402.5 Discharge Risers. When plastic pipe is utilized for the pump dischargeriser and the riser exceeds 12 foot in length, a stainless steel support brace must be installedbetween the riser and wet well wall. <strong>The</strong> brace shall be placed approximately on the middle <strong>of</strong>the riser but kept above the normal operating level <strong>of</strong> the well. Two (2) braces will be neededon lengths in excess <strong>of</strong> 20 feet.402.6 Gate and Check Valves.a. Gate valves: Gate valves shall be ductile iron body resilient seated gate valvesconform to AWWA C509 (latest revision), Resilient-Seated Gate Valves for WaterSupply Service. <strong>The</strong> gate valve shall be <strong>of</strong> the non-rising stem, open left(counterclockwise), bronze stem type. <strong>The</strong> interior and exterior surfaces shall becoated using a fusion epoxy, 10 mil thickness. Epoxy shall meet or exceedANSI/AWWA C550 Standard, and certified to ANSI/NSF 61.. Valve operatorsshall be by manufacturer’s standard hand wheel. All valve hardware, stemextensions and guides shall be stainless steel.Acceptable manufacturer and model: Mueller Co., Series 2360, or approvedequal.b. Check valves: Check valves shall be full body flanges type, with a domedaccess cover and only one moving part, the flexible disc, conforming to AWWAC508 (latest revision), Swing-Check Valves for Waterworks Service, 2 inch (50mm) Through 24 inch (600 mm) NPS.<strong>The</strong> valve body shall have full flow equal to nominal pipe diameter at all pointsthrough the valve. <strong>The</strong> seating surface shall be on a 45-degree angle tominimize disc travel. A threaded port with pipe plug shall be provided on thebottom <strong>of</strong> the valve to allow for field installation <strong>of</strong> a backflow actuator withoutspecial tools or removing the valve from the line.<strong>The</strong> top access port shall be full size, allowing removal <strong>of</strong> the disc withoutremoving the valve from the line. <strong>The</strong> access cover shall be domed in shape toprovide flushing action over the disc for operation in lines containing high solidscontent. <strong>The</strong> disc shall be <strong>of</strong> one-piece construction, precision molded with anintegral o-ring type-sealing surface, and contain steel and nylon reinforcement inthe hinge. <strong>The</strong> flex portion <strong>of</strong> the disc shall be warranted for 25 years. Non-slamclosing characteristics shall be provided through a short 35-degree disc strokeand a memory disc return action.<strong>The</strong> valve body shall be construction <strong>of</strong> ASTM A126 Call B cast iron. Optionalbody material includes ASTM A536 Grade 65-45-12 ductile iron. <strong>The</strong> disc shallbe precision molded Buna-N (NBR), ASTM D2000-BG.Valves shall be provided with flanges in accordance with ANSI B16.1, Class 125.<strong>The</strong> interior and exterior surfaces shall be coated using a fusion epoxy, 10 milthickness. Epoxy shall meet or exceed ANSI/AWWA C550 Standard, andcertified to ANSI/NSF 61.400 - 6<strong>City</strong> <strong>of</strong> <strong>Wentzville</strong>Construction Specifications and Standard DetailsEffective Date: 06/10/09

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!