12.07.2015 Views

Honeywell ST 3000 Smart Pressure - Lesman Instrument Company

Honeywell ST 3000 Smart Pressure - Lesman Instrument Company

Honeywell ST 3000 Smart Pressure - Lesman Instrument Company

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

34-<strong>ST</strong>-03-65Page 6Performance Under Rated Conditions* - Model <strong>ST</strong>D974 (0 to <strong>3000</strong> psi/210 bar)ParameterUpper Range LimitMinimum Spanpsibarpsibar<strong>3000</strong>2101007Turndown Ratio 30 to 1Zero Elevation and SuppressionAccuracy (Reference – Includescombined effects of linearity,hysteresis, and repeatability)• Accuracy includes residual errorafter averaging successivereadings.• For FOUNDATION Fieldbus useDigital Mode specifications. ForHART use Analog Modespecifications.Zero Temperature Effect per28°C (50°F)Combined Zero and SpanTemperature Effect per 28°C(50°F)Zero Static <strong>Pressure</strong> Effect per1000 psi (70 bar)Combined Zero and Span Static<strong>Pressure</strong> Effect per 1000 psi (70bar)–0.6 and +100% URL.DescriptionIn Analog Mode: ±0.2% of calibrated span or upper range value (URV), whichever isgreater, terminal based.For URV below reference point (300 psi), accuracy equals:±0.05 + 0.15 (300 psi) span psior ±0.05+ 0.15 (21 barspan bar )in % spanIn Digital Mode: ±0.175% of calibrated span or upper range value (URV), whicheveris greater, terminal based.For URV below reference point (300 psi), accuracy equals:±0.025 + 0.15 (300 psi) span psior ±0.025+ 0.15 (21 barspan bar )In Analog Mode: ±0.2125% of span.For URV below reference point (500 psi), effect equals:±0.0125 + 0.20 (500 psi) span psior ±0.0125 + 0.20 (35 barspan bar )In Digital Mode: ±0.20% of span.For URV below reference point (500 psi), effect equals:±0.20 (500 psi) span psior ±0.20 (35 barspan bar )in % spanIn Analog Mode: ±0.325% of span.For URV below reference point (500 psi), effect equals:±0.125 + 0.20 (500 psi) span psior ±0.125 + 0.20 (35 barspan bar )In Digital Mode: ±0.30% of span.For URV below reference point (500 psi), effect equals:±0.10 + 0.20 (500 psi) span psior ±0.10 + 0.20 (35 barspan bar )±0.1625% of span.For URV below reference point (500 psi), effect equals:±0.0125 + 0.15 (500 psi) span psior ±0.0125 + 0.15 (35 barspan bar )±0.30% of span.For URV below reference point (500 psi), effect equals:±0.15 + 0.15 (500 psi) span psior ±0.15 + 0.15 (35 barspan bar )in % spanin % spanin % spanin % spanin % spanin % spanStability±0.03% of URL per year* Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and316L Stainless Steel barrier diaphragm.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!