONS (mm)InputCurrent4 to <strong>20mA</strong>Voltage Less than 1.2V at 20°CLess than 1.3V at -40°CLess than 5V with optional looppowered backlight.Overrange±200mA or ±30V will not damage the<strong>indicator</strong>.Panel cut-outRecommended panel cut-outDIN 43 700138.0 +1.0/ -0.0 x 68.0 +0.7/ -0.0To achieve an IP66 seal betweenthe instrument and the panel136.0 +0.5/-0.0 x 66.2 +0.5/-0.0Four panel mounting clips mustbe usedDisplayTypeSpanZeroDecimal pointPolarityZero blankingDirectionReading rateOverangeLiquid crystal, non-multiplexed 4 <strong>digit</strong>s34mm high.Adjustable between 0 & ±9999 for a4/<strong>20mA</strong> input.Adjustable between 0 & ±9999 with 4mAinput.1 of 3 positions or absentAutomatic minus signBlanked apart from 0 in front of decimalpoint.Display may increase or decrease withincreasing 4/<strong>20mA</strong> input.2 per second9999 or -9999 with all decimal pointsflashing.144<strong>BA508E</strong>Scalecard657.572Terminals for optionalbacklight and alarmsare shown in outlinePush buttons(Function in display mode)▼Shows display with 4mA input▲Shows display with <strong>20mA</strong> input‘P’ Displays input in mA or a % of span,has a modified function when alarmsare fitted.‘E’Used for tare functionTERMINAL CONNECTIONSAccuracy at 20°CLinearTemperature effect on:ZeroSpanSeries mode rejection±0.02% of span ±1 <strong>digit</strong>.Root extracting ±16µA at input ±1 <strong>digit</strong>.Less than 25ppm of span/°CLess than 50ppm of span/°CLess than 0.05% of span error for 1mApk to pk 50 or 60Hz interference.EnvironmentalOperating temp -40 to 70°CStorage temp -40 to 85°CHumidityto 95% at 40°C noncondensing.VibrationReport availableEnclosureFront IP66, rear IP20EMCComplies with 2004/108/EC1 2 3 4+4/<strong>20mA</strong>Terminals 2 & 4 areinternally linked forjoining return4/<strong>20mA</strong> <strong>wire</strong>Printed scale cardPack of printedscale cardsTag legend8 9 10 11 12 13 14+ - + - +Alarm 1 Alarm 2Terminals foroptional alarms- - SeparatelypoweredLoop poweredCommonTerminals foroptional backlightBlank card fitted to each Indicator canbe supplied typeset with specified unitsof measurement.Contains 26 common units ofmeasurement and four blanks.Specified tag number or applicationthermally printed onto rear of theinstrument.MechanicalTerminalsWeightAccessoriesBacklightLoop poweredSeparately poweredV supplyI inAlarmsOutputVmaxImaxRonRoffScrew clamp for 0.5 to 1.5mm ² cable,removable.0.35kgGreen, may be loop or separatelypowered.Indicator input voltage 5V11V to 30V dc35mATwo alarm outputs each of which maybe independently configured as a highor low alarm contact with a NO or NCoutput.Isolated solid state switch40V dc200mA5Ω + 0.7V max1MΩ minHOW TO ORDERModel numberDisplay modeDisplay at:4.000mA20.000mAAccessoriesDisplay backlightDual alarmsScale cardTagPlease specify<strong>BA508E</strong>Linear, root or lineariser*XXXX Include position of decimal point,*XXXX sign if negative & intermediatepoints if lineariser is required.Please specify if requiredBacklightAlarmsLegend requiredLegend required* Will be set to display 0.0 at 4mA and 100.0 at <strong>20mA</strong> with a lineardisplay if calibration information is not supplied. Can easily berecalibrated on-site.03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!